98%
921
2 minutes
20
Objective: To evaluate the effectiveness and safety of minimally invasive treatment for bilateral tibial plateau fractures using the double reverse traction reducer.
Methods: The clinical data of 4 patients with bilateral tibial plateau fractures who met the selection criteria and treated between January 2016 and April 2024 were retrospectively analyzed. The cohort included 3 males and 1 female, aged 30-65 years (mean, 52.5 years). Injury mechanisms comprised traffic accidents (2 cases) and falls (2 cases). According to the Schatzker classification, 2 limbs were type Ⅱ and 6 were type Ⅵ. The time from injury to surgery ranged from 5 to 9 days (mean, 7 days). All patients underwent minimally invasive reduction using the double reverse traction reducer. Surgical duration, intraoperative blood loss, and hospitalization time were recorded. Functional outcomes were assessed at last follow-up using the Hospital for Special Surgery (HSS) knee score and range of motion (ROM), while fracture reduction quality was evaluated using the Rasmussen radiological score.
Results: All 4 patients successfully completed the procedure without conversion to open reduction. The total mean operation time was 80.25 minutes (range, 73-86 minutes), with a mean total intraoperative blood loss of 132.5 mL (range, 100-150 mL). The mean hospitalization time was 13.5 days (range, 11-16 days). All incisions healed primarily without neurovascular complications. X-ray film at 1 day after operation confirmed satisfactory reduction and articular surface alignment. Follow-up time ranged from 12 to 26 months (mean, 17.0 months). Fractures achieved clinical union at an average of 13 weeks (range, 12-16 weeks). No complication, such as deep vein thrombosis, joint stiffness, post-traumatic arthritis, or implant failure, was observed. At last follow-up, the mean HSS score was 92.9 (range, 90-97), mean knee ROM was 128.1° (range, 115°-135°), and mean Rasmussen radiological score was 16.4 (range, 15-19), with 2 limbs rated as excellent and 6 as good.
Conclusion: The double reverse traction reducer facilitates minimally invasive treatment of bilateral tibial plateau fractures with advantages including minimal trauma, shorter surgical duration, precise reduction, and fewer complications, effectively promoting fracture healing and functional recovery of the knee joint.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12279922 | PMC |
http://dx.doi.org/10.7507/1002-1892.202505053 | DOI Listing |
J Phys Chem Lett
September 2025
Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, China.
Achieving UVA/B-selective, skin-inspired nociceptors with perception and blockade functions at the single-unit device level remains challenging. This is because the device necessitates distinct components for every performance metric, thereby leading to complex preparation processes and restricted performance, as well as the absence of deep UV (UVB and below)-selective semiconductors. Here, to address this, we develop a structure-simplification skin-inspired nociceptor using a reverse type-II CuAgSbI/MoS heterostructure.
View Article and Find Full Text PDFMedicine (Baltimore)
September 2025
Department of Cardiac Surgery, Chest Hospital, Tianjin University, Tianjin, China.
Rationale: Tracheomalacia, typically seen in relapsing polychondritis,[1] is rarely reported in association with congenital heart disease (CHD). In patients with pulmonary hypoperfusion-type CHD, surgical repair results in a rapid increase in pulmonary blood flow, predisposing them to mucus retention, airway obstruction, and respiratory distress. We describe acute airway collapse in a patient with double outlet right ventricle and congenital bronchial stenosis following cardiac repair.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Advanced Materials Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China.
Improving electrostrain in lead-free piezoelectric materials is critical for practical use. This study examines KTN crystals and employs two primary strategies to enhance their electrostrain: (1) Cu doping creates a restoring force enabling reversible domain switching. (2) Polarizing Cu:KTN crystals and applying an electric field perpendicular to the polarization direction ensure that all domains contribute to the strain.
View Article and Find Full Text PDFBlood
September 2025
University of Illinois at Chicago, Chicago, Illinois, United States.
Hematopoietic stem cells (HSCs) responsible for blood cell production and their bone marrow regulatory niches undergo age-related changes, impacting immune responses and predisposing individuals to hematologic malignancies. Here, we show that the age-related alterations of the megakaryocytic niche and associated downregulation of Platelet Factor 4 (PF4) are pivotal mechanisms driving HSC aging. PF4-deficient mice display several phenotypes reminiscent of accelerated HSC aging, including lymphopenia, increased myeloid output, and DNA damage, mimicking physiologically aged HSCs.
View Article and Find Full Text PDFNano Lett
September 2025
State Key Laboratory of Materials Low-Carbon Recycling, College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, P. R. China.
Two-dimensional (2D) nanofluidic architectures with nanoconfined interlayer channels and excess surface charges have revolutionized membrane-based reverse electrodialysis systems, demonstrating highly efficient osmotic energy collection through strong electrostatic screening of electric double layer (EDL). However, the ion-transport dynamics in 2D nanofluidic anion-selective membranes (2D-NAMs) still remain unexplored. Here, we combine density functional theory and molecular dynamics (MD) simulations to systematically explore ion transport in the 2D-NAMs.
View Article and Find Full Text PDF