Publications by authors named "Roberto Sorrentino"

Background: Graphene oxide (GO) is widely explored as a functional additive in polymer composites; however, its simple physical dispersion in dental resins often leads to poor interfacial stability and limited long-term performance. Covalent functionalization may overcome these limitations by enabling chemical integration into the polymer matrix. This study presents the synthesis and FT-IR/Raman characterization of GRAPHYMERE, a novel graphene oxide-based monomer obtained through exfoliation, amine functionalization with 1,6-hexanediamine, and transamidation with methyl methacrylate.

View Article and Find Full Text PDF

Objectives: To evaluate the effect of maxillary midline deviation and crown width disproportion on the perception of smile attractiveness through full-face images among dentists and laypeople.

Methods And Materials: A full portrait image of a smiling 25-year-old female, exhibiting good dental alignment, midline position, and tooth size symmetry, was selected as a model for the present study. The original image was digitally modified using photo editing software (Photoshop CC, Version 25.

View Article and Find Full Text PDF

A method is described for the cost-effective tracking of mandibular movements using an open-source software program (Blender v. 4.3; Blender Foundation) in combination with video recordings and intraoral scans.

View Article and Find Full Text PDF

Objectives: This study evaluated the accuracy of the Medit i700 intraoral scanner (IOS) in capturing horizontal tooth preparations at different depths below the gingival margin and assessed its ability to detect surfaces beyond the finish line.

Methods: Using CAD software, two abutments of a standard maxillary first molar were designed with horizontal preparation and 0.8 mm chamfer at 1 mm and 2 mm depths below the gingival margin.

View Article and Find Full Text PDF

Aim: This systematic review investigates the effectiveness of implant therapy in patients with and without a history of periodontitis in terms of implant loss, peri-implant marginal bone loss (MBL), and occurrence of peri-implant diseases.

Methods: The protocol of the present meta-analysis was registered on PROSPERO (CRD42021264980). An electronic search was conducted up to April 2024.

View Article and Find Full Text PDF
Article Synopsis
  • This study explored how different shapes of the roof of the mouth (palates) affect the accuracy of a dental scanning device (TRIOS 4) for patients without teeth (edentulous maxillae).
  • Six types of artificial teeth molds were created, representing various palatal morphologies, and multiple scans were taken to measure their accuracy (trueness) and consistency (precision) using specific software.
  • Results showed that medium palates yielded the highest accuracy, and while all tested palates were within acceptable accuracy limits, adding rugae (palatal wrinkles) improved the precision for deeper palates and the accuracy for flat ones.
View Article and Find Full Text PDF

This retrospective study evaluated the clinical outcomes of lithium disilicate prostheses on teeth and implants. A total of 860 restorations, including crowns, veneers, and onlays, were delivered to 312 patients. Patients with uncontrolled gingival inflammation and/or periodontitis were excluded, while patients with occlusal parafunctions were included.

View Article and Find Full Text PDF

Purpose: To evaluate clinical performances of two lithium disilicate systems (Initial LiSi press vs Initial LiSi Block, GC Co.) using modified United States Public Health Service (USPHS) evaluation criteria and survival rates after 4 years of clinical service.

Methods: Partial adhesive crowns on natural abutment posterior teeth were made on 60 subjects who were randomly divided into two groups: Group 1: Initial LiSi press and Group 2: Initial LiSi Block.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the accuracy of an intraoral scanner (IOS - Medit i700) on tooth abutments with vertical preparations at 2 depths below the free gingival margin, and to determine if the IOS can reproduce the area beyond the finish surface of the tested preparation geometry.

Methods: Two abutments for a maxillary first molar were designed by means of CAD software, with vertical preparations set at 1 and 2 mm below the gingiva. These abutments were subsequently printed in resin and placed on a reference model.

View Article and Find Full Text PDF

Statement Of Problem: Manufacturers of several intraoral scanners have recommended a 2-step strategy for scanning the edentulous mandible. The 2-step technique requires scanning one side first and then moving to the other side. However, whether inconsistency in stitching occurs that results in loss of accuracy or distortion is unclear.

View Article and Find Full Text PDF

Objectives: To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth?

Data: Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered.

Sources: Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool.

View Article and Find Full Text PDF

The new perspective of using waste biomass to cultivate mushrooms as a source of protein for human nutrition, in line with the circular economy principles, is receiving increasing attention in the scientific community and represents great wealth in terms of environmental sustainability. is a mushroom also known as cardunculus mushroom due to its ability to grow on this plant. This study explores the potential intrinsic properties of cardunculus (for example, the presence of inulin in the roots) as raw material for the growth of cardunculus mushrooms, and the influence on heteroglycan content and nutrition parameters of the fruiting bodies.

View Article and Find Full Text PDF

We synthetized a new rod-coil block copolymer (BCP) based on the semiconducting polymerpoly({4,8-bis[(2-ethylhexyl)oxy]benzo[1,2-:4,5-]dithiophene-2,6-diyl}{3-fluoro-2-[(2-ethylhexyl)carbonyl]thieno[3,4-]thiophenediyl}) (PTB7) and poly-4-vinylpyridine (P4VP), tailored to produce water-processable nanoparticles (WPNPs) in blend with phenyl-C71-butyric acid methyl ester (PCBM). The copolymer PTB7--P4VP was completely characterized by means of two-dimensional nuclear magnetic resonance (2D-NMR), matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry (MS), size-exclusion chromatography (SEC), and differential scanning calorimetry (DSC) to confirm the molecular structure. The WPNPs were prepared through an adapted miniemulsion approach without any surfactants.

View Article and Find Full Text PDF

Background: To assess the quantity of dentin exposure detected by 3 operators with different clinical expertise for 2 designs of tooth preparation for laminate veneers: window (WI) and butt joint (BJ). Methods: 20 intact maxillary central incisors were collected and then prepared for laminate veneers to a depth of 0.6 mm, with a cervical mini-chamfer finish line of 0.

View Article and Find Full Text PDF

Background: Pediatric dentists could play a key role in the prevention of human papilloma virus (HPV)-related oropharyngeal cancer (OP-cancer). The aim of this study was to assess knowledge, perception, and attitude on HPV-related OP-cancer, HPV infection, and HPV vaccination among Italian pediatric dentists.

Methods: A cross-sectional study was conducted.

View Article and Find Full Text PDF

The emergence profile is a crucial factor in facilitating favorable esthetic outcomes and maintaining peri-implant health and stability. It should be evaluated not simply in terms of morphology but as a clinical variable closely related to material properties and clinical approaches; in this way, this critical factor-which can significantly influence the integration, stability, and preservation of bone and soft tissues-can be comprehensively planned. Soft tissue integration and adherence to prosthetic components are paramount elements in the preservation and protection of bone from contamination and infection.

View Article and Find Full Text PDF

Colloidal semiconductor nanoplatelets (NPLs) are a subgroup of quantum confined materials that have recently emerged as promising active materials for solution processed light-emitting diodes (LEDs) thanks to their peculiar structural and electronic properties as well as their reduced dimensionality. Nowadays, the conventional structure for NPL-based LEDs makes use of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) as a hole transporting layer (HTL). This is a well-known conjugated conductive polymer because it leads to high LED efficiency, though it has limited stability in air due to its intrinsic acidity and hygroscopicity.

View Article and Find Full Text PDF

Objectives: The present narrative review was focused on the optical properties, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate ceramics (ZLS) for Computer-aided design / Computer-aided manufacturing (CAD/CAM) technologies.

Data/sources: A literature search was performed by 3 calibrated independent researchers on PubMed, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The criteria for inclusion were: 1) papers addressing at least one of the following variables about ZLS: optical properties, surface treatment, adhesion, and clinical indications; 2) in vitro, in silico, or in vivo studies; 3) case reports; 4) systematic reviews.

View Article and Find Full Text PDF
Article Synopsis
  • - OSCC (Oral Squamous Cell Carcinoma) is a significant global health issue, with many healthcare providers (HCPs) lacking awareness and knowledge about the condition, leading to poor early detection.
  • - A systematic review assessed the knowledge, attitudes, and practices (KAP) of HCPs towards OSCC, revealing significant differences in understanding between dentists and medical practitioners, particularly regarding risk factors like alcohol use.
  • - The review indicates a low rate of OSCC screenings and highlights the necessity for improved training for healthcare providers, both before and after graduation, to enhance their competency in recognizing and addressing this serious health concern.
View Article and Find Full Text PDF

Objectives: This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems.

Data/sources: An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers.

View Article and Find Full Text PDF

Conjugated polymers with ionic pendant groups (CPEs) are receiving increasing attention as solution-processed interfacial materials for organic solar cells (OSCs). Various anionic CPEs have been successfully used, on top of ITO (Indium Tin Oxide) electrodes, as solution-processed anode interlayers (AILs) for conventional devices with direct geometry. However, the development of CPE AILs for OSC devices with inverted geometry is an important topic that still needs to be addressed.

View Article and Find Full Text PDF

Purpose: This randomized controlled clinical trial evaluated the behavior of lithium disilicate partial crowns by means of a novel Functional Index for Teeth (FIT).

Methods: 105 subjects in need of at least a single prosthetic restoration in posterior areas were treated with adhesive partial crowns (for a total of 170 restorations) onto natural vital abutment teeth and followed-up annually for 4 years. Subjects were randomly divided into two experimental groups: Group 1, e.

View Article and Find Full Text PDF
Article Synopsis
  • * Two types of typodonts (wrinkled and smooth) were scanned using an industrial metrological machine to create digital reference scans, which were then compared to results from the three scanning techniques: buccopalatal, S-shaped, and palatobuccal.
  • * Results showed varying accuracy levels for the techniques, with the buccopalatal method yielding the highest trueness values, indicating that technique choice significantly impacts scanning accuracy for edentulous maxillas.
View Article and Find Full Text PDF
Article Synopsis
  • * An in vitro experiment compared the accuracy (trueness and precision) of scans from a typodont using an intraoral scanner with scans obtained from laboratory scanners using stone casts and polysulfide impressions.
  • * Results indicated that the intraoral scanner provided significantly higher accuracy compared to the other methods, with trueness values notably lower for the intraoral scans, demonstrating its potential benefits in dental practices.
View Article and Find Full Text PDF