98%
921
2 minutes
20
While markerless motion capture system has recently gained interest, little is known on the accuracy of Theia 3D for measuring shoulder kinematics. This study aimed to compare shoulder kinematics across the full range of arm motion between Theia 3D and a gold standard marker-based motion capture system. Shoulder kinematics of 20 healthy subjects were measured during three repetitions of bilateral full arm scaption, abduction, flexion, internal rotation, external rotation, and internal and external rotation at 90° abduction. Data were simultaneously collected with Theia 3D (v2024.1.24) markerless and marker-based motion capture. Markerless and marker-based angular trajectories had similar patterns, with larger differences towards the inflection point of the movements and with the markerless trajectories having mostly greater values than marker-based trajectories. Root mean square differences were smallest for abduction angles (<6°) and largest for the external rotation angles (15.3°-22.3°). Coefficients of multiple correlations (CMCs) were mostly good to excellent (>0.75), but CMC was moderate (0.65-0.75) for flexion angles during rotation at 90° and weak (<0.65) for flexion angles during external rotation. For almost all tasks, the ranges of motion differed significantly between the two measurement systems in all three planes. However, mean differences in the coronal plane and in the sagittal plane were within the minimal clinically important differences. We found moderate to very strong correlations between the range of motion parameters of the two measurement methods. The assessment of shoulder kinematics with Theia 3D is promising but further improvements are needed for clinical routine application.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2025.112905 | DOI Listing |
BMC Neurol
September 2025
Department of Neurology, University Hospital Schleswig-Holstein, Kiel, Germany.
Background: Parkinson's disease (PD) is characterized by motor symptoms altering gait domains such as slow walking speed, reduced step and stride length, and increased double support time. Gait disturbances occur in the early, mild to moderate, and advanced stages of the disease in both backward walking (BW) and forward walking (FW), but are more pronounced in BW. At this point, however, no information is available about BW performance and disease stages specified using the Hoehn and Yahr (H&Y) scale.
View Article and Find Full Text PDFGait Posture
September 2025
Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand.
Background: While the plantar fat pad is known for its role in shock absorption and plantar force distribution during weight-bearing activities, its impact on running biomechanics is not well understood.
Research Question: Does plantar fat pad thickness affect lower limb biomechanics and plantar pressure distribution during running in healthy adults?
Methods: This cross-sectional observational study involved fourteen participants (18-50 years) who ran at their preferred speed on a 10-meter walkway while lower limb kinematics and ground reaction forces were recorded using a motion capture system. Plantar pressure and force on the right foot were measured using a pressure platform.
PLoS One
September 2025
China Institute of Sport Science, General Administration of Sport of China, Beijing, China.
Background: Golf is a sophisticated sport that integrates precision, skillfulness, and strategic thinking, with swing techniques of different clubs exhibiting distinct biomechanical characteristics. This study aims to investigate the biomechanical characteristics of golfers' full swings with different clubs from kinematic and dynamics perspectives, thereby providing insights for optimizing full swing techniques.
Methods: Ten low-handicap right-handed college male golfers were recruited, and their full swing parameters with the driver, 5-iron, and 7-iron (each club was successfully collected 10 times) were synchronously collected using a 250 Hz infrared motion capture system and a 1000 Hz three-dimensional force platform.
PLoS One
September 2025
School of Health & Society, University of Salford, Salford, Greater Manchester, United Kingdom.
Background: Velocity-Based Training (VBT) is an emerging method in resistance training for objectively prescribing and monitoring training intensity and neuromuscular function. Given its growing popularity, assessing the validity and reliability of VBT devices is critical for strength and conditioning coaches.
Objective: The primary purpose of this review was twofold: (1) to identify and address methodological gaps in current assessments of VBT device validity and reliability, and (2) to propose and apply a novel, multi-layered, criterion-based framework-developed in collaboration with statisticians and domain experts-for evaluating these devices.
J Chem Phys
September 2025
Department of Chemistry, University of Rochester, Rochester, New York 14627, USA.
We introduce an efficient method, TTN-HEOM, for exactly calculating the open quantum dynamics for driven quantum systems interacting with highly structured bosonic baths by combining the tree tensor network (TTN) decomposition scheme with the bexcitonic generalization of the numerically exact hierarchical equations of motion (HEOM). The method yields a series of quantum master equations for all core tensors in the TTN that efficiently and accurately capture the open quantum dynamics for non-Markovian environments to all orders in the system-bath interaction. These master equations are constructed based on the time-dependent Dirac-Frenkel variational principle, which isolates the optimal dynamics for the core tensors given the TTN ansatz.
View Article and Find Full Text PDF