Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Clinical evaluation of Artificial Intelligence (AI)-based Precise Image (PI) algorithm in brain imaging remains limited. PI is a deep-learning reconstruction (DLR) technique that reduces image noise while maintaining a familiar Filtered Back Projection (FBP)-like appearance at low doses. This study aims to compare PI, Iterative Reconstruction (IR), and FBP-in improving image quality and enhancing lesion detection in 1.0 mm thin-slice brain computed tomography (CT) images.

Methods: A retrospective analysis was conducted on brain non-contrast CT scans from August to September 2024 at our institution. Each scan was reconstructed using four methods: routine 5.0 mm FBP (Group A), thin-slice 1.0 mm FBP (Group B), thin-slice 1.0 mm IR (Group C), and thin-slice 1.0 mm PI (Group D). Subjective image quality was assessed by two radiologists using a 4- or 5‑point Likert scale. Objective metrics included contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and image noise across designated regions of interest (ROIs).

Results: 60 patients (65.47 years ± 18.40; 29 males and 31 females) were included. Among these, 39 patients had lesions, primarily low-density lacunar infarcts. Thin-slice PI images demonstrated the lowest image noise and artifacts, alongside the highest CNR and SNR values (p < 0.001) compared to Groups A, B, and C. Subjective assessments revealed that both PI and IR provided significantly improved image quality over routine FBP (p < 0.05). Specifically, Group D (PI) achieved superior lesion conspicuity and diagnostic confidence, with a 100% detection rate for lacunar lesions, outperforming Groups B and A.

Conclusions: PI reconstruction significantly enhances image quality and lesion detectability in thin-slice brain CT scans compared to IR and FBP, suggesting its potential as a new clinical standard.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00062-025-01542-3DOI Listing

Publication Analysis

Top Keywords

image quality
12
image noise
12
thin-slice brain
8
lesion detection
8
thin-slice 10 mm
8
image
7
thin-slice
6
brain image
4
quality lesion
4
detection evaluation
4

Similar Publications

The aim of the study was to evaluate the toxic metals (TMs) pollution, bioaccumulation and its potential health risk via consumption of different vegetables irrigated by different water sources released from industrial estates of Khyber Pakhtunkhwa. Water (fresh and waste), soil and vegetables samples were collected in triplicates and acid digested. Digestion of samples were followed by evaporation and filtration and then assessed for TMs via atomic absorption spectrophotometer.

View Article and Find Full Text PDF

Myocarditis is an inflammation of heart tissue. Cardiovascular magnetic resonance imaging (CMR) has emerged as an important non-invasive imaging tool for diagnosing myocarditis, however, interpretation remains a challenge for novice physicians. Advancements in machine learning (ML) models have further improved diagnostic accuracy, demonstrating good performance.

View Article and Find Full Text PDF

[The TAVI heart team].

Herz

September 2025

Department of Cardiology, Heart Center Leipzig, University of Leipzig, Strümpellstraße 39, 04289, Leipzig, Deutschland.

Since the earliest studies on transcatheter aortic valve implantation (TAVI), the heart team concept has been an integral component of treatment planning for patients with aortic valve stenosis (AS). The primary objective is to ensure patient-specific, guideline-based treatment through the structured involvement of all relevant medical disciplines. The TAVI heart team is strongly recommended with a class I indication in both European and US clinical guidelines.

View Article and Find Full Text PDF

Diagnostic tips for multi-phase post-mortem computed tomography angiography interpretation in upper gastro-intestinal bleeding.

Int J Legal Med

September 2025

University Center of Legal Medicine Lausanne-Geneva, University of Geneva, Geneva University Hospitals, Rue Michel-Servet 1, 1211, Geneva 4, Switzerland.

In the past 10 years, the Multi-phase Post-mortem Computed Tomography Angiography (MPMCTA) has considerably improved the quality and precision of postmortem diagnoses, particularly in cases with vascular implication. MPMCTA is known to have higher sensitivity for detecting the source of a hemorrhage than autopsy. Death by upper gastro-intestinal (GI) bleeding is not so uncommon in forensic practice.

View Article and Find Full Text PDF

Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.

Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.

View Article and Find Full Text PDF