Disaster Med Public Health Prep
April 2025
Objective: To describe the protocol and progress of a thyroid study using thyroid ultrasonography in emergency workers who responded to the Fukushima nuclear accident.
Methods: Thyroid ultrasonography was performed on Fukushima emergency workers at over 60 health examination institutions. The accuracy of ultrasonography is controlled by standard procedural protocols, examiner training, and a central review system.
Radiat Prot Dosimetry
August 2023
It is very important to evaluate the diameters (activity median aerodynamic diameter) of plutonium dioxide (PuO2) particles for internal exposure dose evaluation. In this study, a method of evaluating PuO2 particle diameters using an alpha-particle imaging detector was developed. PuO2 particles with different diameters were modeled by Monte Carlo simulation, and the change in the shape of the energy spectrum for each particle diameter was evaluated.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2018
This article introduces the first accident of internal contamination with plutonium (Pu) or americium (Am) in Japan for which treatment was carried out. An accident of internal contamination with Pu and Am occurred at a Pu research facility at Oarai-town of Ibaraki prefecture in Japan. A plastic bag containing these radionuclides ruptured when five workers were inspecting a storage container in a hood.
View Article and Find Full Text PDFPlutonium dioxide (PuO2) is used to fabricate a mixed oxide fuel for fast breeder reactors. When a glove box containing PuO2 fails, such as by rupture of a glove or a vinyl bag, airborne contamination of plutonium (Pu) can occur. If a worker inhales PuO2 particles, they will be continually irradiating their lung tissue with alpha particles, and this could cause lung cancer.
View Article and Find Full Text PDFThe Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident in 2011 resulted in a release of radionuclides into the environment (I: 142.9 PBq, Cs:12.4 PBq).
View Article and Find Full Text PDFJ Radiat Res
August 2016
Enormous quantities of radionuclides were released into the environment following the disastrous accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March 2011. It is of great importance to determine the exposure doses received by the populations living in the radiologically affected areas; however, there has been significant difficulty in estimating the internal thyroid dose received through the intake of short-lived radionuclides (mainly, (131)I), because of the lack of early measurements on people. An estimation by the National Institute of Radiological Sciences for 1 April 2012 to 31 March 2013 was thus performed using a combination of the following three sources: thyroid measurement data ((131)I) for 1080 children examined in the screening campaign, whole-body counter measurement data ((134)Cs, (137)Cs) for 3000 adults, and atmospheric transport dispersion model simulations.
View Article and Find Full Text PDFRadiat Prot Dosimetry
September 2016
In direct organ measurements, there can be uncertainty to the quantified amount of activity due to variations in detector locations. Here, the authors demonstrate a new use of an imaging plate (IP) for evaluating this uncertainty. The method requires only that an array of regions of interest (ROIs) is set on a latent image obtained from the IP; each ROI conforms to an active area of the detector to be used.
View Article and Find Full Text PDFThe authors describe the results of direct measurements made on three persons who stayed in Tokai-mura, a village located ∼110 km south of the Fukushima Daiichi Nuclear Power Station (FDNPS), during the arrival of significant radioactive plumes released from the FDNPS as a consequence of the Tohoku earthquake/tsunami/FDNPS accident in March 2011. These measurements were made using a NaI(Tl) spectrometer and a whole-body counter shortly after the accident. Their thyroid equivalent doses ((131)I) were estimated to be 0.
View Article and Find Full Text PDFEnviron Int
November 2013
Namie Town was heavily contaminated by the Fukushima Daiichi Nuclear Power Station accident. The thyroid equivalent dose for residents who lived in Namie was estimated using results of whole body counting examinations which were carried out by the Japan Atomic Energy Agency a few months after the nuclear accident. Photon peaks of (131)I and (134)Cs were previously measured by the authors using a NaI(Tl) scintillation spectrometer and that information was used to estimate the (131)I/(134)Cs activity ratio of total intake in the present study.
View Article and Find Full Text PDFThe radionuclide pair (214)Bi and (214)Po which belongs to the uranium series interferes with airborne radionuclide measurement needed for the radiation management of a nuclear facility. Time intervals between (214)Bi (β) and (214)Po (α) are much shorter than artificial radionuclides due to the short half-life of (214)Po (164 μs). The purpose of this study is to develop of a new analytical method (time interval analysis: TIA) based on the beta-alpha coincidence method for selective measurement of (214)Bi-(214)Po.
View Article and Find Full Text PDFRadiation protection methodologies concerning individual monitoring, workplace monitoring and environmental monitoring in nuclear fuel facilities have been developed and applied to facilities in the Nuclear Fuel Cycle Engineering Laboratories (NCL) of Japan Atomic Energy Agency (JAEA) for over 40 y. External exposure to photon, beta ray and neutron and internal exposure to alpha emitter are important issues for radiation protection at these facilities. Monitoring of airborne and surface contamination by alpha and beta/photon emitters at workplace is also essential to avoid internal exposure.
View Article and Find Full Text PDFA transition edge sensor (TES) microcalorimeter has been developed for use as an energy dispersive X-ray spectrometer. The TES microcalorimeter is a thermal detector that enables one to determine the energy of an incident photon by measuring the resultant increase in temperature. In this work, a Ti/Au TES microcalorimeter was developed to measure LX rays emitted by transuranium elements.
View Article and Find Full Text PDFAn in vivo measurement system using an imaging plate (IP) system was developed, which displayed images reflecting (239)Pu distribution in the lung of a phantom. The detection limits of the IP system for 1-12h exposures were between 1670 and 245 Bq at a 1.6 cm chest wall thickness.
View Article and Find Full Text PDFA new 241Am lung monitoring system without shielding was devised by using an imaging plate system. The Lawrence Livermore National Laboratory's realistic torso phantom containing a 241Am lung was covered by imaging plates sealed in lightproof bags. The imaging plate system displayed 241Am lung images characteristic of the lung shape of the torso phantom.
View Article and Find Full Text PDF