Purpose This foundational study aims to support the development of regional Diagnostic Reference Levels (DRLs) for mammography screening in India by estimating Mean Glandular Dose (MGD) using appropriate breast-equivalent phantoms across Computed Mammography (CR), Digital Mammography (DR), and Digital Breast Tomosynthesis (DBT) systems. Additionally, system-displayed MGD values were compared with calculated MGDs to evaluate their accuracy for routine clinical use. Methods A total of 5,000 mammographic views were collected across CR, DR, and DBT units. For each unit and phantom thickness, ten Entrance Surface Air Kerma (ESAK) measurements were performed under clinical settings using a calibrated solid-state dosimeter (AccuGold+, Radcal, USA). Breast-equivalent slab phantoms (Sun Nuclear, USA), ranging from 30 mm to 90 mm, were used to simulate varying glandular compositions. Standard American College of Radiology (ACR) and DBT phantoms were employed to ensure consistent imaging conditions. MGDs were derived from ESAK values using IAEA recommended conversion factors. For DR and DBT systems, calculated MGDs were compared with system displayed values. The 75th percentile MGDs for each phantom thickness were used to propose regional DRLs, in line with ICRP Publication 135 and IAEA Human Health Report No. 77. Results At the standard 60 mm compressed breast thickness, the 75th percentile MGDs were 2.58 ± 0.38 mGy (CR), 1.68 ± 0.86 mGy (DR), and 2.66 ± 0.78 mGy (DBT). System-displayed MGDs in DR and DBT were 13-17% higher than calculated values. Conclusion This study presents a scalable, reproducible framework for establishing regional, thickness-specific DRLs in India, supporting dose optimization and quality assurance in mammography practice.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/ae02a4DOI Listing

Publication Analysis

Top Keywords

glandular dose
8
breast-equivalent phantoms
8
foundational study
8
mammography digital
8
dbt systems
8
calculated mgds
8
phantom thickness
8
75th percentile
8
percentile mgds
8
dbt
6

Similar Publications

Background: In contrast-enhanced digital mammography (CEDM) and contrast-enhanced digital breast tomosynthesis (CEDBT), low-energy (LE) and high-energy (HE) images are acquired after injection of iodine contrast agent. Weighted subtraction is then applied to generate dual-energy (DE) images, where normal breast tissues are suppressed, leaving iodinated objects enhanced. Currently, clinical systems employ a dual-shot (DS) method, where LE and HE images are acquired with two separate exposures.

View Article and Find Full Text PDF

Purpose This foundational study aims to support the development of regional Diagnostic Reference Levels (DRLs) for mammography screening in India by estimating Mean Glandular Dose (MGD) using appropriate breast-equivalent phantoms across Computed Mammography (CR), Digital Mammography (DR), and Digital Breast Tomosynthesis (DBT) systems. Additionally, system-displayed MGD values were compared with calculated MGDs to evaluate their accuracy for routine clinical use. Methods A total of 5,000 mammographic views were collected across CR, DR, and DBT units.

View Article and Find Full Text PDF

Introduction: Diagnostic reference levels (DRLs) are one of the most important radiation protection methods in medical imaging to help optimize radiation exposure during imaging procedures. The study aimed to establish national DRL for digital mammography (DM) and digital breast tomosynthesis (DBT) in Jordan, considering variations in compressed breast thickness (CBT) and breast density.

Methodology: The exposure parameters, average glandular dose (AGD), CBT, breast density, and viewing projection were extracted.

View Article and Find Full Text PDF

Background: Mammography is a critical tool for early breast cancer detection, but its use of ionizing radiation necessitates careful monitoring and optimization of patient exposure to ensure safety. Conventional methods for reporting diagnostic reference levels (DRLs) rely on wide compressed breast thickness (CBT) ranges, which lack the precision to account for individual variations, limiting their effectiveness in optimizing mammographic radiation doses.

Purpose: To develop an equation-based approach that provides a DRL for any given CBT.

View Article and Find Full Text PDF

Purpose: To determine whether low-energy (LE) images acquired during contrast-enhanced mammography (CEM) are diagnostically and technically comparable to full-field digital mammography (FFDM) using standardised image quality and lesion conspicuity metrics.

Materials And Methods: In this retrospective study, 268 women (mean age: 44.6 years) who underwent both FFDM and CEM imaging, were included.

View Article and Find Full Text PDF