Biologically-based modeling insights in inhaled vapor absorption and dosimetry.

Pharmacol Ther

Toxicology Program, Department of Pharmaceutical Sciences, School of Pharmacy, University of Connecticut, Storrs, CT, USA.

Published: December 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The lung is a route of entry and also a target site for inhaled vapors, therefore, knowledge of the total absorbed dose and/or the dose absorbed in each airway during inhalation exposure is essential. Vapor absorption characteristics result primarily from the fact that vapors demonstrate equilibrium/saturation behavior in fluids. Thus, during inhalation exposures blood and airway tissue vapor concentrations increase to a steady state value and increase no further no matter how long the exposure. High tissue concentrations can be obtained with highly soluble vapors, thus solubility, as measured by blood:air partition coefficient, is a fundamentally important physical/chemical characteristic of vapors. While it is classically thought that vapor absorption occurs only in the alveoli it is now understood that this is not the case. Soluble vapors can be efficiently absorbed in the airways themselves and do not necessarily penetrate to the alveolar level. Such vapors are more likely to injure the proximal than distal airways because that is the site of the greatest delivered dose. There are substantial species differences in airway vapor absorption between laboratory animals and humans making interpretation of laboratory animal inhalation toxicity data difficult. Airway absorption is dependent on vapor solubility and is enhanced by local metabolism and/or direct reaction within airway tissues. Modern simulation models that incorporate terms for solubility, metabolism, and reaction rate accurately predict vapor absorption patterns in both animals and humans and have become essential tools for understanding the pharmacology and toxicology of airborne vapors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pharmthera.2012.08.017DOI Listing

Publication Analysis

Top Keywords

vapor absorption
20
soluble vapors
8
animals humans
8
vapor
7
vapors
7
absorption
6
airway
5
biologically-based modeling
4
modeling insights
4
insights inhaled
4

Similar Publications

On-site mercury analyser employing enclosed quartz cell cold vapour atomic absorption spectrometry and 3D printing techniques.

Talanta

September 2025

Department of Chemistry and Biotechnology, Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-cho, Kochi City, Kochi, 780-8520, Japan. Electronic address:

The development of on-site Hg analysers is crucial for the rapid evaluation of Hg concentrations in environmental research. However, the fabrication of Hg analysers requires simplification of analytical procedures and device miniaturisation. Based on the above requirements, our research group previously investigated enclosed quartz cell cold vapour atomic absorption spectrometry (EQC-CV-AAS) as a base technique for an on-site Hg analyser.

View Article and Find Full Text PDF

Titanium dioxide (TiO) thin films were deposited on glass substrates under HV conditions at room temperature by the physical vapor deposition method. Produced titanium thin films were post-annealed at 573 K at different oxygen flows (0, 9 and 23 cm/s). The influence of different oxygen flows on nano-structure, crystallography, and optical parameters of TiO films was investigated by XRD, AFM, and spectrophotometer in the UV-VIS wavelength range.

View Article and Find Full Text PDF

Purpose: To report two cases of macular exudations resulting from retinal arterial macroaneurysms (MaAs) refractory to focal photocoagulations that were treated with a new surgical technique including subretinal balanced saline solution (BSS) injection to dilute lipid-rich subretinal fluid (SRF) and facilitate absorption of the SRF, intentional retinal hole formation to direct SRF into the vitreous cavity, and laser photocoagulation posterior to the MaAs to prevent intraretinal fluid and SRF from reaching the fovea.

Observations: A 70-year-old man with macular edema (ME) refractory to anti-vascular endothelial growth factor (VEGF) therapy was referred to our hospital. Fundus examination showed retinal arterial MaAs and hard exudations.

View Article and Find Full Text PDF

This study reports the enhanced photoelectrochemical (PEC) performance of TiO/α-FeO heterostructure films fabricated a sequential aerosol-assisted chemical vapour deposition (AACVD) of hematite at 450 °C, followed by atmospheric pressure CVD (APCVD) of anatase TiO with controlled thickness. Structural analyses (XRD, Raman, XPS) confirmed phase purity and oxidation states, while UV-vis spectroscopy revealed a narrowed bandgap and extended visible light absorption for the heterostructures compared to pristine films. The optimized TiO/α-FeO (8 min) photoanode achieved a photocurrent density of 1.

View Article and Find Full Text PDF

Surface-enhanced Raman spectroscopy (SERS) by 2D semiconductors relies on chemical (CM) enhancement driven by charge-transfer (CT) processes in bandgap alignment between molecules and substrates. Unfortunately, the low light absorption and weak conferment in the atomic-layer material limit the enhancement factor of Raman intensity (EFRI). Improving the utilization efficiency of excitation light is therefore essential for promoting SERS performance of 2D semiconductors.

View Article and Find Full Text PDF