A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Self-Enhanced Ratiometric ECL Strategy Based on a Dual-Emission Ce/Tb-MOF Luminophore with Spatially Resolved Coreactant Delivery for Ultrasensitive Pro-GRP Detection. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dual-signal-output ratiometric electrochemiluminescence (ECL) platforms offer a promising solution to address the instability and inaccuracies associated with single-signal ECL detection. However, most existing ratiometric systems still rely on two independent luminophores, inevitably increasing the system complexity and compromising the detection accuracy. In this study, a bimetallic dual-ligand ECL luminophore, Ce/Tb-MOF, was synthesized via a solvothermal approach, exhibiting distinct anodic and cathodic ECL emissions from a single luminophore. To spatially regulate signal generation and avoid the complications of coreactant mixing, we designed a beacon nanostructure, TPA-β-CD@Au, that locally introduces the anodic coreactant tripropylamine (TPA) upon target binding. This enabled the implementation of a ″Reverse Regulation of Anodic/Cathodic Signals″ strategy, wherein target recognition simultaneously suppresses cathodic emission and enhances anodic emission, achieving internally calibrated signal output. Based on this mechanism, a highly sensitive ECL immunosensor was developed for the detection of Pro-gastrin-releasing peptide (Pro-GRP). The sensor exhibited excellent analytical performance, including a broad dynamic range (100 fg/mL to 100 ng/mL), a low detection limit of 52.4 fg/mL, and strong anti-interference capability. This work presents a robust and simplified ratiometric ECL platform and provides valuable insights into the rational design of multifunctional MOF-based biosensors for clinical diagnostics.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.5c04144DOI Listing

Publication Analysis

Top Keywords

ratiometric ecl
8
luminophore spatially
8
ecl
7
detection
5
self-enhanced ratiometric
4
ecl strategy
4
strategy based
4
based dual-emission
4
dual-emission ce/tb-mof
4
ce/tb-mof luminophore
4

Similar Publications