Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The aim of this study was to establish a simple, sensitive, and robust ultra-high performance liquid chromatography coupled with fluorescence detection method (UPLC-FLD) for the determination of chiral D/L-serine in cells. D/L-serine in cells were derivatizated by o-phthalaldehyde (OPA) and N-acetyl-L-cysteine (NAC). Carbocisteine was selected as the internal standard. The derivatives were separated on a C18 column by gradient elution. The excitation and emission wavelengths for fluorescence determination are 340 nm and 450 nm, respectively. The retention time of D-serine and L-serine was 23.3 and 23.9 min respectively, which presented a perfect separation. The accuracy of D-serine and L-serine were ranged from 96.46 % to 109.63 % and 95.50 %-102.20 %, respectively. The precision of D-serine and L-serine were ranged from 4.34 % to 14.56 % and 3.56 %-13.73 %. The limit of quantitation of D-serine and L-serine were 0.1 nmol/mL. The concentration of D/L-serine varies in different cell lines. This method can satisfy the determination of D/L-serine in astrocytes and other cells, which can be used for the study of D/L-serine metabolism and related mechanisms. In short, we have established a simple, stable, reliable and robust method for the determination of D/L-serine in cells. In addition, the D/L-serine levels in different cells were quantified in this study, which can provide a reference for the study of D/L-serine metabolism in cells.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2025.128634DOI Listing

Publication Analysis

Top Keywords

d/l-serine cells
16
d-serine l-serine
16
d/l-serine
9
ultra-high performance
8
performance liquid
8
l-serine ranged
8
determination d/l-serine
8
study d/l-serine
8
d/l-serine metabolism
8
cells
7

Similar Publications

The aim of this study was to establish a simple, sensitive, and robust ultra-high performance liquid chromatography coupled with fluorescence detection method (UPLC-FLD) for the determination of chiral D/L-serine in cells. D/L-serine in cells were derivatizated by o-phthalaldehyde (OPA) and N-acetyl-L-cysteine (NAC). Carbocisteine was selected as the internal standard.

View Article and Find Full Text PDF

The role of astrocytes in depression, its prevention, and treatment by targeting astroglial gliotransmitter release.

Proc Natl Acad Sci U S A

November 2024

Laboratorio de Neurobiología, Instituto de Ciencias Biomédicas, Facultad de Medicina, Universidad Andres Bello, Santiago 8370146, Chile.

The role of ventral hippocampus (vHipp) astroglial gliotransmission in depression was studied using chronic restraint stress (CRS) and chronic unpredictable mild stress (CUMS) rodent models. CRS increased Cx43 hemichannel activity and extracellular glutamate levels in the vHipp and blocking astroglial Cx43 hemichannel-dependent gliotransmission during CRS prevented the development of depression and glutamate buildup. Moreover, the acute blockade of Cx43 hemichannels induced antidepressant effects in rats previously subjected to CRS or CUMS.

View Article and Find Full Text PDF

The influence of modified molecular (D/L-serine) chirality on the theragnostics of PAMAM-based nanomedicine for acute kidney injury.

J Mater Chem B

November 2021

College of Chemistry and Materials Science, Jiangsu Key Laboratory of Bio-functional Materials, Jiangsu Collaborative Innovation Centre of Biomedical Functional Materials, Nanjing Normal University, Nanjing, 210023, China.

Acute kidney injury (AKI) is a severe clinical disease with extremely high morbidity and mortality. It is challenging to find a simple method for early detection of AKI and monitoring the treatment results. Renal tubular damage and inflammation are early events in AKI.

View Article and Find Full Text PDF

Nonionic and Water-Soluble Poly(d/l-serine) as a Promising Biomedical Polymer for Cryopreservation.

ACS Appl Mater Interfaces

April 2021

Key Laboratory of Advanced Materials (MOE), Department of Chemical Engineering, Tsinghua University, Beijing 100084, China.

Water-soluble, biodegradable, nonionic, and biocompatible polymers with multiple functional groups are highly desired for biomedical applications. Here, we report that water-soluble nonionic poly(d/l-serine) is chirality-controllable, biodegradation-controllable, and non-cytotoxic. Hence, it can be a highly sought-after alternative to the widely used poly(ethylene glycol), with an additional advantage of having multiple hydroxyl groups for further functionalization.

View Article and Find Full Text PDF

Isotope labels are frequently used tools to track metabolites through complex biochemical pathways and to discern the mechanisms of enzyme-catalyzed reactions. Isotopically labeled l-serine is often used to monitor the activity of the first enzyme in sphingolipid biosynthesis, serine palmitoyltransferase (SPT), as well as labeling downstream cellular metabolites. Intrigued by the effect that isotope labels may be having on SPT catalysis, we characterized the impact of different l-serine isotopologues on the catalytic activity of recombinant SPT isozymes from humans and the bacterium Our data show that SPT activity displays a clear isotope effect with [2,3,3-D]l-serine, whereas the human SPT isoform does not.

View Article and Find Full Text PDF