A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

UTransBPNet for cuffless and calibration-free blood pressure estimation under dynamic conditions. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Accurate cuffless blood pressure (BP) estimation remains challenging, particularly under dynamic conditions with significant intra-individual BP variations. This study introduces UTransBPNet, a novel, calibration-free model for cuffless BP estimation. It integrates a squeeze-and-excitation-enhanced Unet architecture for short-range feature extraction with a transformer and cross attention module to capture long-range dependencies from high-resolution, multi-channel physiological signals, further refined through an optimized fine-tuning scheme. Comprehensive validations were conducted across multiple dynamic datasets-Dataset_Drink, Dataset_Exercise, and Dataset_MIMIC-in both scenario-specific and cross-scenario settings. Results demonstrate that UTransBPNet outperformed existing models in tracking BP variations under dynamic conditions, achieving individual Pearson's correlation coefficients of 0.61 ± 0.17 and 0.62 ± 0.13 for systolic BP (SBP) and diastolic BP (DBP) in Dataset_Drink, 0.82 ± 0.11 and 0.72 ± 0.18 in Dataset_Exercise, and low mean absolute differences (MADs) of 4.38 and 2.25 mmHg in Dataset_MIMIC. The analysis also highlights the impact of dataset characteristics on model performance, such as distribution shift, distribution imbalance and individual BP variability, highlighting the need for well-curated data to ensure generalizability. This study advances the development of robust, cuffless BP estimation models for real-world applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12095506PMC
http://dx.doi.org/10.1038/s41598-025-02963-3DOI Listing

Publication Analysis

Top Keywords

dynamic conditions
12
blood pressure
8
pressure estimation
8
cuffless estimation
8
utransbpnet cuffless
4
cuffless calibration-free
4
calibration-free blood
4
estimation
4
dynamic
4
estimation dynamic
4

Similar Publications