Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This work presents a machine learning (ML)-optimized dual-band wearable antenna designed specifically for biomedical applications in healthcare monitoring. Fabricated on a Rogers substrate of 40 × 41 mm, the antenna operates at 2.4 GHz and 5.8 GHz with measured bandwidths of 4.5% and 2.9%, gains of 3.8 dBi and 6.0 dBi, and high radiation efficiencies (92% and 91.7%, respectively). Bidirectional and directional radiation patterns are noted in the E-plane, while the H-plane exhibits omnidirectional patterns at the lower and upper bands. To ensure the antenna's safety for biomedical use, specific absorption rate (SAR) assessments were conducted, CST MWS simulations evaluated the SAR of the proposed wearable antenna on arm, chest, and lap placements at 5 mm distance. At 2.4 GHz, 1 g/10 g SAR values were 0.533/0.919 W/kg (arm), 0.864/1.455 W/kg (chest), and 0.892/1.122 W/kg (lap). At 5.8 GHz, results were 0.872/1.241 W/kg (arm), 0.577/1.433 W/kg (chest), and 0.428/1.341 W/kg (lap), all well within safety limits. The proposed healthcare monitoring system integrates a SEN11547 pulse sensor and an LM35 temperature sensor to measure heart rate and body temperature, transmitting the data to the ThingSpeak IoT platform via the NodeMCU ESP-32S Wi-Fi module, ensuring real-time data availability. The heart rate ranged from 65 to 99 BPM, and the body temperature ranged from 30 to 37 °C. The supervised regression ML approach was effectively utilized to predict the antenna's reflection coefficient (S). Performance evaluation of the models employed metrics such as mean absolute error (MAE), mean squared error (MSE), root mean squared logarithmic error (RMSLE), mean squared logarithmic error (MSLE), and R-squared (R). The ensemble regression model outperformed others, delivering the lowest errors (MAE: 0.83%, MSE: 1.64%, RMSLE: 0.56%, RMSE: 1.83%, MSLE: 0.44%) and the highest accuracy (R: 97.79%) while reducing the computational time by 70% compared to conventional methods. Results validate the antenna's reliability and effectiveness for wearable healthcare applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12373866PMC
http://dx.doi.org/10.1038/s41598-025-15984-9DOI Listing

Publication Analysis

Top Keywords

wearable antenna
12
dual-band wearable
8
healthcare monitoring
8
w/kg arm
8
w/kg chest
8
w/kg lap
8
heart rate
8
body temperature
8
squared logarithmic
8
logarithmic error
8

Similar Publications

This research investigates the potential of a sectoral Cylindrical Dielectric Resonator Antenna (CDRA) for biomedical telemetry. CDRAs are known for their low-loss, ruggedness, and stability, but their limited bandwidth and size make them unsuitable for wearable devices. The research addresses these limitations by proposing a dual-mode antenna that operates in [Formula: see text] and [Formula: see text] modes.

View Article and Find Full Text PDF

Recent advances of stretchable soft antennas: material, structure and integration.

Nanoscale Horiz

August 2025

State Key Laboratory of Flexible Electronics & Institute of Flexible Electronics, Northwestern Polytechnical University, Xi'an 710129, China.

Stretchable soft antennas represent a transformative class of devices that seamlessly integrate wireless communication into deformable and dynamic platforms. Enabled by advances in functional materials and structural engineering, these antennas can withstand large mechanical deformations while maintaining stable electromagnetic performance - unlocking new possibilities in wearable electronics, soft robotics, and implantable biomedical systems. This review systematically surveys recent progress in conductive material choices - from traditional metals and liquid metal to nanocomposites and hybrid architectures - and examines how structural strategies such as serpentine layouts, kirigami patterns, and out-of-plane designs redistribute strain to preserve antenna performance under repeated deformation.

View Article and Find Full Text PDF

This work presents a machine learning (ML)-optimized dual-band wearable antenna designed specifically for biomedical applications in healthcare monitoring. Fabricated on a Rogers substrate of 40 × 41 mm, the antenna operates at 2.4 GHz and 5.

View Article and Find Full Text PDF

This article focuses on the design and development of a flexible hexagonal microstrip patch antenna fabricated on a Polydimethylsiloxane (PDMS) substrate for potential use in 5G and wearable applications. The antenna geometry was selected to operate in a higher-order resonant mode to enhance performance under mechanical bending. To accelerate the design process and determine the most effective model for predicting optimal geometrical parameters that yield improved impedance matching at the target frequency, four supervised machine learning algorithms including Random Forest, XGBoost, CatBoost and LightGBM were evaluated and compared.

View Article and Find Full Text PDF

E-Textiles through a Combination of Laser-Induced Forward Transfer and Electroless Copper Deposition.

ACS Appl Mater Interfaces

August 2025

Research Institute for Textile Chemistry and Textile Physics, University of Innsbruck, Hoechsterstr. 73, Dornbirn 6850, Austria.

Electronic textiles (e-textiles) offer promising capabilities in communication, energy storage, safety, comfort, and sensing. A key requirement for e-textiles is the development of conductive patterns with high design flexibility, high electrical conductivity, and strong adhesion to the textile substrates. In this study, a simple approach combining laser-induced forward transfer (LIFT) and electroless copper (Cu) deposition to create high-resolution, highly conductive patterns on textiles is presented.

View Article and Find Full Text PDF