98%
921
2 minutes
20
In recent years, semi-supervised methods have been rapidly developed for three-dimensional (3D) medical image analysis. However, previous semi-supervised methods for three-dimensional medical images usually focused on single-view information and required a large number of annotated datasets. In this paper, we innovatively propose a multi-view (coronal and transverse) attention network for semi-supervised 3D cardiac image segmentation. In this way, the proposed method obtained more complementary segmentation information, which improved the segmentation performance. Simultaneously, we integrated the CBAM module and adaptive channel attention block into the 3D VNet (CBAP - VNet) to enhance the focus on the segmentation regions and edge portions. We first introduced the CutMix data augmentation mechanism to enhance 3D cardiac medical image segmentation. In this way, the proposed method made full use of the mixed regions in the images and expanded the training dataset. Our method was tested on two publicly available cardiac datasets and achieved good segmentation results. Our code and models are available at https://github.com/HuaidongLi-NEFU/TPSSAN.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12119566 | PMC |
http://dx.doi.org/10.3389/fcvm.2025.1461774 | DOI Listing |
BMC Oral Health
September 2025
Oral and Maxillofacial Radiology Department, Cairo university, Cairo, Egypt.
Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.
Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.
Eur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.
Eur J Cancer
August 2025
Emory University, Atlanta, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA; Atlanta Veterans Administration Medical Center, Atlanta, USA. Electronic address:
Background: Early detection of hematological malignancies improves long-term survival but remains a critical challenge due to heterogeneity in clinical presentation. Chronic inflammation is a key driver in hematologic cancers and is known to induce compensatory microvascular changes. High-resolution, non-invasive retinal imaging can allow the quantification of microvascular changes for the early detection of hematological malignancies.
View Article and Find Full Text PDFEur J Ophthalmol
September 2025
vEyes NPO, vEyes Lab, Milo, Italy.
PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.
View Article and Find Full Text PDFJpn J Ophthalmol
September 2025
Department of Ophthalmology, Osaka University Graduate School of Medicine, Room E7, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
Abtract: PURPOSE: To evaluate the correlation between corneal backscatter and visual function in patients with Fuchs endothelial corneal dystrophy (FECD).
Study Design: Prospective case series.
Methods: This study included 53 eyes from 38 patients with FECD.