A Digital Signal Processing-Based Multi-Channel Acoustic Emission Acquisition System with a Simplified Analog Front-End.

Sensors (Basel)

School of Mechatronics and Vehicle Engineering, East China Jiaotong University, Nanchang 330013, China.

Published: May 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Advanced multi-channel acoustic emission (AE) monitoring systems often rely on complex and costly architectures, especially those requiring custom FPGA-based hardware. In this work, we present a digital signal processing (DSP)-based approach to high-performance AE acquisition, implemented using a simplified analog front-end (AFE) and a commercially available synchronous data acquisition (DAQ) card (NI USB-6356). This design eliminates the need for specialized FPGA development, improving accessibility and reducing system complexity. A key feature of the system is the replacement of traditional analog filters with a software-defined digital band-pass filtering module implemented in LabVIEW. This allows for real-time or post-processing filtering with adjustable parameters, enhancing flexibility in data analysis. The system supports 8-channel synchronous sampling at 1.25 MS/s, and performance evaluations demonstrate a dynamic range of 79.22 dB and a signal-to-noise ratio (SNR) of 85.39 dB. These results confirm the system's ability to maintain high fidelity in AE signal acquisition without the need for dedicated hardware filtering or custom DAQ hardware. The proposed method offers a practical and validated alternative for multi-channel AE monitoring, with potential applications in structural health monitoring, materials testing, and other engineering domains.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12116094PMC
http://dx.doi.org/10.3390/s25103206DOI Listing

Publication Analysis

Top Keywords

digital signal
8
multi-channel acoustic
8
acoustic emission
8
simplified analog
8
analog front-end
8
signal processing-based
4
processing-based multi-channel
4
acquisition
4
emission acquisition
4
system
4

Similar Publications

Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.

Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.

View Article and Find Full Text PDF

Purpose: Depression among college students is a growing concern that negatively affects academic performance, emotional well-being, and career planning. Existing diagnostic methods are often slow, subjective, and inaccessible, underscoring the need for automated systems that can detect depressive symptoms through digital behavior, particularly on social media platforms.

Method: This study proposes a novel natural language processing (NLP) framework that combines a RoBERTa-based Transformer with gated recurrent unit (GRU) layers and multimodal embeddings.

View Article and Find Full Text PDF

There is limited understanding of the impact of anti-IL5 treatment on nasal polyp tissue biology in chronic rhinosinusitis with nasal polyps (CRSwNP). This study examined nasal polyp tissue cellular proteome and transcriptome responses to anti-IL5 treatment in CRSwNP utilising spatial profiling. GeoMx™ Digital Spatial Profiling (DSP) of 80 proteins and 1,833 mRNA targets in the polyp stroma and the whole transcriptome (18,815 mRNA targets) in polyp epithelia was undertaken on sinonasal biopsies collected from 20 individuals with eosinophilic CRSwNP before and after 16 and 24 weeks of mepolizumab treatment.

View Article and Find Full Text PDF

Rationale: Nocardia spp. are opportunistic pathogens that invade the human body via respiratory inhalation or direct skin wounds. Spinal nocardial osteomyelitis is a rare disease with only a few cases reported to date.

View Article and Find Full Text PDF

Ingestible biosensors for drug delivery monitoring.

Prog Mol Biol Transl Sci

September 2025

School of Forensic Science, National Forensic Sciences University, Gandhinagar, Gujarat, India.

Ingestible biosensors are a mix of advanced biomedical engineering, digital health and precision pharmacotherapy. These miniaturised electronic devices are encapsulated in biocompatible materials, which operate within gastrointestinal (GI) tract. This enables real-time monitoring of pharmacological and physiological parameters.

View Article and Find Full Text PDF