Article Abstract

Download full-text PDF

Source
http://dx.doi.org/10.1177/19433654251366894DOI Listing

Publication Analysis

Top Keywords

bench evaluation
4
evaluation cpap
4
cpap devices
4
devices resource-limited
4
resource-limited environments
4
bench
1
cpap
1
devices
1
resource-limited
1
environments
1

Similar Publications

Introduction: Benchtop and animal models have traditionally been used to study the propagation of Onyx Liquid Embolic Systems (Onyx) used in the treatment of brain arteriovenous malformations (AVM). However, such models are costly, do not provide sufficient detail to elucidate how variations in Onyx viscosity alter flow dynamics, and rely on some trial-and-error, resulting in elongated timelines for product development.

Objectives: The goal of this study was to leverage Computational Fluid Dynamics (CFD) simulations to predict the behavior of different Onyx formulations.

View Article and Find Full Text PDF

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary noninvasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered.

View Article and Find Full Text PDF

BackgroundA stable guiding system is essential for successful carotid artery stenting (CAS), particularly when navigating tortuous aortic or supra-aortic anatomy. However, data on the mechanical behavior of stent delivery systems remain scarce.ObjectiveTo assess and compare the bending stiffness and trackability of five commercially available carotid stent delivery systems using bench-top experiments.

View Article and Find Full Text PDF

The development of sensors for monitoring breath acetone, a key biomarker for ketosis in diabetes mellitus, represents a critical frontier in medical diagnostics, promising a painless alternative to invasive blood tests. This review provides a comprehensive and critical evaluation of the state-of-the-art in acetone gas sensing technologies, including chemiresistive, optical, electrochemical, conductometric, and microwave platforms. We focus specifically on recent breakthroughs driven by advanced materials, analyzing how novel nanostructures from two-dimensional (2D) materials such as MXenes to porous metal-organic frameworks (MOFs) are engineered to push performance to clinically relevant parts-per-billion (ppb) sensitivity.

View Article and Find Full Text PDF

Wound management, healing, and early prosthetic rehabilitation: Part 3 - A scoping review of chemical biomarkers.

Can Prosthet Orthot J

February 2025

Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, Scotland.

Background: Poor post-amputation healing delays prosthetic fitting, adversely affecting mortality, quality of life, and cardiovascular health. Current residual limb assessments are subjective and lack standardized guidelines, emphasizing the need for objective biomarkers to improve healing and prosthesis readiness assessments.

Objectives: This review aimed to identify predictive, diagnostic, and indicative chemical biomarkers of healing of the tissues and structures found in the residual limbs of adults with amputation.