98%
921
2 minutes
20
A well-known and accepted aerosol measurement technique, the scanning mobility particle sizer (SMPS), is applied to characterize colloidally dispersed nanoparticles. To achieve a transfer from dispersed particles to aerosolized particles, a newly developed nebulizer (N) is used that, unlike commonly used atomizers, produces significantly smaller droplets and therefore reduces the problem of the formation of residual particles. The capabilities of this new instrument combination (N + SMPS) for the analysis of dispersions were investigated, using three different dispersions, gold-PVP nanoparticles (∼20 nm), silver-PVP nanoparticles (∼70 nm) and their 1 : 1 ( : ) mixture. The results are compared to scanning electron microscopy (SEM) measurements and two frequently applied techniques for characterizing colloidal systems: Dynamic light scattering (DLS) and analytical disc centrifugation (ADC). The differences, advantages and disadvantages of each method are discussed, especially with respect to the size resolution of the techniques and their ability to distinguish the particle sizes of the mixed dispersion. While DLS is, as expected, unable to resolve the binary dispersion, SEM, ADC and SMPS are able to give quantitative information on the two particle sizes. However, while the high-resolving ADC is limited due to the dependency on a predefined density of the investigated system, the transfer of dispersed particles into an aerosol and subsequent analysis with SMPS are an adequate way to characterize binary systems, independent of the density of concerned particles, but matching the high resolution of the ADC. We show that it is possible to use the well-established aerosol measurement technique (N + SMPS) in colloid science with all its advantages concerning size resolution and accuracy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c4ay01203h | DOI Listing |
J Occup Environ Hyg
September 2025
National Institute of Occupational Health, Oslo, Norway.
As the range of allergens continues to expand and the food industry evolves, there is a growing need for more efficient, affordable, and comprehensive methods to monitor protein exposures. This study aimed to assess the concentrations of inhalable aerosols and soluble proteins (SP) in food manufacturing environments. Additionally, the study sought to optimize the extraction methods for determining SP across diverse food matrices.
View Article and Find Full Text PDFEnviron Sci Technol
September 2025
Institut de Chimie de Clermont-Ferrand, Université Clermont Auvergne, CNRS, UMR 6296, Clermont-Ferrand 63000, France.
Pesticide contamination is a growing and alarming concern for both the environment and human health. Widely used in agriculture to control pests and disease carriers, pesticides undergo extensive long-range atmospheric transport in the gas phase, in aerosols, and, as shown here, in clouds. We measured the concentration of 32 pesticides at the puy de Dôme observatory (France) in the sub μg L to μg L range in cloud water, largely arising from regional to long-range transport that also involves pesticides currently banned for agricultural use in France.
View Article and Find Full Text PDFAnn Work Expo Health
September 2025
Laboratoire de Métrologie des Aérosols, INRS, 54519 Vandœuvre-lès-Nancy Cedex, France.
Endotoxins are components of the outer membrane of bacteria that can become airborne during aerosol-generating work activities and cause adverse effects on workers' health. Filtration is the sampling method recommended by the EN 14031 standard for endotoxin measurements in workplace atmospheres. However, there are still differences in terms of practice regarding certain parameters of the measurement method.
View Article and Find Full Text PDFFront Public Health
September 2025
Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Objectives: This study aimed to quantify aerosol and microbial exposure levels during different working hours, analyze temporal air pollution trends in the endoscopy suite, and provide evidence to optimize infection prevention strategies.
Methods: A portable laser particle counter and an airborne bacteria sampler were used to measure aerosol particle concentrations and microbial loads at four time points: before the commencement of work (baseline), and 1, 2, and 3 h after work initiation. Continuous data collection was conducted over 10 consecutive working days.
Commun Med (Lond)
September 2025
Regional Environment Conservation Division, National Institute for Environmental Studies, Tsukuba, Japan.
Background: Particulate matter with an aerodynamic diameter of ≤2.5 µm (PM) is a heterogeneous mixture, and specific substances that affect cardiovascular events remain unknown. We aimed to examine the association of short-term exposure to PM and its components with hospital admissions for acute myocardial infarction (AMI).
View Article and Find Full Text PDF