98%
921
2 minutes
20
In this paper we report on the extension of the technique of mapping small angle x-ray scatter (SAXS) across a soft material specimen several millimetres square. In the conventional SAXS mapping technique a pencil beam of x-rays is raster scanned over the specimen with the scatter pattern recorded from each point in the raster. In our technique a wide, parallel beam is used, speeding up the data collection time considerably. An image processing algorithm is used to separate the scatter pattern features from individual points along the line of the beam. To test the efficacy of the technique a phantom was constructed using gelatin and rat tail tendon collagen. Collagen fibres in the phantom were arranged in quarters horizontally, diagonally and vertically leaving one quarter with just gelatin. The phantom was used to collect both raster scanned sets of SAXS patterns spaced at 0.25 mm horizontally and vertically and also a wide beam data set. The width of the beam in this case was approximately 7 mm. Using the third-order diffraction of rat tail tendon intensity data were gathered from each SAXS pattern and used to construct a map. Data from the raster scan image and that from the wide beam are compared. Finally using a phantom made from dehydrated rat tail tendon and paraffin wax a tomographic slice constructed using data from SAXS patterns is shown.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/52/9/006 | DOI Listing |
Anal Chem
September 2025
Department of Chemistry, Southern University of Science and Technology, 518055 Shenzhen, China.
Electrochemiluminescence (ECL) imaging through closed bipolar nanoelectrode arrays (BPnEAs) has emerged as a promising method for in situ label-free wide-field electrochemical imaging. In this study, a cathodic ECL system based on [Ru(bpz)]/SO is combined with the BPnEAs fabricated on silicon nitride membrane windows through focused ion beam nanofabrication, enabling effective bipolar imaging of heterogeneous anodic electrocatalytic reactions. The shape, distribution, size, and material composition of individual electrodes within the array can be precisely controlled.
View Article and Find Full Text PDFCureus
August 2025
Radiation Oncology, Southwest Oncology Centers, Scottsdale, USA.
Neuroendocrine tumors (NETs) originate from neuroendocrine cells, which receive neural input and play a key role in transmitting signals by secreting bioactive substances such as monoamines (e.g., serotonin), peptides (e.
View Article and Find Full Text PDFAnal Methods
September 2025
Vrije Universiteit Amsterdam, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences (AIMMS), Division of BioAnalytical Chemistry, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands.
Polymer-based nanoparticles (PNPs) find wide application in material and pharmaceutical sciences. In order to determine the quality of produced PNPs and understand their function, analytical characterization is essential. Recently, two-dimensional liquid chromatography (2D-LC) has been introduced as an effective means to probe multiple PNP properties, such as size and composition, in an integrated manner.
View Article and Find Full Text PDFNanophotonics
August 2025
National Laboratory of Solid State Microstructures, Key Laboratory of Intelligent Optical Sensing and Manipulation, Jiangsu Key Laboratory of Artificial Functional Materials, College of Engineering and Applied Sciences, C ollaborative Innovation Center of Advanced Microstructures, Nanjing University
Frequency modulated continuous wave (FMCW) light detection and ranging (LiDAR) has recently become a research hotspot in the fields of autonomous driving and intelligent perception due to its high-precision ranging and velocity measurement capabilities. However, the existing LiDAR systems are usually challenged in expanding the field-of-view (FOV), which often comes at the expense of beam quality and degrades the detection accuracy and signal-to-noise ratio. On the other hand, the complexity of data processing algorithms may introduce significant measurement inaccuracies, potentially leading to substantial deviations in the final results.
View Article and Find Full Text PDFJ Oral Biol Craniofac Res
August 2025
Prosthetic Dentistry, Department of Prosthetic Dentistry, Faculty of Dental Sciences, University of Peradeniya, Sri Lanka.
Introduction: Root fusion is considered to present when there is no evidence of periodontal space or presence of bone between the different roots of the molar at any apical level to the bifurcation area. Fused roots in maxillary molars pose important clinical implications, mainly in the field of endodontics. Based on the wide variations in previous studies done in different populations and the clinical implications, the present study is aimed to assess root and root canal morphology in maxillary first and second molars with fused roots in a Sri Lankan population.
View Article and Find Full Text PDF