[A simple and convenient standardization algorithm of NIR spectra].

Guang Pu Xue Yu Guang Pu Fen Xi

National Key Lab of Industrial Control Technology, Zhejiang University, Hangzhou 310027, China.

Published: April 2008


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Due to the limitation of current algorithms for NIR spectral analysis model transfer, a simple and convenient algorithm to standardize the spectra was proposed, and a new performance index called spectra standard error (SSE) was also constructed to evaluate the validity of model transfer algorithms. SSE expresses the ratio of J2 to J1, where J2 describes the distances between the spectra of the same sample using different instruments, and J2 describes the average distance between the spectra of different samples using the original instrument for their central spectrum. In the present paper we first used Savitzky-Golay smoothing to realize baseline correction for different spectra, and then applied standard normal variate method to standardize spectra and polynomial filtering to avoid noise. Besides, we optimized the wavelength range and the window width in Savitzky-Golay smoothing in order to minimize the SSE. After these steps, the standardized spectra can be applied to spectral analysis modeling. By the new algorithm, neither collecting a great number of samples nor need measuring all spectra of training samples using different instruments are needed. For a set of gasoline samples, SSE can be reduced from 1.418 to 0.167 via the new standardization algorithm and satisfactory results were obtained.

Download full-text PDF

Source

Publication Analysis

Top Keywords

simple convenient
8
standardization algorithm
8
spectral analysis
8
model transfer
8
spectra
8
standardize spectra
8
savitzky-golay smoothing
8
spectra applied
8
convenient standardization
4
algorithm
4

Similar Publications

Purpose: To report the level of knowledge, impressions, and satisfaction of Urology readers, authors, and editorial boards regarding Open Access (OA) publishing in the field of Urology and to determine their satisfaction with the current OA models.

Methods: We developed an online, five-section cross-sectional survey including 23 questions. To recruit participants, we used mixed methods to obtain responses based on a simple random sampling and convenience sampling.

View Article and Find Full Text PDF

A Minimally Invasive Method for Generating a Syngeneic Orthotopic Mouse Model of Lung Cancer.

J Vis Exp

August 2025

Department of Neuroscience and Pharmacology, Carver College of Medicine, University of Iowa; Department of Radiation Oncology, Holden Comprehensive Cancer Center, University of Iowa; Geminii, Inc.

Non-small cell lung cancer (NSCLC) continues to be the number one cause of cancer-related death for both women and men worldwide. More information needs to be gathered to understand the interactions between cancer cells, the immune system, the microenvironment within each tumor, and the host tissue to develop more effective treatment modalities. Reported here is a simple, repeatable method for inducing cancer within the mouse lung, allowing for the monitoring of tumor growth from early to late-stage disease.

View Article and Find Full Text PDF

Metal pollution, particularly chromium, in water and food samples is a critical issue due to its transfer to the human body through the food chain and its threat to human health. Among the chromium species that can be found in water samples, chromates are classified as toxic by scientific authorities. Spectroscopic instruments have limitations in metal speciation analysis, and there is a need for suitable methods that allow chromium speciation.

View Article and Find Full Text PDF

DNA base editing is increasingly used for human genetic modification, but methods for monitoring off-target editing are nascent. Here we present a simple model-independent workflow for identifying sites of off-target base-editing in relevant cell types on a genome-wide level. We report that sites of off-target editing by the ABE8e editor could be identified using an ABE8e derivative with restored DSB cleavage activity.

View Article and Find Full Text PDF

Ion Luminescent Micelles: A Surfactant-Mediated Double-End Signal Amplification Strategy for Portable Detection of Phoxim.

Anal Chem

September 2025

State Key Laboratory of Green Chemical Synthesis and Conversion, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310032, PR China.

Residues of organophosphorus pesticides (OPs) raise considerable concern, while achieving high enough detection sensitivity is still a challenge for on-site fluorescence techniques. Herein, we report a "double-end samplification" strategy by encapsulating a low-emission fluorescent ion probe [DCF][P] into a cetyltrimethylammonium bromide (CTAB) hydrophobic core to form ionic luminescent micelles. At the probe end, ionic liquid micelles locally concentrated the probes, achieving a 350-fold fluorescence enhancement.

View Article and Find Full Text PDF