ACS Appl Mater Interfaces
July 2025
A p-type oxide semiconductor can advance oxide electronics by enabling bipolar applications, such as p-n junctions and complementary logic devices. As a single-cation species, p-type SnO (p-SnO) offers processing simplicity, easier manipulation of doping and other properties, and reduced carrier scattering, which is favorable for carrier transport compared to multication or complex p-type oxides. However, the mono-oxide phase, SnO (p-type), is thermodynamically unstable and tends to oxidize further to form the dioxide phase, SnO (n-type).
View Article and Find Full Text PDFJ Korean Soc Radiol
May 2025
Arteriovenous fistulas (AVFs) involving the middle meningeal artery (MMA) and middle meningeal vein were initially described in 1951. Middle meningeal arteriovenous fistulas (MMAVFs) are rare abnormalities classified as dural AVFs, connecting the MMA to the nearby dural venous sinus or cortical veins. Clinical symptoms of MMAVFs include pulsatile tinnitus, headache, exophthalmos, chemosis, and diplopia.
View Article and Find Full Text PDFObjective: Shallow water diving-related spinal cord injuries (SCIs) are a significant cause of cervical spine trauma, particularly in younger individuals. This study retrospectively evaluated the outcomes of patients with SCI caused by shallow-water diving accidents at a regional trauma center on Jeju Island, South Korea. The primary aim of this study was to investigate the relationships between the timing of treatment, injury characteristics, and prognosis.
View Article and Find Full Text PDFNeurointervention
July 2025
We report a rare case of a left internal mammary artery (LIMA) originating from the left thyrocervical trunk (TCT), which arose directly from the aortic arch. A patient in their 70s presented with bilateral distal internal carotid artery aneurysms, diagnosed through computed tomography angiography performed for headache evaluation. Transfemoral cerebral angiography confirmed the aneurysms and incidentally revealed the anomalous origins of the TCT and LIMA, as well as a left vertebral artery directly arising from the aortic arch.
View Article and Find Full Text PDFJ Korean Soc Radiol
July 2024
Purpose: This multicenter prospective study aimed to evaluate the quality and diagnostic effectiveness of cerebral angiography images obtained using low-concentration iodinated contrast agents (iohexol 240 mgI/mL, iopamidol 250 mgI/mL, and iodixanol 270 mgI/mL) and to assess the safety thereof. The study addresses the need for safer contrast agent alternatives without compromising the diagnostic quality of identifying cerebrovascular disease.
Materials And Methods: Conducted in 5 medical centers in South Korea, we enrolled patients aged 19 years or older who were referred for diagnostic cerebral angiography under non-emergency conditions, excluding those with specific health conditions and sensitivities.
Purpose: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization.
Materials And Methods: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed.
A new manufacturing paradigm is showcased to exclude conventional mold-dependent manufacturing of pressure sensors, which typically requires a series of complex and expensive patterning processes. This mold-free manufacturing leverages high-resolution 3D-printed multiscale microstructures as the substrate and a gas-phase conformal polymer coating technique to complete the mold-free sensing platform. The array of dome and spike structures with a controlled spike density of a 3D-printed substrate ensures a large contact surface with pressures applied and extended linearity in a wider pressure range.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2022
It has been challenging to synthesize p-type SnO (1 < < 2) and engineer the electrical properties such as carrier density and mobility due to the narrow processing window and the localized oxygen 2p orbitals near the valence band. Herein, we report on the multifunctional encapsulation of p-SnO to limit the surface adsorption of oxygen and selectively permeate hydrogen into the p-SnO channel for thin-film transistor (TFT) applications. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements identified that ultrathin SiO as a multifunctional encapsulation layer effectively suppressed the oxygen adsorption on the back channel surface of p-SnO and selectively diffused hydrogen across the entire thickness of the channel.
View Article and Find Full Text PDFJ Cerebrovasc Endovasc Neurosurg
December 2022
The use of a balloon guide catheter (BGC) in the endovascular management of acute ischemic stroke is known to improve the efficacy and efficiency of the procedure by reducing the risk of distal embolization. During the procedure, the balloon of the catheter causes a temporary arrest of cerebral blood flow. However, failure of the balloon to deflate during the BGC procedure can result in catastrophic complications, including aggravated hypoxic damage.
View Article and Find Full Text PDFOver the past few years, many efforts have been devoted to growing single-crystal graphene due to its great potential in future applications. However, a number of issues remain for single-crystal graphene growth, such as control of nanoscale defects and the substrate-dependent nonuniformity of graphene quality. In this work, we demonstrate a possible route toward single-crystal graphene by combining aligned nucleation of graphene nanograins on Cu/Ni (111) and sequential heat treatment over pregrown graphene grains.
View Article and Find Full Text PDFMitochondrial DNA B Resour
June 2021
We have determined the complete chloroplast genome of Herbich isolated in Korea. The circular chloroplast genome of is 151,137 bp long and has four subregions: 83,041 bp of large single copy and 18,350 bp of small single copy regions are separated by 24,873 bp of inverted repeat regions including 133 genes (87 protein-coding genes, eight rRNA genes, 37 tRNAs, and one pseudogene). There are 65 to 152 single nucleotide polymorphisms and 33 to 64 insertion and deletion regions (178 bp to 372 bp in length) identified against three available chloroplast genomes of .
View Article and Find Full Text PDFOver the years, numerous studies have attempted to develop two-dimensional (2D) materials for improving both the applicability and performance of thermoelectric devices. Among the 2D materials, graphene is one of the promising candidates for thermoelectric materials owing to its extraordinary electrical properties, flexibility, and nontoxicity. However, graphene synthesized through traditional methods suffers from a low Seebeck coefficient and high thermal conductivity, resulting in an extremely low thermoelectric figure of merit (ZT).
View Article and Find Full Text PDFChemical vapor deposition has been highlighted as a promising tool for facile graphene growth in a large area. However, grain boundaries impose detrimental effects on the mechanical strength or electrical mobility of graphene. Here, we demonstrate that high-pressure hydrogen treatment in the preannealing step plays a key role in fast and large grain growth and leads to the successful synthesis of large grain graphene in 10 s.
View Article and Find Full Text PDFJ Cerebrovasc Endovasc Neurosurg
March 2020
Progressive epidural hematoma is a form of acute epidural hematoma that gradually expands from a small initial hematoma; in cases that are clinically aggravated due to the presence of a mental illness or neurological condition, patients should be surgically treated for evacuation of the hematoma, but poorer outcomes are expected if the patient has several medical co-morbidities for surgery. We experienced two cases of progressive epidural hematoma which were successfully managed by endovascular treatment: an 85-year-old male with medical co-morbidities and a 51-year-old female with a poor-grade subarachnoid hemorrhage resulting from the rupture of a dissecting aneurysm of the vertebral artery. In both cases, a middle meningeal artery embolization was performed and contrast leakage was observed and controlled using cerebral angiography, halting the progression of their epidural hematomas.
View Article and Find Full Text PDFIn this work, we present the experimental investigation on the contact resistance of graphene/single-walled carbon nanotube (SWCNT) junction using transfer length method with the simple equivalent circuit model. We find that p-n like junctions are formed in graphene/SWCNT transistors, and the contact resistance in the junction is observed to be ~ 494 and ~ 617 kΩ in case of metallic SWCNT (m-SWCNT) and semiconducting SWCNT (s-SWCNT), respectively. In addition, the contact resistance increases from 617 to 2316 kΩ as V increases from - 30 to - 10 V.
View Article and Find Full Text PDFUltra high strength V-graphene nanolayers were developed for the first time that was demonstrated to have an excellent radiation tolerance as revealed by the He(+) irradiation study. Radiation induced hardening, evaluated via nanopillar compressions before and after He(+) irradiation, is significantly reduced with the inclusion of graphene layers; the flow stresses of V-graphene nanolayers with 110 nm repeat layer spacing showed an increase of 25% while pure V showed an increase of 88% after He(+) dosage of 13.5 dpa.
View Article and Find Full Text PDFOptical transition between singlet and triplet is observed in phosphorescent platinum octaethylporphyrin (PtOEP), on a graphene substrate. PtOEP on single layer of graphene not only modulates the dominant emission wavelength but also enhances the emission intensity. This result addresses new light-matter interactions of the hybrid structure of graphene and a single molecule.
View Article and Find Full Text PDFCrystallization of materials has attracted research interest for a long time, and its mechanisms in three-dimensional materials have been well studied. However, crystallization of two-dimensional (2D) materials is yet to be challenged. Clarifying the dynamics underlying growth of 2D materials will provide the insight for the potential route to synthesize large and highly crystallized 2D domains with low defects.
View Article and Find Full Text PDFObjective: To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities.
Methods: After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft instead of sublaminar wiring. We performed this procedure in thirteen patients who had atlantoaxial instabilities and retrospectively evaluated the bone fusion rate and complications.
Objective: The purpose of this study is to compare the incidence of possible complications of cervical lateral screw fixation and the achievements of bicortical purchase using the Roy-Camille, Magerl and the modified methods.
Methods: Six fresh-frozen cervical spine segments were harvested. The Roy-Camille technique was applied to C3 and C4, and the Magerl technique was applied to C5, C6, and C7 of one side of each cadaver.