Article Abstract

Aim: This study aimed to evaluate the multifaceted clinical utility of the RUBY phantom as a comprehensive quality assurance (QA) platform in high-precision radiotherapy, particularly for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). The objective was to validate its performance in patient positioning, imaging system accuracy, isocenter congruency, and treatment plan verification across various complex clinical scenarios.

Materials And Methods: A series of QA workflows were conducted using the RUBY phantom and its dedicated modular inserts. These included CBCT and MV/kV planar imaging for patient alignment, the Winston-Lutz insert for isocenter verification, end-to-end testing for full-chain validation, and multi-metastasis and patient-specific inserts for point dose verification. Plans were created in Eclipse TPS (v15.6) and delivered using a Varian TrueBeam STx linear accelerator with high-definition MLC. PTW Semiflex 3D and PinPoint 3D ionization chambers were used for all dosimetric verifications.

Results: CBCT- and planar image-guided alignments showed sub-millimetric deviations, with post-correction alignment verified through coincident laser and surface markers. Winston-Lutz testing across various angles demonstrated maximal deviations of ≤ 0.4 mm, which was within TG-142 recommendations. Point dose measurements for 61 SRS plans showed agreement within ± 3% of TPS calculations. End-to-end testing revealed dose discrepancies of < 1% in both coplanar and non-coplanar beam arrangements. Multi-target plans using single- and multi-isocenter approaches showed deviations of - 0.23% to - 0.50%, confirming excellent dosimetric and geometric accuracy.

Conclusion: The RUBY phantom demonstrated exceptional precision, reproducibility, and clinical adaptability across a spectrum of advanced radiotherapy QA tasks. Its integration enables the end-to-end validation of modern treatment protocols, ensuring alignment, imaging, and accuracy of dose delivery. These findings establish the RUBY phantom as a cornerstone QA solution for enhancing safety, efficacy, and reliability in high-precision radiotherapy.

Download full-text PDF

Source
http://dx.doi.org/10.1186/s43046-025-00314-xDOI Listing

Publication Analysis

Top Keywords

quality assurance
8
ruby phantom
8
end-to-end testing
8
point dose
8
clinical implementation
4
implementation multifaceted
4
multifaceted quality
4
assurance phantom
4
phantom high-precision
4
high-precision radiation
4

Similar Publications

Association Between In-Hospital Applications for Long-Term Care Services and Hospital Length of Stay Among Older Adults: Ecological Cross-Sectional Study.

JMIR Form Res

September 2025

Department of Health Economics, Center for Gerontology and Social Science, National Center for Geriatrics and Gerontology, Research Institute, Obu, Japan.

Background: Delayed discharge among older patients presents a major challenge for the efficiency of health service delivery. Prolonged hospitalizations limit bed turnover, increase costs, and reduce the availability of hospital resources. In Japan, older adults must undergo a formal care needs certification process to access public long-term care (LTC) services.

View Article and Find Full Text PDF

Clinical practice guidelines for esophagogastric junction cancer (EGJ GLs) were published in 2023. In order to evaluate how EGJ GLs have been adopted into clinical practice worldwide and to identify any outstanding clinical questions to be addressed in the next edition, this survey was conducted. An electronic questionnaire was developed.

View Article and Find Full Text PDF

Purpose: To develop and validate a deep learning-based model for automated evaluation of mammography phantom images, with the goal of improving inter-radiologist agreement and enhancing the efficiency of quality control within South Korea's national accreditation system.

Materials And Methods: A total of 5,917 mammography phantom images were collected from the Korea Institute for Accreditation of Medical Imaging (KIAMI). After preprocessing, 5,813 images (98.

View Article and Find Full Text PDF

Background: In pediatric intensive care units, pain, sedation, delirium, and iatrogenic withdrawal syndrome (IWS) must be managed as interrelated conditions. Although clinical practice guidelines (CPGs) exist, new evidence needs to be incorporated, gaps in recommendations addressed, and recommendations adapted to the European context.

Objective: This protocol describes the development of the first patient- and family-informed European guideline for managing pain, sedation, delirium, and IWS by the European Society of Paediatric and Neonatal Intensive Care.

View Article and Find Full Text PDF

Neuroblastoma is the most common extracranial solid tumor in children, requiring multidisciplinary treatment, including radiotherapy, which is primarily applied in the high-risk group to prevent disease progression. The review highlights indications for radiotherapy, its role in multimodal treatment, and addresses aspects of radiotherapy planning, including target volume definition, prescribed radiation doses, optimal timing for radiotherapy implementation, and potential side effects. Particular attention is drawn to the lack of consensus regarding the necessity of an additional radiation dose for persistent residual disease in the primary tumor and the irradiation of metastatic sites remaining after induction therapy.

View Article and Find Full Text PDF