Publications by authors named "Chongxue Bie"

Objective: Phosphocreatine (PCr) and glycogen are key metabolites underpinning the skeletal muscle contractions. Simultaneous 3D imaging of these metabolites is valuable for understanding heterogeneous energetic events. While saturation transfer (ST) MRI can detect metabolites, 3D ST acquisition generally requires long scan times.

View Article and Find Full Text PDF

Background: Brain temperature signifies the thermal homeostasis of the tissue, and may serve as a marker for neuroprotective therapy. Currently, it remains challenging to map the human brain temperature with high spatial resolution. The thermal dependence of chemical exchange saturation transfer (CEST) effects of endogenous labile protons may provide a promising mechanism for the absolute brain temperature imaging.

View Article and Find Full Text PDF

Probing regional glycogen metabolism in humans non-invasively has been challenging due to a lack of sensitive approaches. Here we studied human muscle glycogen dynamics post-exercise with a spatial resolution of millimeters and temporal resolution of minutes, using relayed nuclear Overhauser effect (glycoNOE) MRI. Data at 5T showed a homogeneous distribution of glycogen in resting muscle, with an average concentration of 99 ± 13 mM.

View Article and Find Full Text PDF
Article Synopsis
  • There is a growing need for non-invasive methods to monitor glycogen storage diseases (GSD), specifically utilizing saturation transfer (ST) MRI to observe changes in muscle glycogen in a GSD II mouse model.
  • The research involved measuring various metabolites in the skeletal muscles of both healthy and GSD II mice at different ages, assessing the accumulation and levels of muscle glycogen and energy metabolites.
  • Results showed that while glycogen accumulation increased in younger GSD II mice, it plateaued in adults, indicating potential biomarkers for monitoring disease progression and treatment efficacy in GSDs.
View Article and Find Full Text PDF

Chemical exchange saturation transfer (CEST) MRI at 3 T suffers from low specificity due to overlapping CEST effects from multiple metabolites, while higher field strengths (B) allow for better separation of Z-spectral "peaks," aiding signal interpretation and quantification. However, data acquisition at higher B is restricted by equipment access, field inhomogeneity and safety issues. Herein, we aim to synthesize higher-B Z-spectra from readily available data acquired with 3 T clinical scanners using a deep learning framework.

View Article and Find Full Text PDF

Purpose: Glycogen storage disease type III (GSD III) is a rare inherited metabolic disease characterized by excessive accumulation of glycogen in liver, skeletal muscle, and heart. Currently, there are no widely available noninvasive methods to assess tissue glycogen levels and disease load. Here, we use glycogen nuclear Overhauser effect (glycoNOE) MRI to quantify hepatic glycogen levels in a mouse model of GSD III.

View Article and Find Full Text PDF

Background: Quantification of chemical exchange saturation transfer (CEST) magnetic resonance signals is challenging due to contamination from coexisting effects, including the direct water effect and asymmetric magnetization transfer. Fitting-based analysis allows the calculation of multiple types of signals from the line shape of Z-spectra. However, the conventional voxelwise method has several drawbacks, including its long computation time and its susceptibility to image noise and Z-spectra oscillations, and it is difficult to determine the initial fitting parameters.

View Article and Find Full Text PDF

Background And Objectives: In diffuse glioma patients, Lys-27-Met mutations in histone 3 genes (H3K27M) are associated with an aggravated prognosis and further decreased overall survival. By using frequency importance analysis on chemical exchange saturation transfer (CEST) MRI, this study aimed to assess the predictability of the H3K27M status in diffuse glioma patients.

Methods: Twenty-two patients diagnosed with diffuse glioma, with a known H3K27M status, were included in the present study.

View Article and Find Full Text PDF

Chemical exchange saturation transfer (CEST) MRI has generated great interest for molecular imaging applications because it can image low-concentration solute molecules in vivo with enhanced sensitivity. CEST effects are detected indirectly through a reduction in the bulk water signal after repeated perturbation of the solute proton magnetization using one or more radiofrequency (RF) irradiation pulses. The parameters used for these RF pulses-frequency offset, duration, shape, strength, phase, and interpulse spacing-determine molecular specificity and detection sensitivity, thus their judicious selection is critical for successful CEST MRI scans.

View Article and Find Full Text PDF
Article Synopsis
  • Mannitol is used to reduce intracranial pressure and create osmotic blood-brain barrier openings, but a safer, non-invasive monitoring method for its dosing is needed.
  • The study developed a label-free MRI technique, utilizing Chemical Exchange Saturation Transfer (CEST), to measure mannitol levels in the brain after administration in rat models.
  • Results showed that CEST MRI effectively detected mannitol in the brain, with high doses leading to accumulation, and this method could help optimize mannitol usage for enhanced safety and effectiveness in clinical settings.
View Article and Find Full Text PDF

Purpose: Acquisition of high-resolution Z-spectra for CEST or magnetization transfer contrast (MTC) MRI requires excessive scan times. Ultrafast Z-spectroscopy (UFZ) has been proposed to address this; however, the quality of in vivo UFZ spectra has been insufficient. Here, we present a simple approach to improve this.

View Article and Find Full Text PDF

Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low-concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon-bound protons in mobile macromolecules in solution.

View Article and Find Full Text PDF

Purpose: Saturation transfer MRI has previously been used to probe molecular binding interactions with signal enhancement via the water signal. Here, we detail the relayed nuclear overhauser effect (rNOE) based mechanisms of this signal enhancement, develop a strategy of quantifying molecular binding affinity, i.e.

View Article and Find Full Text PDF

Chemical exchange saturation transfer (CEST) magnetic resonance imaging has shown promise for classifying tumors based on their aggressiveness, but CEST contrast is complicated by multiple signal sources and thus prolonged acquisition times are often required to extract the signal of interest. We investigated whether deep learning could help identify pertinent Z-spectral features for distinguishing tumor aggressiveness as well as the possibility of acquiring only the pertinent spectral regions for more efficient CEST acquisition. Human breast cancer cells, MDA-MB-231 and MCF-7, were used to establish bi-lateral tumor xenografts in mice to represent higher and lower aggressive tumors, respectively.

View Article and Find Full Text PDF

Background: Chemical exchange saturation transfer (CEST) MRI is a promising approach for detecting biochemical alterations in cancers and neurological diseases, but the quantification can be challenging. Among numerous quantification methods, Lorentzian difference (LD) is relatively simple and widely used, which employs Lorentzian line-shape as a reference to describe the direct saturation (DS) of water and takes account of difference against experimental CEST spectra data. However, LD often overestimates CEST and nuclear overhauser enhancement (NOE) effects.

View Article and Find Full Text PDF

Background: Chemical exchange saturation transfer (CEST) MRI requires the acquisition of multiple saturation-weighted images and can last several minutes. Misalignments among these images, which are often due to the inevitable motion of the subject, will corrupt CEST contrast maps and result in large quantification errors. Therefore, the registration of the CEST series is critical.

View Article and Find Full Text PDF