A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Wearable ultrasound regulation of blood glucose levels in type 2 diabetic db/db mice. | LitMetric

Wearable ultrasound regulation of blood glucose levels in type 2 diabetic db/db mice.

Ultrasonics

School of the State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China; Department of the National Engineering Research Center of Ultrasound Medicine, Chongqing 401121, China. Electronic address: lifq@cqm

Published: November 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Type 2 diabetes mellitus (T2DM), a chronic metabolic disorder, imposes a notable burden on human health. Current treatments that require long-term medication and dietary control often face challenges with patient compliance. Although low-intensity pulsed ultrasound (LIPUS) shows promise in regulating blood glucose, the clinical application of traditional ultrasound devices remains challenging due to their large size and high cost. Through theoretical simulation, we designed and fabricated a wearable ultrasound patch with a frequency of 986 kHz and its wearable driving device for use in blood glucose regulation in db/db mice. The liver-pancreas region of the db/db mice was exposed to the wearable ultrasound device with the following parameters: frequency at 986 kHz, duty cycle at 30 %, pulse repetition frequency of 2 kHz, I of 86.81 mW/cm, and 10-min duration. Results showed that LIPUS-treated db/db mice exhibited a prolonged time for blood glucose to return to baseline levels after 8-week LIPUS exposure. Improved glucose tolerance, reduced insulin resistance, and decreased body weight were also observed. Liver morphology was well maintained, demonstrating LIPUS effectiveness in regulating blood glucose in db/db mice. Biological safety tests indicated no adverse effects on the tissues. This study demonstrates that the use of a wearable ultrasound device, through low-intensity pulsed ultrasound (LIPUS), can effectively regulate blood glucose levels in db/db mice. Our approach offers a noninvasive solution for regulating blood glucose levels in patients with T2DM and holds promise for ultrasound application in metabolic disease treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2025.107739DOI Listing

Publication Analysis

Top Keywords

blood glucose
28
db/db mice
24
wearable ultrasound
16
glucose levels
12
regulating blood
12
glucose
8
low-intensity pulsed
8
pulsed ultrasound
8
ultrasound lipus
8
frequency 986 khz
8

Similar Publications