Article Abstract

Conscious telemetry-instrumented dogs are used during cardiovascular safety assessment in early drug development for the collection of cardiovascular function parameters such as electrocardiography (ECG), heart rate, mean arterial pressure, and cardiac contractility. To refine the use of animals for exploratory toxicology studies, these dogs may be repurposed into these studies following failure of their implanted device. Telemetry instrumentation involves surgical placement of a pressure catheter through the left ventricular apex of the heart. Slight variations in placement and extension of the catheter tip into the ventricular chamber lead to variability in cardiac pathology associated with the instrumentation. Reuse of these animals in toxicologic assessments therefore requires the pathologist to be aware of the spectrum of histologic changes that may occur because of telemetry instrumentation. This report describes cardiac findings in 12 telemetry-instrumented male dogs with implant duration ranging from 7 to 37 months and discusses considerations and recommendations for use of these animals.

Download full-text PDF

Source
http://dx.doi.org/10.1177/01926233251364231DOI Listing

Publication Analysis

Top Keywords

telemetry instrumentation
12
histopathologic findings
4
findings heart
4
heart associated
4
associated telemetry
4
instrumentation
4
instrumentation beagle
4
dogs
4
beagle dogs
4
dogs conscious
4

Similar Publications

Telemetry devices are essential for preclinical cardiovascular research, allowing for continuous monitoring of physiological parameters like electrocardiogram, temperature, and respiration in experimental animals without causing disruption. Traditional methods, such as intra-abdominal placement, can cause discomfort, particularly in pigs due to their habit of lying prone. To address this issue, a novel surgical technique was developed for implanting wireless telemetry devices in pigs, aimed at improving animal comfort and maintaining signal quality.

View Article and Find Full Text PDF

Introduction: Accurate evaluation of respiratory rate and pattern is important in health and disease; however, it can be challenging in children and babies due to small size and poor tolerability of existing monitoring equipment. This protocol outlines a study evaluating the feasibility of collecting respiratory data using a chest-worn accelerometer-based motion sensor in paediatric patients at risk of apnoea, respiratory failure and sudden death.

Methods And Analysis: This is an observational feasibility study over a 2-year period.

View Article and Find Full Text PDF

Introduction: Cardiac rehabilitation (CR) improves the outcomes of patients with chronic heart disease. However, participation in hospital-based programs is limited, partly because of accessibility issues. Notably, most CRs are performed unsupervised at home, making it challenging for healthcare providers and patients to monitor progress accurately or provide tailored feedback.

View Article and Find Full Text PDF

Conscious telemetry-instrumented dogs are used during cardiovascular safety assessment in early drug development for the collection of cardiovascular function parameters such as electrocardiography (ECG), heart rate, mean arterial pressure, and cardiac contractility. To refine the use of animals for exploratory toxicology studies, these dogs may be repurposed into these studies following failure of their implanted device. Telemetry instrumentation involves surgical placement of a pressure catheter through the left ventricular apex of the heart.

View Article and Find Full Text PDF

Processing the optimal length of electrode arrays for cochlear implants (CIs) is vital for achieving maximum effectiveness, and the results tend to differ between the preoperative radiological estimations and the depth reached at the time of surgery. This study evaluates the feasibility of using a flexible insertion test electrode with colored depth markers to determine the practically achievable electrode insertion depth before CI electrode array placement. The study was conducted at a tertiary center and included patients with inner ear anomalies, reimplantation cases, and profound deafness with no residual hearing.

View Article and Find Full Text PDF