Article Abstract

Introduction: Accurate assessment of joint range of motion (ROM) is essential for diagnosing and managing upper extremity injuries. Universal goniometers are the most used tools for measuring ROM, but they require skilled observers and are limited by interobserver variability. An automated system for measuring joint range of motion from patient videos could facilitate standardized reporting of outcomes after reconstructive surgery.

Methods: An Automated Range of Motion Observer and Reporter (ARMOR) software was developed as an autonomous, video-based ROM measurement tool leveraging OpenCV pose estimation. ARMOR was used to assess upper extremity range of motion and was validated against photography-based (photogoniometry) and manual goniometry in a cohort of brachial plexus surgery patients.

Results: The correlation coefficients comparing ARMOR to manual goniometry were above 0.90 for all motion tasks, except for elbow flexion. For shoulder flexion, the mean difference between ARMOR and manual goniometry was more than 14° smaller than the difference for photogoniometry. Mean differences for shoulder abduction were similar between ARMOR and photogoniometry.

Conclusion: ARMOR's accuracy in assessing shoulder ROM, independence from human observer bias, and telemedicine compatibility makes it a promising solution for consistent and accessible ROM assessment. The autonomous nature of the software enhances the data collection workflow for clinical researchers while eliminating interrater variability.

Download full-text PDF

Source
http://dx.doi.org/10.5435/JAAOSGlobal-D-25-00088DOI Listing

Publication Analysis

Top Keywords

range motion
20
manual goniometry
12
automated range
8
motion observer
8
observer reporter
8
patient videos
8
joint range
8
upper extremity
8
armor manual
8
motion
6

Similar Publications

Alterations in skeletal muscle morphology and composition are critical factors in cerebral palsy (CP), including changes in passive stiffness and in belly and fascicle lengths. In this study, we quantified the relative contributions of muscle and tendon to passive stiffness across the ankle range of motion in individuals with CP and typically developing (TD) peers. We also investigated morphological factors underlying increased muscle stiffness.

View Article and Find Full Text PDF

IntroductionTo investigate the effectiveness of the remote video-based Strengthening and Stretching for Rheumatoid Arthritis of the Hand (SARAH) exercise program in individuals with rheumatoid arthritis (RA) with wrist involvement.MethodsSeventy-three individuals were included in the study. Wrist joint position sense, wrist joint range of motion, wrist pain, wrist morning stiffness, subjective and objective hand function, grip strength, and disease-related health status were assessed at baseline and after 12 weeks.

View Article and Find Full Text PDF

Strain sensors have received considerable attention in personal healthcare due to their ability to monitor real-time human movement. However, the lack of chemical sensing capabilities in existing strain sensors limits their utility for continuous biometric monitoring. Although the development of dual wearable sensors capable of simultaneously monitoring human motion and biometric data presents significant challenges, the ability to fabricate these sensors with geometries tailored to individual users is highly desirable.

View Article and Find Full Text PDF

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA), which is increasingly used to improve surgical precision, can face adoption difficulties due to a learning curve marked by longer operating times. The aim of this study was to evaluate the learning curve associated with the VELYS™ robot in five surgeons from the same centre with different annual arthroplasty volumes using navigated assistance with personalised alignment. The primary aim was to assess the learning curve for each surgeon.

View Article and Find Full Text PDF

Purpose: To assess the functional and subjective outcomes of combined anterior cruciate ligament reconstruction (ACLR) and lateral meniscal root tear (LMRT) repair. Additionally, to compare the use of an independent tunnel for LMRT repair with the ACL bone tunnel technique and to assess the failure rates of LMRT repair to isolated ACLR.

Methods: Patients who underwent primary ACLR and concomitant LMRT repair from May 2017 to May 2022 at Capio Artro Clinic, Stockholm, Sweden, were retrospectively identified and matched 1:3 (age, sex and graft type) with patients who underwent isolated ACLR during the same period.

View Article and Find Full Text PDF