Using dual-energy computed tomography (CT), this study aims to develop an algorithm to identify the chemical constituents of an unknown material (compound or mixture) and improve the accuracy of material discrimination. The algorithm requires mass attenuation coefficients (MAC) that were obtained using a dual energy CT as an input, identifies the elemental composition, and then calculates its weight fraction. To evaluate the functionality of the developed algorithm, it was used to determine the chemical constituents for human tissues. Furthermore, the results were compared with those provided by the National Institute of Standards and Technology (NIST). We used dual energies 80/140 kVp for spectral CT scans, as inputs to the algorithm, in addition to a set of 50/80 and 80/100 keV for mono-energetic X-rays. The algorithm correctly determined the chemical constituent elements of unknown materials. Results were obtained for the fractional weights of each component for mono-energetic X-rays and spectral X-ray use. For mono-energetic X-rays, the differences were < 0.01% for compounds and 6.02% for mixture, respectively. For the spectral X-rays, the differences in 2.98% for compounds and 6.03% for mixtures, respectively. We developed an algorithm to determine the type and weight fraction of an element using the MAC of dual-energy CT. The algorithm can exclude the inherent uncertainty of SPR calculations and improve the accuracy of dose calculations in radiation therapy planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12208427PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0322805PLOS

Publication Analysis

Top Keywords

mono-energetic x-rays
12
dual energy
8
computed tomography
8
determine chemical
8
chemical constituents
8
algorithm
6
algorithm dual
4
energy computed
4
tomography determine
4
chemical
4

Similar Publications

Introduction: Recent advances in portable X-ray fluorescence (XRF) have opened up the possibility of a rapid and cost-effective method for measuring elemental content in nail clippings. Two elements of particular interest for intake assessment through nail clipping measurement are zinc and selenium. The New Zealand-based Mother and Infant Nutrition Investigation (MINI) provides an ideal testing ground for the application of portable XRF in the measurement of zinc and selenium.

View Article and Find Full Text PDF

Background: With the ever-increasing dependence on cone-beam CT (CBCT) for clinical decision-making, faster and more accurate CBCT simulation tools are necessary to develop the next generation of CBCT techniques and algorithms.

Purpose: GECCO, a hybrid GPU-Monte Carlo (MC) software toolkit was built for the dual purpose of increasing both speed and accuracy in CBCT simulation. GECCO contains two applications: The GECCO application, a rapid converter of CT to CBCT, and the real-time image simulation (RTIS) application, a purely analytical approach that updates CBCT images in real-time according to acquisition technique.

View Article and Find Full Text PDF

Objective: To investigate the diagnostic performance of dual-layer spectral detector CT (DLCT) in differentiating middle ear cholesteatoma and chronic suppurative otitis media (CSOM).

Materials And Methods: This prospective, institutional review board-approved study consecutively enrolled patients with suspected middle ear cholesteatoma or CSOM from January to July 2024. All participants underwent DLCT scanning before surgery.

View Article and Find Full Text PDF

Purpose: Contrast-enhanced dual energy CT, with low-mono-energetic CT scanning (conventional 70 keV and low-mono energetic 40 keV) can improve visualization of acute inflammatory processes, but the high iodine attenuation often requires adjustment of window display settings to optimize interpretation. Here, we aim to determine optimal keV and window settings for the visualization of acute appendicitis from images derived from low-mono-energetic-CT.

Methods: 34 patients diagnosed with appendicitis, using dual energy CT, were retrospectively identified.

View Article and Find Full Text PDF

Using dual-energy computed tomography (CT), this study aims to develop an algorithm to identify the chemical constituents of an unknown material (compound or mixture) and improve the accuracy of material discrimination. The algorithm requires mass attenuation coefficients (MAC) that were obtained using a dual energy CT as an input, identifies the elemental composition, and then calculates its weight fraction. To evaluate the functionality of the developed algorithm, it was used to determine the chemical constituents for human tissues.

View Article and Find Full Text PDF