Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Colorectal cancer (CRC) incidence is rising globally, intensifying pressure on endoscopy services. Colon capsule endoscopy (CCE) offers a non-invasive alternative. Despite several systematic reviews showing reasonable polyp detection rates, clinical scepticism remains.

Objectives: This meta-review and umbrella meta-analysis aim to synthesise evidence on CCE's diagnostic accuracy in polyp and CRC detection, using CT colonography or colonoscopy as the reference standard.

Methods: We conducted a systematic search of EMBASE, MEDLINE and PubMed for systematic reviews evaluating the diagnostic accuracy of CCE in detecting polyps and CRC. A qualitative thematic review and synthesis were conducted following PRISMA guidelines. A bivariate generalised linear mixed model with random effects was used for pooled diagnostic accuracy estimates, and meta-regression was performed using restricted maximum likelihood estimation.

Results: Nine systematic reviews encompassing 28 unique studies (3472 participants) were included. For polyps of any size, the pooled per-patient sensitivity was 0.79 (95% CI: 0.69-0.86), specificity was 0.77 (95% CI: 0.71-0.82), and the area under the curve (AUC) was 0.81. For polyps ⩾6 mm, sensitivity and specificity were 0.80 and 0.87 (AUC 0.81), and for polyps ⩾10 mm, 0.88 and 0.95 (AUC 0.95), respectively. Second-generation CCE (CCE2) improved diagnostic accuracy across all polyp sizes. For polyps of any size, CCE2 achieved a sensitivity of 0.90, specificity of 0.81 and AUC of 0.82. For polyps ⩾ 6 mm and ⩾10 mm, AUCs were 0.92 and 0.94, respectively. CCE2 showed high sensitivity for detecting any polyp size and polyps ⩾6 mm, with low heterogeneity ( > 0.05,  < 25%). CRC detection sensitivity was 0.96 (95% CI: 0.73-1.00) after excluding cases where the capsule failed to reach the rectum due to battery exhaustion.

Conclusion: CCE2 has high diagnostic accuracy for polyps and colorectal cancer detection. While technical challenges persist, CCE2 shows promise as a complementary diagnostic tool to help address the increasing demands for endoscopy services.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12398663PMC
http://dx.doi.org/10.1177/26317745251370845DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
systematic reviews
12
colon capsule
8
capsule endoscopy
8
umbrella meta-analysis
8
accuracy polyp
8
polyps size
8
auc 081
8
081 polyps
8
polyps ⩾6 mm
8

Similar Publications

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.

Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.

View Article and Find Full Text PDF

Background: Current scoring systems for hypertriglyceridaemia-induced acute pancreatitis (HTG-AP) severity are few and lack reliability. The present work focused on screening predicting factors for HTG-SAP, then constructing and validating the visualization model of HTG-AP severity by combining relevant metabolic indexes.

Methods: Between January 2020 and December 2024, retrospective clinical information for HTG-AP inpatients from Weifang People's Hospital was examined.

View Article and Find Full Text PDF

Obsessive-compulsive disorder (OCD) is a chronic and disabling condition affecting approximately 3.5% of the global population, with diagnosis on average delayed by 7.1 years or often confounded with other psychiatric disorders.

View Article and Find Full Text PDF

Background: Thyroid nodules (TNs) are frequent and often benign. Accurately differentiating between benign and malignant nodules is crucial for proper management. This research aims to use ultrasonography to examine TNs and identify possible risk factors in order to improve patient outcomes and diagnostic accuracy.

View Article and Find Full Text PDF