Article Abstract

Background: False-positive (FP) alerts from implantable loop recorders increase clinical workload and may delay appropriate intervention. AccuRhythm AI, a cloud-based filtering algorithm, is designed to reduce these alerts in Reveal LINQ and LINQ II devices. This study assessed the algorithm's effect on FP and clinician burden reduction, with a focus on the influence of R-wave sensing amplitude.

Methods: This multicentre, retrospective study included 800 patients with either Reveal LINQ or LINQ II. We analysed automated artificial intelligence (AI) reports and compared FP rates and transmission burden before and after software-based AI activation in the subset of Reveal LINQ patients to assess patient-level changes. The relationship between R-wave amplitude and FP incidence was also evaluated.

Results: AI-based filtering, by AccuRhythm AI automatic analysis, reduced false pause alerts by 62% and false atrial fibrillation alerts by 33%, saving 210 clinician hours over 6 months. Patient level analysis, among 465 Reveal LINQ patients, showed FP+ patients (patients with ≥1 false-positive transmission) reduction from 55.5% to 15.1% post-AI (p<0.001), translating to 1128 hours saved. All residual false alerts occurred in patients with R-wave amplitudes <0.4 mV.

Conclusion: Use of AccuRhythm AI was associated with a significant reduction in FPs and clinician workload while preserving diagnostic accuracy. R-wave amplitude remained a key factor influencing alert specificity, emphasising the continued importance of optimal device implantation and signal quality.

Download full-text PDF

Source
http://dx.doi.org/10.1136/heartjnl-2025-326430DOI Listing

Publication Analysis

Top Keywords

reveal linq
16
implantable loop
8
artificial intelligence
8
r-wave amplitude
8
linq linq
8
linq patients
8
linq
6
alerts
5
patients
5
optimising implantable
4

Similar Publications

Background: False-positive (FP) alerts from implantable loop recorders increase clinical workload and may delay appropriate intervention. AccuRhythm AI, a cloud-based filtering algorithm, is designed to reduce these alerts in Reveal LINQ and LINQ II devices. This study assessed the algorithm's effect on FP and clinician burden reduction, with a focus on the influence of R-wave sensing amplitude.

View Article and Find Full Text PDF

Incidence of Cardiac Arrhythmias Identified by Insertable Cardiac Monitors in Patients With Symptomatic Heart Failure.

JACC Heart Fail

August 2025

Medical University of South Carolina, Charleston, South Carolina, USA; Ralph H. Johnson Department of Veterans Affairs Health Care System, Charleston, South Carolina, USA.

Background: Cardiac bradyarrhythmias and tachyarrhythmias in chronic heart failure (CHF) patients are associated with increased morbidity and mortality. Insertable cardiac monitors provide a continuous, ambulatory, accurate monitoring strategy for patients with CHF who are not candidates for cardiac implantable electronic devices.

Objectives: This study aims to assess the occurrence of cardiac arrhythmias (CAs) in patients with CHF across the ejection fraction (EF) spectrum and not indicated for cardiac implantable electronic devices.

View Article and Find Full Text PDF

Data on the cardiovascular-kidney effects and safety of empagliflozin among patients with acute myocardial infarction are limited. EMPACT-MI (Study to Evaluate the Effect of Empagliflozin on Hospitalization for Heart Failure and Mortality in Patients with Acute Myocardial Infarction) was a double-blind, multicenter clinical trial that randomized 6,522 patients with acute myocardial infarction and risk for heart failure to empagliflozin or placebo. Here we show in this secondary analysis that the mean estimated glomerular filtration rate at baseline was 76.

View Article and Find Full Text PDF

Impact of statins as immune-modulatory agents on inflammatory markers in adults with chronic diseases: A systematic review and meta-analysis.

PLoS One

May 2025

Institute of Infectious Diseases and Molecular Medicine (IDM), Department of Pathology, Division of Immunology, Faculty of Health Sciences, University of Cape Town, South Africa.

While numerous studies have extensively documented the pleiotropic effects of statins, including their capacity to reduce inflammation, there is a lack of research estimating the anti-inflammatory effectiveness of statins among individuals with chronic diseases. This meta-analysis evaluates the effect of statin therapy on inflammatory markers and the lipid profile in patients with chronic diseases by analysing evidence from randomized controlled trials (RCTs). We conducted a systematic review and searched articles published between 1st January 1999 and 31st December 2023 in databases including PubMed, Web of Science, Scopus, and Cochrane.

View Article and Find Full Text PDF

Application of insertable cardiac monitors in the real world: an observational cohort study in China.

BMC Cardiovasc Disord

April 2025

Department of Cardiology, Cardiovascular Center, Beijing Friendship Hospital, Capital Medical University, Beijing, China.

Background: Insertable cardiac monitors (ICMs) are increasingly used for long-term electrocardiographic monitoring. However, the data on ICMs remains limited in China.

Methods: In this retrospective observational study, we evaluated the real-world use and outcomes of patients consecutively receiving Reveal LINQ (Medtronic Ltd, Minneapolis, MN) devices from 2020 to 2022 at the Cardiovascular Center of Beijing Friendship Hospital.

View Article and Find Full Text PDF