98%
921
2 minutes
20
Recently novel types of imaging spectrometers have been successfully demonstrated, where photonic crystals filters are placed onto a detector. For focused beams, it is however unclear how numerical aperture (NA), aperture shape and aberrations affect the transmission of these filters and there is currently no established and computational efficient method to assess this. In this work we present an angular spectrum method to reconstitute focused beam fields and transmissions based on plane wave simulations. Once these plane wave simulations have been performed, the transmission of arbitrary pupils, aberrations and NA can be directly computed. We investigate the accuracy of this method by comparing the synthesized transmission and Poynting vectors with a fully simulated focused Gaussian beam. These results show that an angular sampling between 0.5° and 0.8° is required to achieve an accurate result depending on the mesh sampling of the simulation. Lastly, we demonstrate how this method can be used to investigate the effect of the pupil shape and aberrations on the transmission profiles. This analysis enables the identification of spectral regions which are sensitive to the instrument design but also regions which appear robust. We believe that the method described in this work can provide scientists and optical engineers a tool to perform detailed performance studies on these promising new instruments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.553298 | DOI Listing |
Adv Radiat Oncol
October 2025
Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiation Oncology and Radiotherapy, Augustenburger Platz 1, 13353 Berlin, Germany.
Purpose: To evaluate the impact of an optimized online adaptive radiation therapy workflow on physician involvement.
Methods And Materials: Data from a prospective phase 2 trial involving 34 prostate cancer patients treated with cone beam computed tomography (CBCT)-based online adaptive radiation therapy (62 Gy in 20 fractions) were analyzed. Manual interventions were required for 2 steps in the workflow: radiation therapy technologist review and adjustment of automatically segmented organs, guiding target segmentation, so-called "influencer," while physicians reviewed and refined the targets.
Beilstein J Nanotechnol
September 2025
B. I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, 220072 Minsk, Belarus.
In this study, silicon nanoparticles (NPs) were produced by pulsed laser ablation in a liquid, aiming to investigate the influence of a laser beam profile on the properties of the resultant NPs. Morphology, inner structure, and phase composition of the formed NPs were characterized by means of ultraviolet-visible spectroscopy, high-resolution transmission electron microscopy, and Raman and photoluminescence spectroscopies, and the correlation of the NP properties with the laser beam profile was studied. Three different beam profiles were selected, namely, a Bessel beam produced using an axicon, an annular profile formed using a combination of an axicon and a converging lens, and a Gaussian beam focused on the surface of a Si target using the same converging lens.
View Article and Find Full Text PDFFront Vet Sci
August 2025
Fish Research Centre, Faculty of Environmental Agricultural Sciences, Arish University, El Arish, Egypt.
The well-known technique of microtomy, which is an essential cutting tool, was first developed for light and transmission electron microscope uses, but it is currently also utilized to prepare specimens for atomic force microscopy (AFM), ion microscopy using a focused ion beam (FIB), and scanning electron microscopy (SEM). Ultramicrotomy can only be used on soft substances and metals that are sufficiently ductile to be cut with a diamond knife. Before being sliced by a microtome, many soft materials must first go through numerous preparatory processes.
View Article and Find Full Text PDFMed Phys
September 2025
Image X Institute, Faculty of Medicine and Health, University of Sydney, Eveleigh, New South Wales, Australia.
Introduction: Prospective hazard analysis (PHA) was introduced to the wider medical physics community by the initiation of American association of physicists in medicine task group 100 in 2003. Since then, there has been increasing interest in the applicability of PHA to radiotherapy for the purpose of keeping patients safe and assessing the risks within the whole practice of radiotherapy. The purpose of this research was to review the PHA literature focusing on which techniques and technologies have been assessed, how they have been assessed, and what can be learnt.
View Article and Find Full Text PDFMicrosyst Nanoeng
September 2025
Center for Terahertz Waves, College of Precision Instrument and Optoelectronics Engineering, and the Key Laboratory of Optoelectronics Information and Technology (Ministry of Education), Tianjin University, Tianjin, 300072, China.
Terahertz communication systems demand versatile devices capable of simultaneously controlling propagating waves and surface plasmon polaritons (SPPs) in far-field (FF) and near-field (NF) channels, yet existing solutions are constrained by volatile operation, single-function limitations, and the inability to integrate NF and FF functionalities. Here, we present a nonvolatile reconfigurable terahertz metasurface platform leveraging the phase-change material GeSbTe(GST) to achieve on-demand dual-channel modulation-a first in the terahertz regime. By exploiting the stark conductivity contrast of GST between amorphous and crystalline states, our design enables energy-efficient switching between NF-SPP manipulation and FF-wavefront engineering without requiring continuous power input.
View Article and Find Full Text PDF