A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

[Research progress in biomechanics of different fixation methods for medial opening-wedge high tibial osteotomy]. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To summarize the biomechanical research progress on different fixation methods in medial opening-wedge high tibial osteotomy (MOWHTO) and provide references for selecting appropriate fixation methods in clinical applications of MOWHTO for treating knee osteoarthritis (KOA).

Methods: Recent domestic and international literature on the biomechanical studies of MOWHTO fixation methods was reviewed to analyze the characteristics and biomechanical performance of various fixation techniques.

Results: The medial-specific osteotomy plate system has become the mainstream due to its high stiffness and stability, but issues such as soft tissue irritation and stress shielding remain. The use of filler blocks significantly enhances fixation stability and promotes bone healing when the osteotomy gap is large, reducing axial displacement by 73%-76% and decreasing plate stress by 90%. Auxiliary screws improve axial and torsional stability, particularly in cases with large correction angles, effectively preventing lateral hinge fractures. Alternative fixation methods like external fixators hold unique clinical value by minimizing soft tissue irritation and allowing postoperative adjustment.

Conclusion: There is currently no unified standard for selecting MOWHTO fixation methods. Clinical decisions should comprehensively consider factors such as bone quality, correction angle, and postoperative rehabilitation needs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12179256PMC
http://dx.doi.org/10.7507/1002-1892.202504010DOI Listing

Publication Analysis

Top Keywords

fixation methods
24
fixation
8
methods medial
8
medial opening-wedge
8
opening-wedge high
8
high tibial
8
methods clinical
8
mowhto fixation
8
soft tissue
8
tissue irritation
8

Similar Publications