Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Two selective methods were developed for detecting mercury ions (Hg⁺) in food and water samples using catalytic fluorometry based on Au-Hg amalgamation with enhanced peroxidase-like activity. These approaches include (i) a laser-printed microfluidic paper-based analytical device (LP-µPAD) and (ii) a paper-based microcentrifuge tube test kit. The LP-µPAD was fabricated via commercial laser printing and integrated gold nanoparticles (AuNPs) with o-phenylenediamine (OPD) and hydrogen peroxide (H₂O₂). The test kit enabled Hg⁺ detection in food by reducing Hg⁺ to Hg⁰ with stannous chloride, facilitating Au-Hg amalgam formation in the detection zone. Both approaches utilized the Au-Hg amalgam to catalyze H₂O₂-mediated oxidation of OPD, generating fluorescent 2,3-diaminophenazine (DAP), further enhancing fluorescence intensity in proportion to Hg⁺ concentrations. The LP-µPAD exhibited a detection range of 3.0-20.0 µg L⁻ with a limit of detection (LOD) of 1.65 µg L⁻, whereas the test kit provided a detection range of 0.1-1.0 mg L⁻ with an LOD of 0.08 mg L⁻. Both sensors showed high selectivity for Hg⁺ over other ions and performed well in real sample analyses, aligning closely with results from conventional methods.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-025-07412-6DOI Listing

Publication Analysis

Top Keywords

test kit
16
catalytic fluorometry
8
au-hg amalgamation
8
microcentrifuge tube
8
tube test
8
au-hg amalgam
8
detection range
8
hg⁺
5
detection
5
approaches mercury
4

Similar Publications

Cervical cancer remains the leading cause of cancer death among women in sub-Saharan Africa and is more severe in high HIV-burdened countries due to persistent high-risk human papillomavirus (hrHPV). In 2021, the World Health Organization recommended primary hrHPV testing for cervical cancer screening; however, optimal triage strategies following positive hrHPV tests remain unclear. We conducted a prospective cost analysis of triage methods for positive hrHPV results among women living with and without HIV in Gaborone, Botswana.

View Article and Find Full Text PDF

Astrocytes play a crucial role in ensuring neuronal survival and function. In stroke, astrocytes trigger the unfolded protein response (UPR) to restore endoplasmic reticulum homeostasis. Mesencephalic astrocyte-derived neurotrophic factor (MANF), a newly identified endoplasmic reticulum stress-induced neurotrophic factor, attenuates cerebral ischemic injury by reducing inflammatory responses.

View Article and Find Full Text PDF

Background: Anti-integrin αvβ6 IgG autoantibodies showed good sensitivity and optimal specificity in ulcerative colitis (UC) compared to controls. We aim at confirming the diagnostic accuracy of anti-integrin αvβ6 autoantibodies in an Italian multicentric cohort.

Methods: This observational multicentric study included adult and pediatric patients with inflammatory bowel disease and controls.

View Article and Find Full Text PDF

Whole exome sequencing (WES) is a well-established tool for clinical diagnostics, is more cost-effective and faster to analyse than whole genome sequencing and has been implemented to uplift diagnostic rates in human disease. However, challenges remain to achieve comprehensive and uniform coverage of targets, and high sensitivity and specificity. Differences in genomic target regions and exome capture mechanism between kits may lead to differences in overall coverage uniformity and capture efficiency.

View Article and Find Full Text PDF

Performance of the ELITe InGenius system for hepatitis B virus DNA quantification.

Diagn Microbiol Infect Dis

September 2025

French National Reference Center for Hepatitis B, C and delta Viruses, Department of Virology, Hôpital Henri Mondor, Créteil, France; INSERM U955, Créteil, France. Electronic address:

Measurement of hepatitis B virus (HBV) DNA levels is the standard of care for diagnosis active HBV infection, assessing disease severity and prognosis, and guiding treatment decisions and monitoring response to therapy. In the study, the analytical and clinical performance of the ELITe InGenius System for quantifying HBV DNA was evaluated. A total of 377 of archived EDTA plasma or serum specimens were tested.

View Article and Find Full Text PDF