A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Development and validation of a LC-MS/MS method for the simultaneous determination of simnotrelvir and ritonavir in human serum and bronchoalveolar lavage fluid. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

"Xiannuoxin" (simnotrelvir/ritonavir) is a novel anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) drug developed in China, which plays an antiviral role by inhibiting 3C-like protease (3CL). At present, it has been put into clinical use, while a simple, accurate and sensitive detection method is urgently needed for the quantification of simnotrelvir/ritonavir in human serum and bronchoalveolar lavage fluid (BALF) to ensure safe and efficacious antiviral therapeutics. In this study, we developed a liquid chromatography tandem mass spectrophotometry (LC-MS/MS) method for the simultaneous determination of simnotrelvir, ritonavir and urea concentrations in human serum and BALF samples. Prior to LC-MS/MS analysis, a user-friendly, one-step pre-analytical process was conducted, followed by a rapid chromatographic run lasting 3 min. This was then succeeded by positive and negative electrospray ionization and detection using a triple quadrupole tandem mass spectrometer in the multiple reaction monitoring mode. Subsequently, the LC-MS/MS method underwent a comprehensive validation in aspects such as sensitivity (LoQs of 2.5 ng/mL, 0.1 ng/mL, and 1 μg/mL for simnotrelvir, ritonavir and urea), linearity, carryover, precision, trueness (recovery rates of simnotrelvir, ritonavir and urea were between 85 and 115%), matrix effect (within 85-115%) and stability (stable for 72 h at room temperature). The validation results demonstrated that this LC-MS/MS method was robust and reliable. Notably, we can use the urea dilution correction method to calculate the concentrations of simnotrelvir and ritonavir in epithelial lining fluid (ELF), which is of great significance for evaluating the effectiveness and safety of antiviral drug treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12224748PMC
http://dx.doi.org/10.1186/s13065-025-01534-xDOI Listing

Publication Analysis

Top Keywords

simnotrelvir ritonavir
20
lc-ms/ms method
16
human serum
12
ritonavir urea
12
method simultaneous
8
simultaneous determination
8
determination simnotrelvir
8
serum bronchoalveolar
8
bronchoalveolar lavage
8
lavage fluid
8

Similar Publications