Development of a text message intervention designed to promote safe contact lens wear.

Ophthalmic Physiol Opt

School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, New South Wales, Australia.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Some contact lens wearers demonstrate poor compliance with hygiene behaviours which increase their risk of corneal infection. Text message interventions for behaviour change can provide support and education in healthcare domains. This study reports on the co-design of a text message intervention to target hygiene compliance, user satisfaction and discontinuation in contact lens wear.

Methods: In phase 1, draft messages were composed using contact lens compliance advice from peak bodies, which was then optimised for persuasion using behaviour change theory. Phase 2 involved consultation with Patient Advocates (3), Health Psychology Experts (5) and Eyecare Practitioners (11), who rated messages (Likert 1-6) on readability, appropriateness, behaviour change and provided comments. Lay contact lens wearers participated in focus groups (2-4 per group) and provided feedback on relevance, comprehension and likely behaviour change. Phase 3 assessed messages and modified for readability (Flesh-Kincaid). Phase 4 created and pilot tested (n = 5 users) text message sequences.

Results: Phase 1 created 95 messages. In Phase 2, ratings (1-6) of readability (M = 5.4, SD = 0.5), appropriateness (M = 5.3 SD = 0.6) and likelihood to change behaviour (M = 5.0, SD = 0.6) combined with free text comments led to the modification of 59/95 (62%) messages, including the deletion of five messages. Focus group participants (5 groups, n = 14) suggested engagement, educational content and simplification. Most (62/90, 69%) messages were modified, four removed and two new messages proposed. In Phase 3, 88% were assessed as fairly easy or better. Post-modification, all messages were fairly easy, mean readability 82.1 (range: 73.7-91.8, SD = 5.8). Phase 4 created 17 sequences of text messages and pilot testing established the process for replies, opt-outs and modified time-zone delivery.

Conclusion: Co-designing and evaluating text messages was feasible, resulting in a library of 88 optimised text messages formed into semi-personalised sequences.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12357223PMC
http://dx.doi.org/10.1111/opo.13538DOI Listing

Publication Analysis

Top Keywords

contact lens
20
text message
16
behaviour change
16
messages
12
phase created
12
text messages
12
message intervention
8
lens wearers
8
phase
8
1-6 readability
8

Similar Publications

As emerging technologies reshape both the body and how we represent it, anatomical education stands at a threshold. Virtual dissection tools, AI-generated images, and immersive platforms are redefining how students learn anatomy, while real-world bodies are becoming hybridized through implants, neural interfaces, and bioengineered components. This Viewpoint explores what it means to teach human anatomy when the body is no longer entirely natural, and the image is no longer entirely real.

View Article and Find Full Text PDF

Scleral Lens and Suture Erosion in Scleral-Sutured Posterior Chamber Intraocular Lens.

Eye Contact Lens

September 2025

Department of Ophthalmology, Mayo Clinic Alix School of Medicine (H.P.N.), Mayo Clinic in Arizona, Scottsdale, AZ; and Department of Ophthalmology (O.M.H., D.R.P., E.R.K., J.F.S.), Mayo Clinic in Arizona, Scottsdale, AZ.

This case series reports two cases of scleral lens (SL)-associated suture erosion of polytetrafluoroethylene CV-8 (Gore-Tex, Newark, DE) in scleral-sutured CZ70BD (Alcon, Fort Worth, TX) posterior chamber intraocular lens (SS-PCIOL). Suture erosion after SS-PCIOL has been reported in two of the patients who were fitted with SL for visual acuity improvement. Erosion was corrected in both cases with suture repositioning and corneal patch graft, with one patient requiring the exchange of the intraocular lens.

View Article and Find Full Text PDF

Unlabelled: Contact lens wear in humans and mice is consistently associated with asymptomatic corneal parainflammation. Here, we tested the hypothesis that the corneal response to lens wear alone can function to protect it against bacterial adhesion enabled by superficial injury. One eye only of mT/mG-LysMcre mice (cell membranes red; Lyz2 cells green) wore a contact lens for 4-6 days.

View Article and Find Full Text PDF

A Clinical Evaluation of Lifitegrast Ophthalmic Solution 5% in Symptomatic Contact Lens Wearers.

Clin Ophthalmol

August 2025

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.

Purpose: To evaluate the effectiveness of lifitegrast ophthalmic solution 5% in alleviating end-of-day dryness and discomfort in symptomatic contact lens (CL) wearers.

Patients And Methods: This was an open-label study in symptomatic CL wearers with ratings of ≥40 for end-of-day dryness on a visual analog scale (VAS; 0-100 scale; 100 worst). Participants wore their habitual CLs and instilled lifitegrast twice daily for 12 weeks with lenses removed.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.

Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.

View Article and Find Full Text PDF