Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Sputum retention in pediatric pneumonia hinders recovery. This study evaluated the therapeutic benefits of incorporating mechanical vibration-assisted sputum clearance (MVSC) as an adjunct to standard pharmacological treatment and developed a nomogram to optimize treatment parameters.

Methods: In this randomized controlled trial, 160 children with pneumonia were randomly assigned (1:1) to a control group receiving pharmacological treatment or a treatment group receiving additional mechanical vibration therapy. The proportion of patients showing clinical improvement (defined as "markedly improved" or "improved") was assessed, along with symptom resolution times, lung function, blood gas parameters, and inflammatory markers, which were measured at baseline and treatment completion. LASSO regression identified predictors of clinical improvement.

Results: A significantly greater proportion of patients exhibited clinical improvement in the treatment group (93.75%) compared to the control group (75%,  < 0.05). The treatment group also showed significantly shorter times for symptom resolution (pulmonary rales, fever, and cough) and hospital stay ( < 0.05). Improvements in lung function (FEV1, FEV1/FVC), blood gas parameters (PaO₂, PaCO₂, pH), and greater reductions in inflammatory markers (CRP, PCT), were observed in the treatment group ( < 0.05). A nomogram was developed using age, chest circumference, moist rales, disease severity, vibration frequency, and pressure to determine optimal mechanical vibration settings for individualized treatment. The nomogram showed high predictive accuracy (AUC = 0.943) in estimating clinical improvement, aiding in the optimization of MVSC in pediatric pneumonia.

Conclusions: MVSC enhances the treatment of pediatric pneumonia, with the nomogram optimizing the parameters of the sputum clearance device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12240992PMC
http://dx.doi.org/10.3389/fped.2025.1539218DOI Listing

Publication Analysis

Top Keywords

mechanical vibration-assisted
8
vibration-assisted sputum
8
sputum clearance
8
pediatric pneumonia
8
randomized controlled
8
controlled trial
8
pharmacological treatment
8
control group
8
group receiving
8
treatment group
8

Similar Publications

Titanium alloys (Ti-6Al-4V) are widely used in the aerospace field. However, as a typical difficult-to-machine material, titanium alloys have a low thermal conductivity, a high chemical activity, and a significant adiabatic shear effect. In conventional milling (CM), the temperature in the cutting zone rises sharply, leading to tool adhesion, rapid wear, and damage to the workpiece surface.

View Article and Find Full Text PDF

Multi-Scale Study on Ultrasonic Cutting of Nomex Honeycomb Composites of Disc Cutters.

Materials (Basel)

July 2025

Division of Intelligent Instrument and Equipment, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.

To address the issues of burr formation, structural deformation, and tearing in the conventional machining of Nomex honeycomb composites, this study aims to clarify the mechanisms by which ultrasonic vibration-assisted cutting enhances machining quality. A multi-scale analysis framework is developed to examine the effects of ultrasonic vibration on fiber distribution, cell-level shear response, and the overall cutting mechanics. At the microscale, analyses show that ultrasonic vibration mitigates stress concentrations, thereby shortening fiber length.

View Article and Find Full Text PDF

Compliant mechanisms are often utilized in precise positioning systems but have not been thoroughly examined in vibration-aided fine CNC machining. This study aims to develop a new 02-DOF flexure stage for vibration-aided fine CNC milling. A hybrid displacement amplifier, featuring a two-lever mechanism, two Scott-Russell mechanisms, and a parallel leading mechanism, was integrated into a symmetric perpendicular series configuration to create an innovative design.

View Article and Find Full Text PDF

Background: Sputum retention in pediatric pneumonia hinders recovery. This study evaluated the therapeutic benefits of incorporating mechanical vibration-assisted sputum clearance (MVSC) as an adjunct to standard pharmacological treatment and developed a nomogram to optimize treatment parameters.

Methods: In this randomized controlled trial, 160 children with pneumonia were randomly assigned (1:1) to a control group receiving pharmacological treatment or a treatment group receiving additional mechanical vibration therapy.

View Article and Find Full Text PDF

Deformation mechanism and microstructure evolution of TC4 alloy during ultrasonic energy field-assisted deformation.

Ultrasonics

October 2025

State Key Laboratory of Materials Processing and Die & Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; Hubei Huangshi Mold Industrial Technology Research Institute, Huangshi 435007, China.

Ultrasonic vibration-assisted compression tests on TC4 alloy are performed at room temperature under various deformation and ultrasonic conditions. The influence of strain rate and Ultrasonic Energy Field (UEF) on plastic deformation behaviors and microstructure evolution is analyzed. The experimental results indicate that the flow stress exhibits a decreasing trend either with the decrease of strain rate or the application of UEF.

View Article and Find Full Text PDF