The Ocular Parameter Changes Caused by Reading With Remote Image Optical Screen.

Transl Vis Sci Technol

Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study aimed to analyze the differences in ocular parameter changes induced by reading with traditional electronic screens (TESs) compared with those associated with the remote image optical screen (RIOS), further evaluating the effects of RIOS on ocular parameters.

Methods: Thirty-five healthy participants (70 eyes) were enrolled in the prospective self-controlled study, completing two distinct reading tasks. Task A: near reading using TESs for 20 minutes; and task B: near reading with RIOS for an equivalent duration. The spherical equivalent (SE), anterior segment parameters, choroidal thickness (ChT), and choroidal vascular volume (CVV) were measured both before and after each reading task.

Results: Following reading with TESs, significant myopic shifts were observed in the SE (P = 0.024), and there was a notable decrease in both anterior chamber depth and width (all P < 0.001). The lens thickness and vitreous chamber depth increased significantly (all P < 0.05). In the meantime, the ChT and CVV decreased significantly (P = 0.029 and P = 0.013, respectively), particularly beyond a region measuring 9 × 9 mm2 centered on the fovea (all P < 0.05). After reading with RIOS, no significant changes were detected in SE or any other ocular parameters, including ChT and CVV (all P > 0.05).

Conclusions: Reading with RIOS effectively alleviates myopic shift, ocular anterior segment changes, and choroidal thinning caused by traditional near work.

Translational Relevance: The study demonstrates that reading with RIOS can alleviate the ocular anterior segment changes and choroidal thinning caused by TESs. The RIOS may represent a promising strategy for myopic control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12302051PMC
http://dx.doi.org/10.1167/tvst.14.7.12DOI Listing

Publication Analysis

Top Keywords

reading rios
16
anterior segment
12
reading
10
ocular parameter
8
parameter changes
8
remote image
8
image optical
8
optical screen
8
task reading
8
reading tess
8

Similar Publications

The Ocular Parameter Changes Caused by Reading With Remote Image Optical Screen.

Transl Vis Sci Technol

July 2025

Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing, China.

Purpose: This study aimed to analyze the differences in ocular parameter changes induced by reading with traditional electronic screens (TESs) compared with those associated with the remote image optical screen (RIOS), further evaluating the effects of RIOS on ocular parameters.

Methods: Thirty-five healthy participants (70 eyes) were enrolled in the prospective self-controlled study, completing two distinct reading tasks. Task A: near reading using TESs for 20 minutes; and task B: near reading with RIOS for an equivalent duration.

View Article and Find Full Text PDF

Objective: To describe the relationship, through a scoping review, between thrombin generation assay (TGA) parameters and venous thromboembolism (VTE).

Material And Methods: A systematic search was carried out in the PubMed/MEDLINE, Embase, Cochrane, Virtual Health Library, Web of Science, and Scopus databases using descriptors for VTE and thrombin generation. Human studies assessing the association between TGA parameters and the occurrence of VTE were included.

View Article and Find Full Text PDF

Background: Myopia is a prevalent disease influenced by both genetic and environmental factors. This study aims to explore myopia risk factors, including the association between night-time reading habits under low illumination in children.

Methods: A cross-sectional survey was conducted in Argentina as part of the "Myopia Awareness Campaign" in June 2024.

View Article and Find Full Text PDF

Acoustic Characteristics of Voice and Speech in Post-COVID-19.

Healthcare (Basel)

January 2025

Department of Computer Science, Institute of Mathematics and Statistics, University of São Paulo (USP), São Paulo 05508-220, SP, Brazil.

Background/objectives: The aim of this paper was to compare voice and speech characteristics between post-COVID-19 and control subjects. The hypothesis was that acoustic parameters of voice and speech may differentiate subjects infected by COVID-19 from control subjects. Additionally, we expected to observe the persistence of symptoms in women.

View Article and Find Full Text PDF