Article Abstract

Objectives: This study aimed to quantify aerosol and microbial exposure levels during different working hours, analyze temporal air pollution trends in the endoscopy suite, and provide evidence to optimize infection prevention strategies.

Methods: A portable laser particle counter and an airborne bacteria sampler were used to measure aerosol particle concentrations and microbial loads at four time points: before the commencement of work (baseline), and 1, 2, and 3 h after work initiation. Continuous data collection was conducted over 10 consecutive working days. Air quality assessments were performed through scientific evaluation according to relevant international and national standards.

Results: Qualified rates for aerosols ≥0.5 μm increased by 20-30% during the 3 working hours compared to baseline levels. Microbial qualified rates remained at 100% throughout the study period. Aerosol concentrations across all particle sizes significantly increased with working hours ( 0.01). The growth rate of 5-10 μm aerosols was higher than that of 0.3-5 μm particles ( 0.01). After 3 h, concentrations of 0.5-25 μm and 0.3-10 μm aerosols increased by 1.48-fold and 1.3-fold compared to baseline values. Total microbial colonies positively correlated with work duration, polyp detection frequency, biopsy procedures performed, and procedure duration ( 0.05). Microbial analysis identified 12 species, predominantly bacteria (79.6%) and fungi (20.4%).

Conclusion: This study highlights trends in aerosol and microbial contamination over time and identifies four factors influencing microbial counts in the endoscopy suite. We propose some recommendations to reduce exposure risks for HCWs and patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12406866PMC
http://dx.doi.org/10.3389/fpubh.2025.1634327DOI Listing

Publication Analysis

Top Keywords

aerosol microbial
12
working hours
12
microbial
8
microbial exposure
8
endoscopy suite
8
qualified rates
8
compared baseline
8
quantifying aerosol
4
exposure healthcare
4
healthcare workers
4

Similar Publications

Quantifying aerosol and microbial exposure of healthcare workers in endoscopy suites: a time-based study.

Front Public Health

September 2025

Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.

Objectives: This study aimed to quantify aerosol and microbial exposure levels during different working hours, analyze temporal air pollution trends in the endoscopy suite, and provide evidence to optimize infection prevention strategies.

Methods: A portable laser particle counter and an airborne bacteria sampler were used to measure aerosol particle concentrations and microbial loads at four time points: before the commencement of work (baseline), and 1, 2, and 3 h after work initiation. Continuous data collection was conducted over 10 consecutive working days.

View Article and Find Full Text PDF

Stemflow, the concentrated fraction of rainfall that drains down tree trunks, can translocate canopy biota to the forest floor, but its eukaryotic composition remains uncharacterized via eDNA methods. We collected stemflow from 18 Fagus grandifolia (American beech) trees during ten storms in northeastern Ohio (USA) and analyzed 18S rRNA eDNA to resolve transported microbial-eukaryote communities. Over 12 million reads (83 samples) revealed 920 zero-radius OTUs spanning fungi, algae, protists, and metazoans.

View Article and Find Full Text PDF

Occupants and surface types drive microbial dynamics in controlled indoor environments.

Environ Microbiome

September 2025

Center for the Planetary Health and Innovation Science (PHIS), The IDEC Institute, Hiroshima University, Higashi-Hiroshima, 739-8530, Japan.

Background: Indoor microbial communities play a critical role in influencing indoor environmental quality and human health and are shaped by occupant activity, surface characteristics, and environmental conditions. While previous studies have examined these factors individually, systematic evaluations of their combined interactions, particularly involving Heating, Ventilation, and Air Conditioning (HVAC) and drainage systems, remain limited. This controlled, long-term (1.

View Article and Find Full Text PDF

Metabarcoding-Based Seasonal Assessment of Airborne Microbial Communities in PM₁₀ Samples from a Semi-Urban Region in Tamil Nadu, India.

Environ Monit Assess

September 2025

Department of Genetic Engineering, School of Bioengineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu Dt, 603203, Tamil Nadu, India.

Airborne microbial communities show marked seasonal variability, with implications for both environmental processes and public health. In this study, metagenomic sequencing was applied to characterize airborne microbiota across four distinct seasons in India-winter (Sw), summer (Ss), southwest monsoon (Ssw), and northeast monsoon (Sne). Distinct shifts in dominant bacterial taxa were observed.

View Article and Find Full Text PDF

Background: Textiles used in healthcare settings can act as reservoirs for microbial contamination. However, their potential role in the transmission of healthcare-associated infections (HAIs) remains underexplored.

Methods: This scoping review mapped existing evidence on the composition and management of hospital textiles in relation to HAI prevention.

View Article and Find Full Text PDF