Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Hand gesture recognition(HGR) is a key technology in human-computer interaction and human communication. This paper presents a lightweight, parameter-free attention convolutional neural network (LPA-CNN) approach leveraging Gramian Angular Field(GAF)transformation of A-mode ultrasound signals for HGR. First, this paper maps 1-dimensional (1D) A-mode ultrasound signals, collected from the forearm muscles of 10 healthy participants, into 2-dimensional (2D) images. Second, GAF is selected owing to its higher sensitivity against Markov Transition Field (MTF) and Recurrence Plot (RP) in HGR. Third, a novel LPA-CNN consisting of four components, i.e., a convolution-pooling block, an attention mechanism, an inverted residual block, and a classification block, is proposed. Among them, the convolution-pooling block consists of convolutional and pooling layers, the attention mechanism is applied to generate 3-D weights, the inverted residual block consists of multiple channel shuffling units, and the classification block is performed through fully connected layers. Fourth, comparative experiments were conducted on GoogLeNet, MobileNet, and LPA-CNN to validate the effectiveness of the proposed method. Experimental results show that compared to GoogLeNet and MobileNet, LPA-CNN has a smaller model size and better recognition performance, achieving a classification accuracy of 0.98 ±0.02. This paper achieves efficient and high-accuracy HGR by encoding A-mode ultrasound signals into 2D images and integrating the LPA-CNN model, providing a new technological approach for HGR based on ultrasonic signals.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2025.3608180DOI Listing

Publication Analysis

Top Keywords

a-mode ultrasound
16
ultrasound signals
16
hand gesture
8
encoding a-mode
8
convolution-pooling block
8
attention mechanism
8
inverted residual
8
residual block
8
classification block
8
block consists
8

Similar Publications

Hand gesture recognition(HGR) is a key technology in human-computer interaction and human communication. This paper presents a lightweight, parameter-free attention convolutional neural network (LPA-CNN) approach leveraging Gramian Angular Field(GAF)transformation of A-mode ultrasound signals for HGR. First, this paper maps 1-dimensional (1D) A-mode ultrasound signals, collected from the forearm muscles of 10 healthy participants, into 2-dimensional (2D) images.

View Article and Find Full Text PDF

Feasibility, reliability, and clinical utility of skeletal muscle assessment with A-mode ultrasonography in hospitalized patients with burns.

Burns

August 2025

Alliance of Dutch Burn Care, Burn Centre Groningen, Martini Hospital, Groningen, the Netherlands; Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Groningen, the Netherlands; University of Groningen, University Medical Center Groningen, Department

Objectives: Amplitude-mode (A-mode) ultrasonography is a promising technique to monitor loss and recovery of skeletal muscle in patients with burns. However, its clinimetric properties are unknown. Therefore, we determined its feasibility, interrater, and intrarater reliability, and clinical utility.

View Article and Find Full Text PDF

Background: An in-depth analysis of body composition (BC) is fundamental for the assessment of nutritional status. A multifactorial approach is important for this assessment, integrating parameters and measurements obtained through different techniques, most notably bioelectrical impedance analysis (BIA) and ultrasound. In this study, we aimed to evaluate associations between BIA parameters and ultrasound measurements.

View Article and Find Full Text PDF

Background & Aims: Considering the importance of accurate methods for assessing body fat in older adults, this study aimed to develop and validate equations for estimating body fat percentage (%BF) using portable A-mode ultrasound (US) and anthropometric data in older adults.

Methods: A total of 149 healthy older adults (≥60 years old) were included in the cross-sectional study. Three-fourths (n = 111) were randomly assigned to the development sample and one-fourth to the validation sample (n = 38).

View Article and Find Full Text PDF

The reduction of skeletal muscle mass in catabolic conditions, such as cancer, is linked to adverse outcomes. Assessing muscle health provides valuable prognostic information, aiding therapeutic decisions to improve survival and quality of life. A-mode ultrasound is a portable, low-cost tool for body composition assessment, particularly useful in resource-limited settings.

View Article and Find Full Text PDF