98%
921
2 minutes
20
Introduction: Some contact lens wearers demonstrate poor compliance with hygiene behaviours which increase their risk of corneal infection. Text message interventions for behaviour change can provide support and education in healthcare domains. This study reports on the co-design of a text message intervention to target hygiene compliance, user satisfaction and discontinuation in contact lens wear.
Methods: In phase 1, draft messages were composed using contact lens compliance advice from peak bodies, which was then optimised for persuasion using behaviour change theory. Phase 2 involved consultation with Patient Advocates (3), Health Psychology Experts (5) and Eyecare Practitioners (11), who rated messages (Likert 1-6) on readability, appropriateness, behaviour change and provided comments. Lay contact lens wearers participated in focus groups (2-4 per group) and provided feedback on relevance, comprehension and likely behaviour change. Phase 3 assessed messages and modified for readability (Flesh-Kincaid). Phase 4 created and pilot tested (n = 5 users) text message sequences.
Results: Phase 1 created 95 messages. In Phase 2, ratings (1-6) of readability (M = 5.4, SD = 0.5), appropriateness (M = 5.3 SD = 0.6) and likelihood to change behaviour (M = 5.0, SD = 0.6) combined with free text comments led to the modification of 59/95 (62%) messages, including the deletion of five messages. Focus group participants (5 groups, n = 14) suggested engagement, educational content and simplification. Most (62/90, 69%) messages were modified, four removed and two new messages proposed. In Phase 3, 88% were assessed as fairly easy or better. Post-modification, all messages were fairly easy, mean readability 82.1 (range: 73.7-91.8, SD = 5.8). Phase 4 created 17 sequences of text messages and pilot testing established the process for replies, opt-outs and modified time-zone delivery.
Conclusion: Co-designing and evaluating text messages was feasible, resulting in a library of 88 optimised text messages formed into semi-personalised sequences.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12357223 | PMC |
http://dx.doi.org/10.1111/opo.13538 | DOI Listing |
Anat Sci Educ
September 2025
Human Anatomy, Vita-Salute San Raffaele University, Milan, Italy.
As emerging technologies reshape both the body and how we represent it, anatomical education stands at a threshold. Virtual dissection tools, AI-generated images, and immersive platforms are redefining how students learn anatomy, while real-world bodies are becoming hybridized through implants, neural interfaces, and bioengineered components. This Viewpoint explores what it means to teach human anatomy when the body is no longer entirely natural, and the image is no longer entirely real.
View Article and Find Full Text PDFEye Contact Lens
September 2025
Department of Ophthalmology, Mayo Clinic Alix School of Medicine (H.P.N.), Mayo Clinic in Arizona, Scottsdale, AZ; and Department of Ophthalmology (O.M.H., D.R.P., E.R.K., J.F.S.), Mayo Clinic in Arizona, Scottsdale, AZ.
This case series reports two cases of scleral lens (SL)-associated suture erosion of polytetrafluoroethylene CV-8 (Gore-Tex, Newark, DE) in scleral-sutured CZ70BD (Alcon, Fort Worth, TX) posterior chamber intraocular lens (SS-PCIOL). Suture erosion after SS-PCIOL has been reported in two of the patients who were fitted with SL for visual acuity improvement. Erosion was corrected in both cases with suture repositioning and corneal patch graft, with one patient requiring the exchange of the intraocular lens.
View Article and Find Full Text PDFUnlabelled: Contact lens wear in humans and mice is consistently associated with asymptomatic corneal parainflammation. Here, we tested the hypothesis that the corneal response to lens wear alone can function to protect it against bacterial adhesion enabled by superficial injury. One eye only of mT/mG-LysMcre mice (cell membranes red; Lyz2 cells green) wore a contact lens for 4-6 days.
View Article and Find Full Text PDFClin Ophthalmol
August 2025
Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada.
Purpose: To evaluate the effectiveness of lifitegrast ophthalmic solution 5% in alleviating end-of-day dryness and discomfort in symptomatic contact lens (CL) wearers.
Patients And Methods: This was an open-label study in symptomatic CL wearers with ratings of ≥40 for end-of-day dryness on a visual analog scale (VAS; 0-100 scale; 100 worst). Participants wore their habitual CLs and instilled lifitegrast twice daily for 12 weeks with lenses removed.
Clin Ophthalmol
August 2025
Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, BC, Canada.
Purpose: This study aims to evaluate rotational stability and patient-reported outcomes associated with Tecnis Eyhance toric II "monofocal plus" intraocular lens (IOL), particularly in light of a modified haptic design.
Methods: A prospective, interventional study was conducted with patients undergoing routine cataract surgery and Tecnis Eyhance toric II IOL implantation. The inclusion criteria were topographic corneal astigmatism of 0.