Article Abstract

Background: Patient-specific instrumentation (PSI) was developed to improve accuracy and efficiency in implant placement for total ankle arthroplasty (TAA). This study represents the first to measure the accuracy of PSI regarding implant alignment and implant size in the INBONE II total ankle system (Stryker). A secondary goal was to compare radiographic and clinical outcomes between the PSI and that of a matched group of implants performed with standard instrumentation.

Methods: This retrospective study of 92 patients (46 PSI and 46 non-PSI cases matched by age and sex) was performed at a single institution between 2006 and 2024, including TAA patients with INBONE II implants. Median age was 61 years (range 27-81). Median body mass index (BMI) was 29.6 (range 19.9-45.6). One surgeon performed 71% of PSI. A different surgeon performed 96% of non-PSI cases. PSI alignment (tibiotalar angle [TTA]), deformity correction (talar-tilt [TT]), radiation exposure, tourniquet, and operative time were compared to the standard jig method (non-PSI). Total fluoroscopy, tourniquet and procedure time, and preoperative and postoperative radiographs were analyzed.

Results: PSI predicted the correct size in 67% (n = 31) of talus implants and 89% (n = 41) of tibial implants. Median absolute deviation in the mortise view was 1.3 (IQR 0.53-2.18) and 1.8 (IQR 1.35-3.5) in the lateral view. For both groups, postoperative median TTA deviation was less than 2 degrees and postoperative median TT was less than or equal to 1 degree. Median fluoroscopic time was 92.1 seconds for PSI and 104.3 seconds for non-PSI. PSI had a longer tourniquet (156.5 vs 134.5 minutes) and procedure time (188 vs 161 minutes) compared with non-PSI.

Conclusion: In this study of stemmed TAA implants, surgeons achieved alignment generally consistent with PSI predictions. PSI adequately predicted implant size. For most cases, PSI achieved similar alignment and correction of deformity compared with standard instrumentation. PSI did not improve radiographic alignment compared with traditional instrumentation and was associated with longer operative times, possibly reflecting the primary surgeon's early experience with the technique. Each surgeon should select PSI or the standard jig based on their experience and preference.

Download full-text PDF

Source
http://dx.doi.org/10.1177/10711007251353787DOI Listing

Publication Analysis

Top Keywords

psi
14
total ankle
12
patient-specific instrumentation
8
alignment compared
8
inbone total
8
ankle arthroplasty
8
instrumentation psi
8
implant size
8
non-psi cases
8
implants median
8

Similar Publications

Taxonomy of paradigms for neuropsychological assessment of body representation based on a critical review.

Neurologia (Engl Ed)

September 2025

Facultad de Psicología, Universidad Complutense de Madrid, Campus de Somosaguas 28223 - Pozuelo de Alarcón, Madrid, Spain. Electronic address:

Introduction: The concept of body representation overlaps with others, such as body schema, body image, body semantics, structural description, body description or body map. A taxonomy is proposed that classifies body schema, body structural description and body semantics. The aim of this narrative review is to analyze the supply of instruments for neuropsychological assessment of body representation and to propose a classification of their paradigms.

View Article and Find Full Text PDF

Occipital Monitoring of PSI During Frontal Tumor Resection: A Feasibility Study.

World Neurosurg

September 2025

Department of Anesthesiology, Xuanwu Hospital, Capital Medical University, Beijing, China. Electronic address:

Background: Frontal patient state index (PSI) monitoring is impractical during frontal lobe tumor resection due to surgical field interference. No validated alternative monitoring positions exist currently. This study evaluated the agreement between standard frontal and experimental occipital PSI monitoring.

View Article and Find Full Text PDF

Dynamic control of electron correlations in photodoped charge-transfer insulators.

Sci Adv

September 2025

Laboratory of Ultrafast Spectroscopy, SB-ISIC, and Lausanne Centre for Ultrafast Science (LACUS), Ecole Polytechnique Fédérale de Lausanne, Station 6, CH-1015 Lausanne, Switzerland.

The electronic properties of correlated insulators are governed by the strength of Coulomb interactions, enabling the control of electronic conductivity with external stimuli. This work highlights that the strength of electronic correlations in nickel oxide (NiO), a prototypical charge-transfer insulator, can be coherently reduced by tuning the intensity of an optical pulse excitation. This weakening of correlations persists for hundreds of picoseconds and exhibits a recovery time independent of photodoping density across two orders of magnitude.

View Article and Find Full Text PDF

The rice cation/calcium exchanger OsCCX2 is involved in calcium signal clearance and osmotic tolerance.

J Integr Plant Biol

September 2025

Hunan Province Key Laboratory of Crop Sterile Germplasm Resource Innovation and Application, College of Life Science, Hunan Normal University, Changsha, 410081, China.

Hyperosmolality-triggered physiological drought hinders plant growth and development, leading to a drop in crop yields. Hyperosmolality triggers calcium signaling, and yet how osmotic-induced calcium signaling participates in cellular osmotic response remains enigmatic. To date, several Ca channels and transporters have been identified to regulate osmotic-induced calcium signal generation (CaSG) or Ca homeostasis.

View Article and Find Full Text PDF

Purpose: Performing a one-stage periarticular osteotomy in conjunction with total knee arthroplasty (TKA) constitutes a technically complex procedure. In such demanding cases, a personalized approach utilizing patient-specific instrumentation (PSI) may serve as an advantageous option to achieve optimal precision in bone cuts, thereby enhancing both clinical and radiological postoperative outcomes.

Methods: We present a case report of a 22-year-old man with multiple epiphyseal dysplasia (MED) resulting in knee osteoarthritis with complex femoral deformity and restricted (passive at 30-120° and active at 80-120°) range of movement (ROM).

View Article and Find Full Text PDF