Article Abstract

The latest-generation Poly(L-lactic acid) (PLLA) based fully bioresorbable stents (BRS) are facing a grave challenge due to their higher clinical risk of post-implantation. There is consensus that the strut thickness of BRS far exceeds that of metal stents; this is the main reason for the poor clinical outcomes. Therefore, overcoming the gap in mechanical properties between PLLA and metal, and effectively reducing the strut thickness of BRS without sacrificing mechanical properties, is a research priority. In this paper, the vital structural weakness of BRS causing the poor mechanical properties was discovered from the preparation process. We proposed the use of an elastomeric coating to alleviate the damage in weakness during deployment. Experiments and numerical simulations conducted on PLLA stents with and without poly(L-lactide-co-ε-caprolactone) (PLCL) coating have confirmed that they can reduce stress concentration during deployment. The composite stents exhibit higher radial supporting capability after deployment. Significantly, the radial strength of the 100 μm thin-strut stent increased by 31%, up to 1061.8 mmHg. Moreover, in vivo animal experiments conducted on rabbits show encouraging biocompatibility and effectiveness of the composite stents. Our work provided a pure thin-strut PLLA stent with superior mechanical properties and biocompatibility, which can become a reliable platform for future research and clinical applications of BRS.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bip.70034DOI Listing

Publication Analysis

Top Keywords

mechanical properties
20
strut thickness
8
thickness brs
8
composite stents
8
stents
6
mechanical
5
properties
5
brs
5
bioresorbable composite
4
composite polymeric
4

Similar Publications

The mechanical properties of the polymeric substrate or matrix where a cell grows affect cell behavior. Most studies have focused on relating elastic properties of polymeric substrates, which are time-independent, to cell behaviors. However, polymeric substrates and biological systems exhibit a time-dependent, often viscoelastic, mechanical response.

View Article and Find Full Text PDF

Globular proteins as functional-mechanical materials: a multiscale perspective on design, processing, and applications.

Mater Horiz

September 2025

MOE Key Laboratory of Macromolecule Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, PR China.

Globular proteins, traditionally regarded as non-structural biomolecules due to the limited load-bearing capacity in their monomeric states, are increasingly recognized as valuable building blocks for functional-mechanical materials. Their inherent bioactivity, chemical versatility, and structural tunability enable the design of materials that combine biological functionality with tailored mechanical performance. This review highlights recent advances in engineering globular proteins-spanning natural systems (serum albumins, enzymes, milk globulins, silk sericin, and soy protein isolates) to recombinant architectures including tandem-repeat proteins-into functional-mechanical platforms.

View Article and Find Full Text PDF

Strain-induced half-metallicity and giant Wiedemann-Franz violation in monolayer NiI.

Phys Chem Chem Phys

September 2025

Departamento de Física, Universidad Técnica Federico Santa María, Av. España 1680, Casilla 110V, Valparaíso, Chile.

Reversible control of spin-dependent thermoelectricity mechanical strain provides a platform for next-generation energy harvesting and thermal logic circuits. Using first-principles and Boltzmann transport calculations, we demonstrate that monolayer NiI undergoes a strain-driven semiconductor-to-half-metal transition, enabled by the selective closure of its spin-down band gap while preserving a robust ferromagnetic ground state. Remarkably, this transition is accompanied by a giant, non-monotonic violation of the Wiedemann-Franz law, with the Lorenz number enhanced up to 7.

View Article and Find Full Text PDF

The development of mechanically robust, biocompatible, and biodegradable hydrogels remains a significant challenge for biomedical applications involving load-bearing soft tissues. Herein, a tubular lignin-derived hydrogel is engineered to assess its physicochemical, mechanical, and biological properties. Kraft and organosolv lignin are systematically compared at varying crosslinker concentrations to determine their effect on pore morphology, swelling behavior, and mechanical performance.

View Article and Find Full Text PDF

This study presents a comprehensive first-principles and device-performance investigation of alkali metal-based anti-perovskites ZBrO (Z = K, Rb, Cs, and Fr) for advanced optoelectronic and photovoltaic applications. Using density functional theory (DFT) with GGA-PBE and mGGA-rSCAN functionals, we analyzed the structural, electronic, optical, mechanical, phonon, population, and thermoelectric properties of these compounds. All ZBrO materials exhibit direct band gaps and strong optical absorption in the visible-UV spectrum.

View Article and Find Full Text PDF