98%
921
2 minutes
20
Background: There are currently no standardized three-dimensional (3D) transesophageal echocardiographic (TEE) views of the interatrial septum and atrial septal defects (ASDs). Without a standardized approach, it is difficult to ascertain the important anatomic relationships (such as the location of the aortic rim of an ASD), to perform relevant measurements (such as the size of an ASD or the size of its rims), or to guide the deployment of catheters and devices during atrial septal closure.
Methods: Using a 3D TEE matrix-array transducer, 706 TEE studies were performed over a 14-month period. The purpose of the study was to develop a standardized protocol for anatomically correct orientation of 3D TEE images of the interatrial septum and ASDs.
Results: Among 706 TEE studies, there were 23 patients with ASDs, representing 3.3% of the study population. Eighteen patients had secundum ASDs, two had primum ASDs, and three had sinus venosus ASDs of the superior vena cava type. A protocol for properly orienting 3D TEE images of the interatrial septum and ASDs was developed. When the images are acquired at an angle of 0°, the septum is properly oriented by the tilt-up-then-left maneuver. The initial 3D TEE image in first tilted up to reveal the right atrial side of the septum. Then the image is tilted 180° around its vertical axis to reveal the left atrial side of the septum; the aortic rim is on the left, the superior vena cava on the top, and the right-sided pulmonary vein ostia on the right side of the screen. For acquisitions at a higher angle, the rotate-left-in-z-axis maneuver is used. The image is first tilted up to reveal the right atrial side of the septum, as in the tilt-up-then-left maneuver. The image is then rotated counterclockwise in the z axis until the superior vena cave is at 12 o'clock. Finally, the image is tilted 180° around its vertical axis to reveal the left atrial side of the septum.
Conclusions: The use of standardized tilt-up-then-left and rotate-left-in-z-axis maneuvers enhances the diagnosis of ASDs, ascertains the important anatomic relationships of ASDs to surrounding structures, and facilitates communication between echocardiographers obtaining 3D TEE images and interventional cardiologists or cardiac surgeons performing ASD closures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2010.08.008 | DOI Listing |
J Synchrotron Radiat
November 2025
Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA.
Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on.
View Article and Find Full Text PDFJ R Soc Interface
September 2025
Institute of Intelligent Systems and Robotics, Sorbonne Université, Paris, Île-de-France, France.
A number of techniques have been developed to measure the three-dimensional trajectories of protists, which require special experimental set-ups, such as a pair of orthogonal cameras. On the other hand, machine learning techniques have been used to estimate the vertical position of spherical particles from the defocus pattern, but they require the acquisition of a labelled dataset with finely spaced vertical positions. Here, we describe a simple way to make a dataset of images labelled with vertical position from a single 5 min movie, based on a tilted slide set-up.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
September 2025
Department of Ophthalmology, University of California, Los Angeles, Los Angeles, California, United States.
Purpose: Simulations suggest that displacement of rectus extraocular muscle pulleys in superior oblique (SO) palsy accounts for incomitant strabismus patterns even without postulating SO contractile weakness. We asked how rectus extraocular muscle pulleys reorient during head tilt in SO palsy.
Methods: In 13 subjects with unilateral SO palsy, supine magnetic resonance imaging (MRI) in 2-mm-thick quasi-coronal planes in target-controlled central gaze was repeated in both lateral decubitus positions equivalent to 90° head tilts.
Hua Xi Kou Qiang Yi Xue Za Zhi
August 2025
Dept. of Pediatric Dentistry, Stomatology Hospital, Zhejiang University School of Medicine, School of Stomatology, Zhejiang University, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang Universit
Objectives: This study aimed to investigate the incidence, imaging characteristics, and clinical manifestations of the eruption failure of deciduous molars using panoramic radiographs to provide a foundation for diagnosis and treatment in this population.
Methods: This study retrospectively reviewed panoramic radiographs of children aged 4-8 years obtained from Stomatology Hospital, Zhejiang University School of Medicine between January 2021 and December 2023. A total of 31 331 subjects were included for the radiographic assessment of the tooth eruption failure of deciduous molars.
Dent J (Basel)
August 2025
Stomatology and Maxilo-Facial Surgery Department, Targu Mures Emergency County Hospital, 540136 Târgu Mureș, Romania.
The present study investigated the relation between dental inclination, colorimetric variation, and aesthetic perception according to the modification of incisor inclination. Smile aesthetics, shaped by morphological factors and patient perception, are vital for social attractiveness and treatment success. This study aimed to assess the effect of varying head tilt on the perceived colour of upper central incisors by simulating changes in torque of the tooth, as well as evaluate factors influencing the perception of an aesthetic smile, including morphological characteristics and gingival aesthetic parameters.
View Article and Find Full Text PDF