Inter-AI Agreement in Measuring Cine MRI-Derived Cardiac Function and Motion Patterns: A Pilot Study.

J Imaging Inform Med

Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611, USA.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Manually analyzing a series of MRI images to obtain information about the heart's motion is a time-consuming and labor-intensive task. Recently, many AI-driven tools have been used to automatically analyze cardiac MRI. However, it is still unknown whether the results generated by these tools are consistent. The aim of the present study was to investigate the agreement of AI-powered automated tools for measuring cine MRI-derived cardiac function and motion indices. Cine MRI datasets of 23 healthy volunteers (10 males, 32.7 ± 11.3 years) were processed using heart deformation analysis (HDA, Trufistrain) and Circle CVI 42. The left and right ventricular (LV/RV) end-diastolic volume (LVEDV and RVEDV), end-systolic volume (LVESV and RVESV), stroke volume (LVSV and RVSV), cardiac output (LVCO and RVCO), ejection fraction (LVEF and RVEF), LV mass (LVM), LV global strain, strain rate, displacement, and velocity were calculated without interventions. Agreements and discrepancies of indices acquired with the two tools were evaluated from various aspects using t-tests, Pearson correlation coefficient (r), interclass correlation coefficient (ICC), and coefficient of variation (CoV). Systematic biases for measuring cardiac function and motion indices were observed. In global cardiac function indices, LVEF (56.9% ± 6.4 vs. 57.8% ± 5.7, p = 0.433, r = 0.609, ICC = 0.757, CoV = 6.7%) and LVM (82.7 g ± 21.6 vs. 82.6 g ± 18.7, p = 0.988, r = 0.923, ICC = 0.956, CoV = 11.7%) acquired with HDA and Circle seemed to be exchangeable. Among cardiac motion indices, circumferential strain rate demonstrated good agreements between two tools (97 ± 14.6 vs. 97.8 ± 13.6, p = 0.598, r = 0.89, ICC = 0.943, CoV = 5.1%). Cine MRI-derived cardiac function and motion indices obtained using different AI-powered image processing tools are related but may also differ. Such variations should be considered when evaluating results sourced from different studies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10278-025-01599-zDOI Listing

Publication Analysis

Top Keywords

cardiac function
20
function motion
16
motion indices
16
cine mri-derived
12
mri-derived cardiac
12
measuring cine
8
cardiac
8
strain rate
8
correlation coefficient
8
motion
6

Similar Publications

Background: This study aimed to investigate the gender-specific associations of skeletal muscle mass and fat mass with non-alcoholic fatty liver disease (NAFLD) and NAFLD-related liver fibrosis in two population-based studies.

Methods: Analyses were based on data from the MEGA (n = 238) and the MEIA study (n = 594) conducted between 2018 and 2023 in Augsburg, Germany. Bioelectrical impedance analysis was used to evaluate relative skeletal muscle mass (rSM) and SM index (SMI) as well as relative fat mass (rFM) and FM index (FMI); furthermore, the fat-to-muscle ratio was built.

View Article and Find Full Text PDF

Whole genome sequence analysis of low-density lipoprotein cholesterol across 246 K individuals.

Genome Biol

September 2025

Center for Genomic Medicine, Cardiovascular Research Center, , Massachusetts General Hospital Simches Research Center, 185 Cambridge Street, CPZN 5.238,, Boston, MA, 02114, USA.

Background: Rare genetic variation provided by whole genome sequence datasets has been relatively less explored for its contributions to human traits. Meta-analysis of sequencing data offers advantages by integrating larger sample sizes from diverse cohorts, thereby increasing the likelihood of discovering novel insights into complex traits. Furthermore, emerging methods in genome-wide rare variant association testing further improve power and interpretability.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the impact of asthma severity on biventricular cardiac functions using tissue Doppler imaging (TDI), two-dimensional speckle tracking echocardiography (2D-STE), and three-dimensional speckle tracking echocardiography (3D-STE).

Methods: Sixty-three children with asthma, aged between 5 and 16 years, were enrolled in the study along with 63 matched controls. All participants underwent cardiac assessments, including TDI, 2D-STE, 3D-STE, conventional echocardiography, and pulmonary function testing with spirometry.

View Article and Find Full Text PDF

Early repolarization pattern with oral liquid nicotine.

BMC Cardiovasc Disord

September 2025

Department of Cardiology II (Electrophysiology), University Hospital Münster, Albert-Schweitzer-Campus 1, Münster, 48149, Germany.

While most sudden cardiac deaths are due to structural heart disease or cardiac ischemia, intoxications are rather rare and often unrecognized. Here we present a case of a 35-year-old patient who trickled cumulative 60 mg of the pure nicotine liquid. This led to cardiac arrest and ventricular fibrillation.

View Article and Find Full Text PDF

The global surge in the population of people 60 years and older, including that in China, challenges healthcare systems with rising age-related diseases. To address this demographic change, the Aging Biomarker Consortium (ABC) has launched the X-Age Project to develop a comprehensive aging evaluation system tailored to the Chinese population. Our goal is to identify robust biomarkers and construct composite aging clocks that capture biological age, defined as an individual's physiological and molecular state, across diverse Chinese cohorts.

View Article and Find Full Text PDF