Article Abstract

Modelflow, when applied to non-invasive fingertip pulse pressure recordings, is a poor predictor of cardiac output (Q, litre x min(-1)). The use of constants established from the aortic elastic characteristics, which differ from those of finger arteries, may introduce signal distortions, leading to errors in computing Q. We therefore hypothesized that peripheral recording of pulse pressure profiles undermines the measurement of Q with Modelflow, so we compared Modelflow beat-by-beat Q values obtained simultaneously non-invasively from the finger and invasively from the radial artery at rest and during exercise. Seven subjects (age, 24.0 +/- 2.9 years; weight, 81.2 +/- 12.6 kg) rested, then exercised at 50 and 100 W, carrying a catheter with a pressure head in the left radial artery and the photoplethysmographic cuff of a finger pressure device on the third and fourth fingers of the contralateral hand. Pulse pressure from both devices was recorded simultaneously and stored on a PC for subsequent Q computation. The mean values of systolic, diastolic and mean arterial pressure at rest and exercise steady state were significantly ( P < 0.05) lower from the finger than the intra-arterial catheter. The corresponding mean steady-state Q obtained from the finger (Qporta) was significantly ( P < 0.05) higher than that computed from the intra-arterial recordings (Qpia). The line relating beat-by-beat Qporta and Qpia was y =1.55 x -3.02 ( r2 = 0.640). The bias was 1.44 litre x min(-1) and the precision was 2.84 litre x min(-1). The slope of this line was significantly higher than 1, implying a systematic overestimate of Q by Qporta with respect to Qpia. Consistent with the tested hypothesis, these results demonstrate that pulse pressure profiles from the finger provide inaccurate absolute Q values with respect to the radial artery, and therefore cannot be used without correction with a calibration factor calculated previously by measuring Q with an independent method.

Download full-text PDF

Source
http://dx.doi.org/10.1042/CS20030303DOI Listing

Publication Analysis

Top Keywords

pulse pressure
20
pressure profiles
12
litre min-1
12
radial artery
12
cardiac output
8
fingertip pulse
8
pressure
8
rest exercise
8
finger
6
pulse
5

Similar Publications

Optimized FDA Blood Pump: A Case Study in System-Level Customized Ventricular Assist Device Designs.

Ann Biomed Eng

September 2025

Department of Mechanical Engineering, Koc University, Rumeli Feneri Campus, Sarıyer, 34450, Istanbul, Turkey.

Purpose: The design and development of ventricular assist devices have heavily relied on computational tools, particularly computational fluid dynamics (CFD), since the early 2000s. However, traditional CFD-based optimization requires costly trial-and-error approaches involving multiple design cycles. This study aims to propose a more efficient VAD design and optimization framework that overcomes these limitations.

View Article and Find Full Text PDF

Objective: To quantify agreement between oscillometric non-invasive blood pressure (NIBP) and invasive arterial blood pressure (IBP) in infants <500 g during the first postnatal week.

Study Design: Retrospective cohort of infants with a birth weight <500 g admitted to a tertiary NICU (2011-2023). Paired IBP-NIBP readings obtained within 1 min were analyzed.

View Article and Find Full Text PDF

The effects of positive end-expiratory pressure and end-inspiratory pause on dead space and alveolar ventilation in mechanically ventilated dogs.

Vet Anaesth Analg

August 2025

Department of Anesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires, Argentina.

Objective: To evaluate the effect of 5 cmHO positive end-expiratory pressure (PEEP) and end-inspiratory pause (EIP) on airway dead space (V) and its resultant effects on alveolar tidal volume (V) and physiological dead space-to-tidal volume ratio (V/V) in dorsally recumbent anesthetized dogs.

Study Design: Prospective, controlled clinical study.

Animals: Healthy adult dogs (n = 20, > 20 kg) undergoing elective surgery.

View Article and Find Full Text PDF

Total laryngectomy (TLE) results in the permanent separation of the respiratory and digestive tracts, requiring all airway interventions to occur exclusively via a neck stoma. Although airway obstruction in post-laryngectomy patients is uncommon, it can rapidly become fatal without prompt recognition and understanding of the altered anatomy. Here, we report the case of a patient with a recent TLE for squamous cell carcinoma, who presented to a rural Emergency Department (ED) in acute respiratory distress.

View Article and Find Full Text PDF