98%
921
2 minutes
20
The landmark Diabetes Control and Complications Trial (DCCT) showed that glucose control is critical to reducing the risk of diabetes-related complications. This chapter outlines a series of innovations and investigations that followed the DCCT, aimed at minimizing the risk of hypoglycemia while further improving glucose control. The chapter presents an example of innovations in wired enzyme technology that facilitated the movement from capillary glucose monitoring to continuous glucose monitoring (CGM) and ultimately, the first-factory calibrated CGM system. The next glycemic management innovation was to connect CGM data to an insulin pump containing an algorithm able to adjust insulin delivery based on the changing glucose levels and trends. The key features of automated insulin delivery (AID) systems, currently approved in the United States, are presented. The AID summary table includes type of pump, type and function of the insulin delivery algorithm, the data management system, and the indications for use. The next section explores the innovation of alternative routes of insulin delivery to move toward the goal of a fully automated insulin delivery system. The main trials in developing and implementing an implantable intraperitoneal programmable system are summarized. The last section explores if sensor input in addition to glucose levels such as continuous sensing of ketone, lactate, or insulin levels may provide valuable feedback to move us closer to a fully autonomous AID system. Much of this diabetes innovation and investigation work has been supported by the National Institute of Diabetes and Digestive and Kidney Diseases over that last 75 years.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/19322968251342239 | DOI Listing |
Diabetes Obes Metab
September 2025
Diabetes Care Unit, Nancy University Hospital, Nancy, France.
Aims: To assess the frequency and management of hypoglycaemia during unstructured physical activity (PA) in adults with type 1 diabetes (T1D) using automated insulin delivery (AID) systems in real-life settings.
Materials And Methods: RAPPID is a prospective, multicenter, observational study conducted over 1 month in four French tertiary care centres. Adults with T1D using one of three AID systems (MiniMed 780G, Tandem t:slim X2 with Control-IQ, or Ypsopump with CamAPS FX) and performing ≥2 unstructured PA sessions per week were included.
Diabet Med
September 2025
Edinburgh Centre for Endocrinology & Diabetes, NHS Lothian, Edinburgh, UK.
Aims: This study aimed to assess the impact of the Omnipod 5 automated insulin delivery (AID) system on continuous glucose monitoring (CGM) metrics, HbA1c, and weight in a real-world setting. Additionally, independent predictors of glycaemic response were assessed.
Methods: Observational analysis of adults with type 1 diabetes using Omnipod 5 (n = 353).
Diabetologia
September 2025
Center for Clinical Metabolic Research, Gentofte Hospital, University of Copenhagen, Hellerup, Denmark.
Aims/hypothesis: Alpha cell dysregulation is an integral part of type 2 diabetes pathophysiology, increasing fasting as well as postprandial glucose concentrations. Alpha cell dysregulation occurs in tandem with the development of insulin resistance and changes in beta cell function. Our aim was to investigate, using mathematical modelling, the role of alpha cell dysregulation in beta cell compensatory insulin secretion and subsequent failure in the progression from normoglycaemia to type 2 diabetes defined by ADA criteria.
View Article and Find Full Text PDFAdv Pharm Bull
July 2025
Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal- 576104, India.
Purpose: The present study aimed to fabricate microneedles (MNs) for transdermal delivery of insulin. Chitosan-conjugated carboxy phenyl boronic acid polymer was synthesized and characterized to load insulin in the form of nanoparticles.
Methods: Optimized insulin nanoparticles (ILN-NPs) were loaded into MN arrays by micromolding, and the resulting MN patches were characterized by scanning electron microscopy (SEM) and mechanical failure tests.
JAMA Pediatr
September 2025
Diabetes Research Envisioned and Accomplished in Manitoba (DREAM) Research Theme, Children's Hospital Research Institute of Manitoba, Winnipeg, Canada.
Importance: Youth living with type 1 diabetes (T1D) are increasingly choosing automated insulin delivery (AID) systems to manage their blood glucose. Few systematic reviews meta-analyzing results from randomized clinical trials (RCTs) are available to guide decision-making.
Objective: To study the association of prolonged AID system use in an outpatient setting with measures of glucose management and quality of life in youth with T1D.