Article Abstract

Background: Accurate prediction of lung tumor motion and deformation (LTMD) is essential for precise radiotherapy. However, existing models often rely on static, population-based material parameters, overlooking patient-specific and time-varying lung biomechanics. Personalized dynamic models that capture temporal changes in lung elasticity are needed to improve LTMD prediction and guide treatment planning more effectively.

Purpose: This study aims to develop a patient-specific, time-varying biomechanical model to predict LTMD more accurately.

Methods: Four-dimensional computed tomography (4DCT) images from 27 patients, each with 10 breathing phases, were analyzed. A finite element model was developed, modeling lung as a hyper-elastic material and tumor as linear elastic. Lung elasticity parameters, including Young's modulus (E) and Poisson's ratio (v), were optimized for each phase using Efficient Global Optimization algorithm. Four functions were tested to model the variation of E and v across different phases. For each patient, average values of these parameters were computed, and their correlation with 11 clinical features was analyzed. The model's accuracy in predicting LTMD was evaluated using tumor center of mass motion error (ΔTCM) and volumetric Dice similarity coefficient (vDSC). Factors influencing the model's accuracy were investigated. Specifically, lung surface traction vector fields (STVFs) were calculated during the transition from end-expiration to end-inspiration phases, and their relationship with LTMD was also analyzed.

Results: The first-order Fourier function provided the best fit among four tested functions, with average R-squared values of 0.93 ± 0.03 for E and 0.91 ± 0.03 for v. The average values of E and v were significantly correlated with patient age. The model showed a mean ΔTCM of 1.47 ± 0.68 mm and a mean vDSC of 0.93 ± 0.02. A negative correlation was found between tumor deformation vDSC and ΔTCM (r = -0.55, p < 0.05). Higher STVFs were observed near diaphragm and intercostal muscles, with correlations between STVFs and tumor motion amplitude (r ≥ 0.92, p < 0.05).

Conclusions: These findings offer new insights into developing personalized, time-varying motion management strategies of lung tumors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12409114PMC
http://dx.doi.org/10.1002/mp.18086DOI Listing

Publication Analysis

Top Keywords

time-varying biomechanical
8
biomechanical model
8
lung tumor
8
tumor motion
8
motion deformation
8
patient-specific time-varying
8
lung elasticity
8
average values
8
model's accuracy
8
lung
7

Similar Publications

Background: Accurate prediction of lung tumor motion and deformation (LTMD) is essential for precise radiotherapy. However, existing models often rely on static, population-based material parameters, overlooking patient-specific and time-varying lung biomechanics. Personalized dynamic models that capture temporal changes in lung elasticity are needed to improve LTMD prediction and guide treatment planning more effectively.

View Article and Find Full Text PDF

Introduction: Access to custom 3D printed pelvic implants (3DPI) is improving for application in both arthroplasty revision and tumour reconstruction. There is limited evidence regarding the safety and outcomes of such implants for large bony defects of the pelvis. The aim of this study is to report the incidence of complications, patient mortality and implant survival following pelvic reconstruction using custom 3Dprinted prostheses in the setting of extensive pelvic bone defects following pelvic tumour resection or failure of total hip arthroplasty (THA).

View Article and Find Full Text PDF

Safety evaluation for heavy vehicle drivers using extreme value model based on the multi-source sensing data.

Accid Anal Prev

October 2025

School of Transportation, Southeast University, Nanjing 211189, China; Jiangsu Key Laboratory of Urban ITS, School of Transportation, Southeast University, Nanjing 211189, China.

Increasingly, the collection of multi-source sensing data from heavy vehicles through intelligent networked platforms has become prevalent for safety management and supervision. However, practical approaches for crash risk management and safety evaluation have not been fully developed to capitalize on this high-value driving data. This study proposed a safety evaluation framework for heavy vehicles using the extreme value modeling approach.

View Article and Find Full Text PDF

Design and control of a permanent magnet-based robotic system for navigating tetherless magnetic devices in viscous environments.

Sci Rep

August 2025

Robotics and Mechatronics Research Group, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, 7500 AE, The Netherlands.

Tetherless magnetic devices (TMDs) that are driven using external stimuli have potential applications in minimally invasive surgery. The magnetic field produced by electromagnet- and permanent magnet-based robotic systems is a viable option as an external stimulus to enable the motion of a TMD in viscous and viscoelastic media. In order to realize the navigation of TMDs in fluidic environments, we design a permanent magnet-based robotic system with an open configuration using two synchronized rotating magnetic dipoles to generate time-varying rotating magnetic fields.

View Article and Find Full Text PDF

Push-Off Efficacy in Parkinson's Disease compared to healthy controls and its relationship with step length.

J Biomech

October 2025

School of Medicine and Surgery, University of Milano Bicocca, Monza, Italy; Doctor of Physical Therapy Program, Department of Kinesiology, University of Connecticut, Storrs, CT, USA. Electronic address:

The reduction of step length is one of the most common gait impairments in patients with Parkinson's Disease (PD). However, the neuromuscular strategies associated to this gait impairment are still unclear. This study aimed to investigate the potential relationship between muscle activation and step length in PD and healthy controls.

View Article and Find Full Text PDF