Article Abstract

Background: Metacarpophalangeal joint blocking orthoses are used for managing trigger finger, with limited intervention evidence for relative motion orthoses.

Purpose: This 6-week trial evaluated the effectiveness of metacarpophalangeal joint blocking and relative motion orthoses for managing trigger finger severity, function, occupational performance/satisfaction, and orthosis wearability.

Study Design: Randomized comparative trial, ClinicalTrials.gov (NCT05763017).

Methods: Thirty-six participants with no prior trigger finger intervention and ≥ 21 years old were randomly assigned to the relative motion or metacarpophalangeal joint blocking orthosis (neutral metacarpophalangeal joint) groups. The primary author screened for eligibility and fabricated the orthoses. Week-1 and week-6 Therapist A assessed stages of stenosing tenosynovitis, number of triggering events in 10 active fists (NTE), visual analog scales for pain, orthosis comfort and satisfaction (wearability), Disabilities of the Arm, Shoulder and Hand, and Canadian Occupational Performance Measure. Week-3 Therapist B administered orthosis wearability visual analog scales. The relative motion pencil test determined orthosis design, relative motion extension or flexion, and metacarpophalangeal joint differential. Mixed-effects ANOVA was used to compare week-1 and week-6 outcomes. Cohen's f was used to measure the effect size.

Results: Thirty-five participants completed this trial. Between week-1 and week-6, both groups demonstrated significant differences with large effect size in stages of stenosing tenosynovitis (f=1.21), NTE (f=1.07), pain at rest (f=0.36), pain during activity (f=0.76), Disabilities of the Arm, Shoulder and Hand (f=1.19), Canadian Occupational Performance Measure performance (f=1.12) and satisfaction (f=1.14). No superior effect was noted between orthosis groups. Wearability for both groups was 7/10 at rest and 4/10 during activity. The pencil test yielded 15/18 relative motion extension orthoses and 20-25˚ metacarpophalangeal differential.

Conclusions: Symptom severity, pain, hand function, and orthosis wearability outcomes support interchangeable use of relative motion and metacarpophalangeal joint blocking orthoses for managing trigger finger.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jht.2025.05.018DOI Listing

Publication Analysis

Top Keywords

relative motion
32
metacarpophalangeal joint
28
joint blocking
20
trigger finger
20
motion metacarpophalangeal
12
blocking orthoses
12
orthoses managing
12
managing trigger
12
week-1 week-6
12
randomized comparative
8

Similar Publications

Promiscuity, or selectivity on a spectrum, is an encoded feature in biomolecular anion recognition. To unravel the molecular drivers of promiscuous anion recognition, we have employed a comprehensive approach - spanning experiment and theory - with the Staphylococcus carnosus nitrate regulatory element A (ScNreA) as a model. Thermodynamic analysis reveals that ScNreA complexation with native nitrate and nitrite or non-native iodide is an exothermic process.

View Article and Find Full Text PDF

Family History-Guided Physical Activity for Cardiovascular Disease Prevention.

Am J Prev Med

September 2025

Exercise Intervention for Health Research Group (EXINH-RG), Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain; National Research Centre for the Working Environment, Copenhagen, Denmark; Department of Physical Medicine and Nursing, University of Zaragoza, Zaragoza, Spain.

Introduction: It remains unclear if individuals with a family history of cardiovascular disease (CVD) can achieve similar CVD incidence reductions through moderate-to-vigorous physical activity (MVPA) as those without a family history. The aim of the study was to investigate the importance of familial CVD history on the association of MVPA with CVD risk.

Methods: A prospective cohort from the UK Biobank who completed one week of accelerometer-based MVPA measurements from June 1, 2013, to December 23, 2015 was analyzed.

View Article and Find Full Text PDF

Emergent Self-Propulsion of Skyrmionic Matter in Synthetic Antiferromagnets.

Phys Rev Lett

August 2025

Universidade Federal de Pernambuco, Núcleo de Tecnologia, Centro Acadêmico do Agreste, Avenida Marielle Franco, Caruaru-PE, 55014-900, Brazil.

Self-propulsion plays a crucial role in biological processes and nanorobotics, enabling small systems to move autonomously in noisy environments. Here, we theoretically demonstrate that a bound skyrmion-skyrmion pair in a synthetic antiferromagnetic bilayer can function as a self-propelled topological object, reaching speeds of up to a hundred million body lengths per second-far exceeding those of any known synthetic or biological self-propelled particles. The propulsion mechanism is triggered by the excitation of back-and-forth relative motion of the skyrmions, which generates nonreciprocal gyrotropic forces, driving the skyrmion pair in a direction perpendicular to their bond.

View Article and Find Full Text PDF

Objective: Due to its inherent high instability, the selection of fixation strategies for unilateral Denis type II sacral fractures remains a controversial challenge in the field of traumatic orthopedics. This study focuses on unilateral Denis type II sacral fractures. By applying three different fixation methods, it aims to explore their biomechanical properties and provide a theoretical basis for optimizing clinical fixation protocols.

View Article and Find Full Text PDF

Understanding gastric physiology in rodents is critical for advancing preclinical neurogastroenterology research. However, existing techniques are often invasive, terminal, or limited in resolution. This study aims to develop a non-invasive, standardized MRI protocol capable of capturing whole-stomach dynamics in anesthetized rats with high spatiotemporal resolution.

View Article and Find Full Text PDF