Background: To evaluate the benefit of an on-line correction protocol based on implanted markers and weekly portal imaging in external beam radiotherapy of prostate cancer. To compare the use of bony anatomy versus implanted markers for calculation of setup-error plus/minus prostate movement. To estimate the error reduction (and the corresponding margin reduction) by reducing the total error to 3 mm once a week, three times per week or every treatment day.

Methods: 23 patients had three to five, 2.5 mm Ø spherical gold markers transrectally inserted into the prostate before radiotherapy. Verification and correction of treatment position by analysis of orthogonal portal images was performed on a weekly basis. We registered with respect to the bony contours (setup error) and to the marker position (prostate motion) and determined the total error. The systematic and random errors are specified. Positioning correction was applied with a threshold of 5 mm displacement.

Results: The systematic error (1 standard deviation [SD]) in left-right (LR), superior-inferior (SI) and anterior-posterior (AP) direction contributes for the setup 1.6 mm, 2.1 mm and 2.4 mm and for prostate motion 1.1 mm, 1.9 mm and 2.3 mm. The random error (1 SD) in LR, SI and AP direction amounts for the setup 2.3 mm, 2.7 mm and 2.7 mm and for motion 1.4 mm, 2.3 mm and 2.7 mm. The resulting total error suggests margins of 7.0 mm (LR), 9.5 mm (SI) and 9.5 mm (AP) between clinical target volume (CTV) and planning target volume (PTV). After correction once a week the margins were lowered to 6.7, 8.2 and 8.7 mm and furthermore down to 4.9, 5.1 and 4.8 mm after correcting every treatment day.

Conclusion: Prostate movement relative to adjacent bony anatomy is significant and contributes substantially to the target position variability. Performing on-line setup correction using implanted radioopaque markers and megavoltage radiography results in reduced treatment margins depending on the online imaging protocol (once a week or more frequently).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2683853PMC
http://dx.doi.org/10.1186/1748-717X-4-13DOI Listing

Publication Analysis

Top Keywords

total error
12
based implanted
8
portal imaging
8
prostate cancer
8
implanted markers
8
bony anatomy
8
prostate movement
8
prostate motion
8
target volume
8
prostate
7

Similar Publications

Purpose: To develop and validate a multimodal deep-learning model for predicting postoperative vault height and selecting implantable collamer lens (ICL) sizes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Ultrasound Biomicroscope (UBM) images combined with clinical features.

Setting: West China Hospital of Sichuan University, China.

Design: Deep-learning study.

View Article and Find Full Text PDF

Quantum low-density parity-check (QLDPC) codes offer a promising path to low-overhead fault-tolerant quantum computation but lack systematic strategies for exploration. In this Letter, we establish a topological framework for studying the bivariate-bicycle codes, a prominent class of QLDPC codes tailored for real-world quantum hardware. Our framework enables the investigation of these codes through universal properties of topological orders.

View Article and Find Full Text PDF

Purpose To assess the effectiveness of an explainable deep learning (DL) model, developed using multiparametric MRI (mpMRI) features, in improving diagnostic accuracy and efficiency of radiologists for classification of focal liver lesions (FLLs). Materials and Methods FLLs ≥ 1 cm in diameter at mpMRI were included in the study. nn-Unet and Liver Imaging Feature Transformer (LIFT) models were developed using retrospective data from one hospital (January 2018-August 2023).

View Article and Find Full Text PDF

A two-axis thrust stand is developed and validated experimentally, enabling direct and simultaneous measurements of two components of the thrust vector of an electric thruster. It is made of two piled-up single-axis stages, each having a hanging deformable parallelogram geometry. A mass deposition calibration method is used to calibrate the thrust stand, including crosstalk between axes.

View Article and Find Full Text PDF

Current treatments for narcolepsy type 1 (NT1) have little impact on psychiatric, cognitive and metabolic comorbidities. Here, we evaluated the feasibility, safety and efficacy of a prospective Exercise Training (ET) program on sleep-related symptoms and comorbidities in NT1. Sedentary adult with NT1 participated in a 6-week supervised ET program followed by a 18-week self-directed program.

View Article and Find Full Text PDF