Publications by authors named "Vesna Miletic"

The calcium silicate-based sealers currently available on the market have different compositions and formulations, which is why their physical and chemical properties may vary. (1) The aim of the study was to measure the physico-chemical properties of calcium silicate-based sealers and their push-out bond strength to root dentine, comparing two push-out testing protocols. (2) Standardized specimens of EndoSequence BC, BioRoot RCS, MTA Fillapex, and AH Plus (control) were subjected to pH measurements over 28 days.

View Article and Find Full Text PDF

This study evaluated the colour and translucency changes in resin cements and lithium disilicate veneer restorations, as well as the sorption and solubility of cements after staining. Four resin cements (G-CEM ONE, RelyX Universal, Panavia V5, Variolink Esthetic) were tested. Cylindrical specimens and LiSi veneer restorations cemented to a G-aenial Universal Injectable dentine base (N = 10/group) were stained in black tea for 72 h.

View Article and Find Full Text PDF
Article Synopsis
  • Traditional tooth preparation can be uncomfortable and risky, but femtosecond lasers provide a precise, non-invasive alternative that minimizes these issues.
  • This study aimed to evaluate how femtosecond laser treatment affects enamel and dentin through a review of in vitro and in vivo studies, following strict guidelines for systematic reviews.
  • After a thorough literature search, 48 relevant studies were identified, focusing on the quality of tooth preparation and the effects of laser parameters, although the overall quality of these studies was not assessed.
View Article and Find Full Text PDF

Minimally invasive access cavities have been proposed in the last decade to reduce tooth tissue loss during endodontic treatment and mitigate compromised fracture resistance of endodontically treated teeth. Fracture resistance of molars with different types of access cavity design may be affected by restorative materials and aging. Insufficient literature data exist on the effect of cavity design and type of restorative materials on restorative aspects such as material adaptation or photo-polymerization in restricted access cavities.

View Article and Find Full Text PDF
Article Synopsis
  • - The study compared new calcium phosphate-based cements, specifically a modified version with acetylsalicylic acid (CPCA), with a known cement, mineral trioxide aggregate (MTA), focusing on their biological properties and effectiveness.
  • - Cements were synthesized using strontium, copper, and zinc-doped hydroxyapatite, and were tested for compressive strength, setting time, bioactivity, and biocompatibility using human dental pulp stem cells and zebrafish models.
  • - Results indicated that CPCA was more biocompatible and had an improved safety profile compared to MTA and regular calcium phosphate cement, without showing toxicity, while also exhibiting effective antibiofilm properties.
View Article and Find Full Text PDF

Objectives: To evaluate the effects of enhanced personal protective equipment (Enhanced_PPE) on student-operator's experience and restorative procedure.

Methods: Student-operators (N = 29 Year 3 dental students) performed Class II composite restorations (SimpliShade, Kerr) in typodont upper molars (OneDental) equipped with N95 respirators, full-face shields, disposable headwear and gowns (Enhanced_PPE) or surgical masks, protective glasses/goggles and non-disposable gowns (Standard_PPE) 2 weeks later. Cavity dimensions were measured on cone beam computed tomography images.

View Article and Find Full Text PDF
Article Synopsis
  • This study analyzes the dentin abrasivity of various whitening toothpastes using a specific measuring method (RDA-PE), focusing on those that contain acids.
  • A total of 100 bovine dentin specimens were tested with different whitening toothpastes, including those with hydrogen peroxide and silica, undergoing extensive brushing to measure abrasion levels.
  • Results showed that hydrogen peroxide toothpastes had lower abrasivity compared to silica toothpastes, and particle content in the toothpaste significantly influenced the overall abrasivity values.
View Article and Find Full Text PDF

Objective: To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite.

Materials And Methods: For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy.

View Article and Find Full Text PDF

Objectives: To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth?

Data: Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered.

Sources: Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool.

View Article and Find Full Text PDF

This study aimed to (1) comparatively analyze properties of Sr- and Mg-substituted hydroxyapatite (HAP)-based dental inserts; (2) evaluate insert bonding to restorative materials, and (3) evaluate the effect of doped HAP inserts on fracture resistance (FR) of human molars with large occlusal restorations. By ion-doping with Sr or Mg, 3 insert types were obtained and characterized using XRD, SEM, Vickers hardness and fracture toughness. Shear bond strength (SBS) was determined between acid etched or unetched inserts and following materials: Maxcem cement (Kerr); Filtek Z250 (3M) bonded with Single Bond Universal (SBU; 3M) or Clearfil Universal (Cf; Kuraray).

View Article and Find Full Text PDF

High elution and diffusion of 2-hydroxylethyl methacrylate (HEMA) and camphorquinone (CQ) through dentinal tubules may induce pulp injury and postoperative sensitivity. We aimed to investigate the melatonin protective effect in HEMA- and CQ-treated human dental pulp cells (hDPCs) as well as its relevance in a mechanism for postoperative sensitivity in diabetic patients. hDPCs were exposed to HEMA (5 mM) and/or CQ (1 mM) in the absence and presence of melatonin (MEL) (0.

View Article and Find Full Text PDF

Article Title And Bibliographic Information: Bonding of Glass-Ionomer Cement and Adhesives to Silver Diamine Fluoride-treated Dentin: An Updated Systematic Review and Meta-Analysis. Fröhlich TT, Botton G, Rocha RO. J Adhes Dent.

View Article and Find Full Text PDF

Objectives: To evaluate CIEDE2000/CIELAB differences in color (ΔE/ΔE), and translucency parameter (ΔTP/ΔTP), and gloss of gingiva-colored resin-based restorative materials upon staining/aging.

Materials And Methods: Disc-shaped, 10 mm in diameter, and 2-mm-thick samples (n = 5/group) were made from giomer (Beautifil II gingiva), oligomer-based (crea.lign GUM gel), CAD/CAM polymethyl-methacrylate-based (IvoBase CAD), PMMA-based (ProBase Hot), and dimethacrylate-based (SR Nexco Paste Gingiva).

View Article and Find Full Text PDF

This study investigated differences in colour (ΔE) and translucency parameter (ΔTP) of nanofilled/microhybrid composites and a glass-ionomer cement following immersion in bioflavonoid (Citrox)- or chlorhexidine-based mouth rinses. Sixty disc-shaped specimens (N = 5/group) of Filtek Supreme (3M), Gradia Anterior (GC) and Fuji IX (GC) were exposed to Citrox/0.2%CHX (Perio+0.

View Article and Find Full Text PDF

Objectives: This retrospective study evaluated the factors influencing the clinical failure of noncarious cervical lesion (NCCL) restorations.

Methods: Patients were routinely treated by undergraduate or postgraduate students and randomly received a clinical recall evaluation. A retrospective study was performed with two experienced calibrated examiners to evaluate NCCL restorations, including the critical parameters of retention, caries, marginal discoloration, and marginal integrity.

View Article and Find Full Text PDF

Background: The outbreak of COVID-19 pandemic in 2020 has dramatically changed teaching approach in dental schools due to the switch to distance learning and the lack of practice training in direct contact with patients with possible impact on clinical skills of students. The aim of the study was to assess the level of the 2020 final year dental students' self-confidence in performing different dental procedures through specially designed questionnaire and compare it to self-confidence of the 2019 final year students.

Materials And Methods: An anonymous questionnaire consisting of 40 questions regarding self-confidence level in performing 40 different dental procedures and based on five points Likert-like scale was distributed during November 2020 to final year dental students whose studies were disrupted by the COVID-19 pandemic lockdown in one semester.

View Article and Find Full Text PDF

The objective of this work was to measure and correlate the degree of conversion (DC), mechanical properties and monomer elution from self-, dual- and light-cured core composites. Five samples of each of the following materials were prepared for each test: Clearfil (Core, Photo Core, Automix), Bisco (Core-Flo, Light-Core and Bis-Core). DC was determined using FTIR, compressive and flexural strength and modulus of elasticity using a universal testing machine and microhardness using Vickers hardness.

View Article and Find Full Text PDF

Objectives: This systematic review and meta-analysis evaluated the effects of non-thermal atmospheric plasma (NTAP) treatment on dentin wetting and adhesive-dentin bond strength.

Data/sources: This report followed the PRISMA 2020 statement. Two reviewers conducted literature search of MEDLINE, Web of Science and Scopus databases up to the end of November 2020.

View Article and Find Full Text PDF

The aim of this study was to compare color changes, surface roughness and gloss of a microhybrid and nanohybrid composite whitened in a simulated in-office or at-home procedure using 40% hydrogen peroxide or 16% carbamide peroxide, respectively. CIELab coordinates were measured before, during and after treatment using VITA EasyShade V (VITA) and ∆E calculated. Surface roughness was measured using a surface roughness tester (SJ210; Mitutoyo).

View Article and Find Full Text PDF

Objective: To analyze the effects of factors 'composite,' 'medium,' and 'time' on color, translucency, and sorption/solubility of sculptable universal composites for enamel layering upon immersion in colored beverages.

Materials And Methods: Disk-shaped specimens, 10 mm in diameter and 2 mm thick (n = 5/group), of ultrafine, hybrid composite Essentia (GC), microhybrid Gaenial Anterior (GC), nanofilled Filtek Ultimate Enamel and Body ( 3M ESPE) were immersed in red wine, coffee, or distilled water for 15 days. CIELab color coordinates were measured and CIEDE2000 (∆E ) and Translucency Parameter differences (∆TP ) were calculated.

View Article and Find Full Text PDF

Introduction: Open pores between endodontic sealer and root canal walls present potential niches for bacterial growth and migration pathways. The aim was to assess the internal and external porosity of calcium silicate-based sealers and to ascertain the long-term effect of storage in simulated body fluid on sealer porosity.

Methods: Sixteen single-rooted teeth were filled with gutta-percha and 1 of 4 root canal sealers: BioRoot RCS, EndoSequence BC, MTA Fillapex, or AH Plus.

View Article and Find Full Text PDF

The application of sintered calcium phosphate dental inserts in the central part of tooth cavities can reduce amount of embedded dental composite and polymerization shrinkage of final dental fillings. The aim of this study was to analyze comparatively physico-chemical and mechanical properties of dental inserts and shear bond strength (SBS) between three dissimilar hydroxyapatite-based dental inserts and different restorative materials, after application of different clinical protocols. Starting from two different hydroxyapatite nano powders and nanostructured stabilized zirconia (YSZ), monophasic two-step sintered dense HAp inserts (TSSHAp), biphasic single-step sintered controlled porous inserts (HAp/TCp), and single-step sintered reinforced HAp/YSZ inserts were processed and characterized.

View Article and Find Full Text PDF

Objective: To determine color changes in bulk-fill composite and universal composite restorations with dissimilar dentin replacement materials in extracted teeth after staining in red wine.

Materials And Methods: Cylindrical, 4 mm deep, class I cavities were prepared in 140 human molars. Bottom 2 mm was restored with Biodentine (Septodont), everX posterior (GC) or experimental HAP inserts.

View Article and Find Full Text PDF

Objectives: The study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives.

Materials And Methods: Mid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O, He + 1.5% O), power input (1 or 3 W), and tip-to-surface distance (2, 4, or 8 mm).

View Article and Find Full Text PDF

Objectives: To evaluate optical properties (color and translucency) of 'sandwich' restorations of resin-based composites and esthetically unfavorable dentin restoratives.

Methods: Cylindrical 'dentin' specimens (8mm in diameter and 2mm thick, N=5/group) were prepared using EverX Posterior (GC), Biodentine (Septodont), experimental hydroxyapatite (HAP) or conventional composites (Gradia Direct Posterior, GC; Filtek Z250 and Filtek Z500, 3M ESPE). Capping 'enamel' layers were prepared using composites (Gradia Direct Posterior, Filtek Z250 or Z550) of A1 or A3 shade and the following thickness: 0.

View Article and Find Full Text PDF