Reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound.

J Ultrasound Med

Department of Medicine, Division of Experimental Medicine, Faculty of Medicine, Imperial College London, Hammersmith Hospital, Du Cane Road, London W12 0NN, England.

Published: September 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The aim of this clinical study was to evaluate the reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound.

Methods: Fifteen patients with colorectal liver metastases and 5 volunteers were studied. The hepatic artery proper and the portal vein were imaged simultaneously with dynamic contrast-enhanced ultrasound. The examination was repeated with 2 different contrast bolus volumes (1.2 and 2.4 mL), and time-intensity curves were formed from dynamic contrast-enhanced ultrasound image loops. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Inter-reader, intra-reader, and inter-scan agreement was assessed by 2 independent readers. Quantitative (intraclass correlation coefficients and coefficients of variation [CVs]) and qualitative (Landis and Koch classification) analyses were performed.

Results: Intra-reader and inter-reader agreement was "almost perfect" for the hepatic artery (CV, 10%-15% and 8%-9%, respectively), portal vein (CV, 5%-8% and 6%-12%), and hepatic artery/portal vein ratio (CV, 8%-14% and 10%-15%) measurements of 3 all studied parameters. In contrast, inter-scan agreement was only "slight" to "moderate" (CV, 25%-27%) and "fair" to "moderate" (CV, 19%-24%) for rise time and peak intensity measurements in the hepatic artery and portal vein, respectively.

Conclusions: Quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound is reproducible provided that measurements in the hepatic artery are normalized by those in the portal vein.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2012.31.9.1413DOI Listing

Publication Analysis

Top Keywords

dynamic contrast-enhanced
20
hepatic artery
20
portal vein
20
contrast-enhanced ultrasound
16
quantitative assessment
12
assessment altered
12
altered hepatic
12
hepatic hemodynamics
12
hemodynamics dynamic
12
hepatic
9

Similar Publications

Aims: Cardiac tumors are aggressive and asymptomatic in early stages, causing late diagnosis and locoregional metastasis. Currently, the standard of care uses gadolinium-based contrast agents for MRI, and the associated hypersensitivity reactions are a significant concern, such as gadolinium deposition disease. In addition, the proximity of cardiac lesions closer to vital structures complicates surgical interventions.

View Article and Find Full Text PDF

Purpose: Gadoxetic acid-enhanced hepatobiliary phase T-weighted (Tw) MRI is effective for the detection of focal liver lesions but lacks sufficient T contrast to distinguish benign from malignant lesions. Although the addition of T, diffusion, and dynamic contrast-enhanced Tw imaging improves lesion characterization, these methods often do not provide adequate spatial resolution to identify subcentimeter lesions. This work proposes a high-resolution, volumetric, free-breathing liver MRI method that produces colocalized fat-suppressed, variable Tw images from a single acquisition, thereby improving both lesion detection and characterization.

View Article and Find Full Text PDF

Background: Azygos vein aneurysm (AVA) is a rare thoracic pathology that is frequently misdiagnosed. While contrast-enhanced chest computed tomography (CT) or magnetic resonance imaging (MRI) can delineate AVA location and size, these techniques lack the capability for dynamic real-time assessment of internal architecture.

Case Presentation: We present a highly unusual case of a 67-year-old woman who had an isolated azygos vein aneurysm presenting with dysphagia.

View Article and Find Full Text PDF

Glioblastoma is characterized by aggressive infiltration into surrounding brain tissue, hindering complete surgical resection and contributing to poor patient outcomes. Identifying tumor-specific invasion patterns is essential for advancing our understanding of glioblastoma progression and improving surgical and radiotherapeutic strategies. Here, we leverage in vivo dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to noninvasively quantify interstitial fluid velocity, direction, and diffusion within and around glioblastomas.

View Article and Find Full Text PDF

Adrenal capillary hemangiomas are an extremely rare tumor type, and no previous studies have described their features using dynamic contrast-enhanced computed tomography. We report the case of a 65-year-old male patient with a history of right partial nephrectomy for renal clear cell carcinoma. During follow-up, computed tomography scans revealed growth of a right adrenal nodule.

View Article and Find Full Text PDF