Article Abstract

Statement Of Problem: Manufacturers of several intraoral scanners have recommended a 2-step strategy for scanning the edentulous mandible. The 2-step technique requires scanning one side first and then moving to the other side. However, whether inconsistency in stitching occurs that results in loss of accuracy or distortion is unclear.

Purpose: The purpose of this clinical study was to measure the potential distortion of intraoral scans of edentulous mandibular arches made with a 2-step scanning strategy and to assess their differences with conventional impressions.

Material And Methods: Twenty mandibular edentulous arches were scanned by 1 investigator with an intraoral scanner using a 2-step scanning strategy, and a corresponding polysulfide conventional impression was obtained. The conventional impression was then immediately scanned with the same intraoral scanner. The obtained standard tessellation language (STL) files were superimposed with a surface-matching software program. After a preliminary alignment, the STL meshes were trimmed and reoriented; then, the final alignment was carried out and meshes moved to a metrology software program where their mean distance was measured. In addition, a surface curve (SIOS) was traced on the intraoral scan from the right to left retromolar pad along the residual ridge and automatically projected onto to the conventional impression scan to obtain a new curve (SC). The mean distance between SIOS and SC was measured and recorded as an indicator of the distortion by considering the X-, Y-, and Z-axes and the overall 3-dimensional (3D) deviation. The analysis was performed for the full curve length and after dividing it into 6 regions of interest. Univariate and multivariate statistical analyses were used to investigate the significance of the extent of the mean 3D distance, as well as the effects of measurement positions (side and region) between and within patients on differences along the X-, Y-, and Z-axes (α=.05).

Results: The mean (-0.08 mm; standard error: 0.025) 3D distance between the intraoral scan and conventional impression was significantly different from zero (P=.003). No significant effect of the factor "side" was found by using generalized estimated equation models for the X-, Y-, and Z-axes, and global 3D deviations between SIOS and SC (P>.05), which appeared to exclude distortion. Conversely, a significant effect was found for the factor "region" (P<.05), with no significant differences (P>.05) between corresponding regions on the 2 sides.

Conclusions: Intraoral scans of the edentulous mandibular arch made in a 2-step procedure did not exhibit significant distortion in comparison with conventional impressions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2023.09.029DOI Listing

Publication Analysis

Top Keywords

conventional impression
16
intraoral scans
12
scans edentulous
12
edentulous mandibular
12
2-step scanning
12
scanning strategy
12
intraoral
8
distortion intraoral
8
mandibular arch
8
arch 2-step
8

Similar Publications

Background: In the clinical practice of Korean Medicine, pharmacopuncture therapy and acupotomy (PA) are being increasingly explored as potential treatment options for degenerative lumbar spinal stenosis (LSS). In this study, we aimed to evaluate the effectiveness and safety of combining PA with conventional Korean Medicine treatment (CKMT) in patients with degenerative LSS.

Methods: A pragmatic, assessor-blinded, randomized controlled trial was conducted with 104 participants aged 40-75 years diagnosed with degenerative LSS.

View Article and Find Full Text PDF

Background: Neuroimmune processes are often implicated in young people with atypical neuropsychiatric disorders, yet treatment implications remain controversial. This case series details young people with primary psychiatric disorders who received adjunctive immunotherapy after thorough investigation and extensive conventional treatments.

Methods: We evaluated 45 individuals (93% female, ages 12-30 years) with atypical psychiatric presentations suggesting potential neuroimmune involvement.

View Article and Find Full Text PDF

Purpose: Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method.

Materials And Methods: Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the effect of clinically practical auxiliary geometric devices (AGD) on measurement trueness and scan time in full-arch implant-supported prostheses, focusing on different intraoral scanners (IOS) and implant angulations.

Materials And Methods: Four implants were planned in an edentulous maxillary arch and divided into two groups based on posterior implant angulation: Model A (Parallel) and Model B (30°). Each model was evaluated under three auxiliary geometric devices (AGD) application types (std, agd1, agd2), and scanned using three different intraoral scanners (IOSs) [3Shape Trios 3 (T), Medit i700 (M), and Cerec Primescan (PS)], resulting in nine groups per model (n = 10).

View Article and Find Full Text PDF

Background Accurate impressions are essential for the long-term success of implant-supported restorations. Both conventional and digital techniques are routinely used in clinical implantology, each with its own advantages and limitations. This study aimed to evaluate and compare the precision of digital and conventional implant impressions and compare the marginal fit of crowns obtained from digital impressions and those obtained from conventional impressions.

View Article and Find Full Text PDF