Article Abstract

MXene-based smart contact lenses demonstrate a cutting-edge advancement in wearable ophthalmic technology, combining real-time biosensing, therapeutic capabilities, and user comfort in a single platform. These devices take the advantage of the exceptional electrical conductivity, mechanical flexibility, and biocompatibility of two-dimensional MXenes to enable noninvasive, tear-based monitoring of key physiological markers such as intraocular pressure and glucose levels. Recent developments focus on the integration of transparent MXene films into the conventional lens materials, allowing multifunctional performance including photothermal therapy, antimicrobial and anti-inflammation protection, and dehydration resistance. These innovations offer promising strategies for ocular disease management and eye protection. In addition to their multifunctionality, improvements in MXene synthesis and device engineering have enhanced the stability, transparency, and wearability of these lenses. Despite these advances, challenges remain in long-term biostability, scalable production, and integration with wireless communication systems. This review summarizes the current progress, key challenges, and future directions of MXene-based smart contact lenses, highlighting their transformative potential in next-generation digital healthcare and ophthalmic care.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12325838PMC
http://dx.doi.org/10.1007/s40820-025-01863-5DOI Listing

Publication Analysis

Top Keywords

contact lenses
12
mxene-based smart
8
smart contact
8
mxene-based wearable
4
wearable contact
4
lenses
4
lenses integrating
4
integrating smart
4
smart technology
4
technology vision
4

Similar Publications

Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).

Methods: Case report and literature review.

Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.

View Article and Find Full Text PDF

A Clinical Evaluation of Lifitegrast Ophthalmic Solution 5% in Symptomatic Contact Lens Wearers.

Clin Ophthalmol

August 2025

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.

Purpose: To evaluate the effectiveness of lifitegrast ophthalmic solution 5% in alleviating end-of-day dryness and discomfort in symptomatic contact lens (CL) wearers.

Patients And Methods: This was an open-label study in symptomatic CL wearers with ratings of ≥40 for end-of-day dryness on a visual analog scale (VAS; 0-100 scale; 100 worst). Participants wore their habitual CLs and instilled lifitegrast twice daily for 12 weeks with lenses removed.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.

Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.

View Article and Find Full Text PDF

Baseline ocular biometrics in children with orthokeratology-induced axial length reduction or elongation.

BMC Ophthalmol

September 2025

Optometry Center, Shaanxi Key Laboratory of Ophthalmology, Xi'an No.1 Hospital (the First Affiliated Hospital of Northwest University), Shaanxi Institute of Ophthalmology, No.30, Fenxiang Alley, South Street, Xi'an, Shaanxi Province, 710002, China.

Purpose: To determine the baseline ocular biometrics in children with axial length reduction after orthokeratology for better myopia control.

Methods: Changes in ocular parameters in 164 subjects who completed one year of Ortho-K treatment were retrospectively reviewed. The subjects were divided into AL reduction (n = 105, ≤ 0 mm/year axial growth) and AL elongation (n = 59, ≥ 0.

View Article and Find Full Text PDF

Introduction: This review aims to analyse the application of the measure methods and measure contents of the outcomes reported in studies on slowing myopia, and the associations between outcomes and study characteristics.

Methods: Publications were identified by a search of seven electronic databases including China National Knowledge Infrastructure, China Biology Medicine, Wanfang database, CQVIP database, PubMed, Cochrane Library and Excerpta Medica Database, for relevant terms like myopia and randomized controlled trial from construction to Sept. 15th, 2023.

View Article and Find Full Text PDF