Article Abstract

Intraocular lens (IOL) dislocation is a common complication of phacoemulsification. We describe a technique for retrieving a dislocated IOL using 23-gauge transconjunctival sutureless pars plana vitrectomy and repositioning the IOL in the ciliary sulcus in cases with adequate capsule support. This technique provides the benefits of sutureless surgery despite the complication of a dislocated IOL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2010.12.012DOI Listing

Publication Analysis

Top Keywords

intraocular lens
8
ciliary sulcus
8
sutureless pars
8
pars plana
8
plana vitrectomy
8
dislocated iol
8
repositioning dislocated
4
dislocated intraocular
4
lens ciliary
4
sulcus 23-gauge
4

Similar Publications

Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.

Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation).

View Article and Find Full Text PDF

Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.

Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.

View Article and Find Full Text PDF

Purpose: To compare postoperative vault measurements between horizontal and vertical fixation of the Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) when its size is determined using the KS formula.

Methods: This retrospective study analyzed 2,343 eyes from 1,275 patients who underwent myopic ICL implantation. Pre-operative anterior segment optical coherence tomography (AS-OCT) (CASIA 2; Tomey Corporation) was performed in both horizontal and vertical orientations.

View Article and Find Full Text PDF

Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.

Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).

View Article and Find Full Text PDF

Purpose: To determine the accuracy of a new machine learning-based open-source IOL formula (PEARLS-DGS) in 100 patients who underwent uncomplicated cataract surgery and had a history of laser refractive surgery for myopic defects.

Methods: The setting for this retrospective study was HUMANITAS Research Hospital, Milan, Italy. Data from 100 patients with a history of photorefractive keratectomy or laser in situ keratomileusis were retrospectively analyzed to assess the accuracy of the formula.