Miniature implantable antennas for biomedical telemetry: from simulation to realization.

IEEE Trans Biomed Eng

School of Electrical and Computer Engineering and the Institute of Communications and Computer Systems, National Technical University of Athens, Athens 15780, Greece.

Published: November 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We address numerical versus experimental design and testing of miniature implantable antennas for biomedical telemetry in the medical implant communications service band (402-405 MHz). A model of a novel miniature antenna is initially proposed for skin implantation, which includes varying parameters to deal with fabrication-specific details. An iterative design-and-testing methodology is further suggested to determine the parameter values that minimize deviations between numerical and experimental results. To assist in vitro testing, a low-cost technique is proposed for reliably measuring the electric properties of liquids without requiring commercial equipment. Validation is performed within a specific prototype fabrication/testing approach for miniature antennas. To speed up design while providing an antenna for generic skin implantation, investigations are performed inside a canonical skin-tissue model. Resonance, radiation, and safety performance of the proposed antenna is finally evaluated inside an anatomical head model. This study provides valuable insight into the design of implantable antennas, assessing the significance of fabrication-specific details in numerical simulations and uncertainties in experimental testing for miniature structures. The proposed methodology can be applied to optimize antennas for several fabrication/testing approaches and biotelemetry applications.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2012.2202659DOI Listing

Publication Analysis

Top Keywords

implantable antennas
12
miniature implantable
8
antennas biomedical
8
biomedical telemetry
8
testing miniature
8
skin implantation
8
fabrication-specific details
8
miniature
5
antennas
5
telemetry simulation
4

Similar Publications

Recent advances of stretchable soft antennas: material, structure and integration.

Nanoscale Horiz

August 2025

State Key Laboratory of Flexible Electronics & Institute of Flexible Electronics, Northwestern Polytechnical University, Xi'an 710129, China.

Stretchable soft antennas represent a transformative class of devices that seamlessly integrate wireless communication into deformable and dynamic platforms. Enabled by advances in functional materials and structural engineering, these antennas can withstand large mechanical deformations while maintaining stable electromagnetic performance - unlocking new possibilities in wearable electronics, soft robotics, and implantable biomedical systems. This review systematically surveys recent progress in conductive material choices - from traditional metals and liquid metal to nanocomposites and hybrid architectures - and examines how structural strategies such as serpentine layouts, kirigami patterns, and out-of-plane designs redistribute strain to preserve antenna performance under repeated deformation.

View Article and Find Full Text PDF

This paper presents a compact wideband implantable antenna developed for wireless capsule endoscopy (WCE) functioning in the 2.4-2.48 GHz ISM band.

View Article and Find Full Text PDF

Decidualization, the process by which endometrial stromal cells differentiate into decidual cells in response to prostaglandin E2 (PGE2) and progesterone receptor (PGR) signaling, is essential for proper implantation and placentation. Primary cilia, microtubule-based cellular antennae, contribute to various differentiation processes, including decidualization. In this study, we demonstrated that both the proportion of ciliated cells and ciliary length increased in a time-dependent manner during in vitro decidualization.

View Article and Find Full Text PDF

Continuous monitoring of vascular stent health is crucial for high-risk patients. Current approaches predominantly rely on inductive coupling, which limits the wireless reading distance and requires precise antenna alignment with implanted stents. Here, we present a long-range wireless electronic system that incorporates a low-resistance inductive stent fabricated via laser micromachining and electroplating of biocompatible metal films, forming a mechanically robust and conductive interface optimized for radar interrogation.

View Article and Find Full Text PDF

A novel dual-band multi-linear polarization reconfigurable (MLPR) antenna for body-centric wireless communication systems (BWCS) is presented in this paper. The design comprises five symmetrically arranged multi-branch radiating units, each integrating an elliptical patch and curved spring branch for the Medical Implant Communication Service (MICS) band (403-405 MHz), and a pair of orthogonal strip patches for the Industrial, Scientific and Medical (ISM) 2.45 GHz band (2.

View Article and Find Full Text PDF